• 제목/요약/키워드: Size Distribution Function

Search Result 598, Processing Time 0.028 seconds

Wave dispersion analysis of rotating heterogeneous nanobeams in thermal environment

  • Ebrahimi, Farzad;Haghi, Parisa
    • Advances in nano research
    • /
    • v.6 no.1
    • /
    • pp.21-37
    • /
    • 2018
  • In the present article, wave dispersion behavior of a temperature-dependent functionally graded (FG) nanobeam undergoing rotation subjected to thermal loading is investigated according to nonlocal strain gradient theory, in which the stress numerates for both nonlocal stress field and the strain gradient stress field. The small size effects are taken into account by using the nonlocal strain gradient theory which contains two scale parameters. Mori-Tanaka distribution model is considered to express the gradually variation of material properties across the thickness. The governing equations are derived as a function of axial force due to centrifugal stiffening and displacements by applying Hamilton's principle according to Euler-Bernoulli beam theory. By applying an analytical solution, the dispersion relations of rotating FG nanobeam are obtained by solving an eigenvalue problem. Obviously, numerical results indicate that various parameters such as angular velocity, gradient index, temperature change, wave number and nonlocality parameter have significant influences on the wave characteristics of rotating FG nanobeams. Hence, the results of this research can provide useful information for the next generation studies and accurate deigns of nanomachines including nanoscale molecular bearings and nanogears, etc.

A Study on an Electrical Biosignal Detection System for the Microbiochip (마이크로바이오칩의 전기신호검출 시스템에 관한 연구)

  • Park Jeong Yeon;Park Jae Jun;Kwon Ki Hwan;Cho Nahm Gyoo;Ahn Yoo Min;Lee Seoung Hwan;Hwang Seung Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.181-187
    • /
    • 2005
  • In this study, a microchip system fabricated with MEMS technology was developed to detect bioelectrical signals. The developed microchip using the conductivity of gold nanoparticles could detect the biopotential with a high sensitivity. For designing the microchip, simulations were performed to understand the effects of the size and number of nanoparticles, and the sensing width between electrodes on the detection of biosignals. Then, a series of experiment was performed to validate the simulation results and understand the feasibility of the proposed microchip design. Both simulation and experimental results showed that as the sensing width between electrodes increased the conductivity decreased. Also, the conductivity increased as the density of gold nanoparticles increased. In addition, it was found that the conductivity that changes with the nanoparticles density could be approximated by a cumulative normal distribution function. The developed microchip system could effectively apply when a biosignals should be measured with a high sensitivity.

Statistical comparison of morphological dilation with its equivalent linear shift-invariant system:case of memoryless uniform soruces (무기억 균일 신호원에 대한 수리 형태론적인 불림과 등가 시스템의 통계적 비교)

  • 김주명;최상신;최태영
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.79-93
    • /
    • 1997
  • This paper presents a linear shift-invariant system euqivalent to morphological dilation for a memoryless uniform source in the sense of the power spectral density function, and comares it with dialtion. This equivalent LSI system is found through spectral decomposition and, for dilation and with windwo size L, it is shown to be a finite impulse response filter composed of L-1 delays, L multipliers and three adders. Th ecoefficients of the equivalent systems are tabulated. The comparisons of dilation and its equivalent LSI system show that probability density functions of the output sequences of the two systems are quite different. In particular, the probability density functon from dilation of an independent and identically distributed uniform source over the unit interval (0, 1) shows heavy probability in around 1, while that from the equivalent LSI system shows probability concentration around themean vlaue and symmetricity about it. This difference is due to the fact that dilation is a non-linear process while the equivalent system is linear and shift-ivariant. In the case that dikation is fabored over LSI filters in subjective perforance tests, one of the factors can be traced to this difference in the probability distribution.

  • PDF

Three Dimensional Finite Element Analysis of Kimplant (Kimplant에 관한 3차원 유한요소 분석적 연구)

  • Kim, Woo-Uoung;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.9-17
    • /
    • 2004
  • In this study, the biomechanical characteristics of Kimplant were compared with that of Branemark implant by using three dimensional finite element analysis. Two finite element models were fabricated by inserting each implant into the bone model. The bone model was designed to have 18mm height, 13mm width and 15mm length. The size of each implant was planned to have 4mm width and 10mm length. A 200N force was applied on the center of abutment top in three directions - vertical, horizontal and oblique. After analyzing the stresses of fixture and surrounding bone, following results were obtained. 1. There was similar stress distribution between the two models. 2. The magnitude of maximum principal stress on the implant was similar between the two models but the location of maximum principal stress on the implant was different. 3. The magnitude and location of maximum principal stress on the surrounding bone was similar between the two models.

A Diffusion-based Model Theory of Passive-Targeted Drug Delivery in Solid Tumors (단단한 종양 안에 수동 조준된 약물의 전달에 관한 확산에 기초한 모델 이론)

  • Choi, Joon-Hyuck;Kang, Nam-Lyong;Choi, Sang-Don
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.161-166
    • /
    • 2007
  • A model theory of passive-targeted drug delivery in sphere-shaped solid tumors is introduced on the basis of Fick's law of diffusion, with appropriate boundary and initial conditions. For a uniform initial concentration inside the tumor, the concentration is obtained as a function of time and radial position. The concentration is shown to approach the equilibrium distribution as the time elapses, as is expected by the Gedanken Experiment. The time-evolution rate is found to be determined by the diffusion coefficient of the drug in the tissue, the size of the tumor, the volume of the drug-injected region, and the concentration gradient at the boundary.

  • PDF

Gene Targeting of the Acyl-CoA Synthetase Specific to Arachidonate

  • Kang, Man-Jong
    • Proceedings of the KSAR Conference
    • /
    • 2000.10a
    • /
    • pp.3-4
    • /
    • 2000
  • The synthesis of acyl-CoA catalyzed by acyl-CoA synthetase (ACS, EC 6.2.1.3) from fatty acid, ATP, and CoA is a crucial reaction in mammalian fatty acid metabolism. In arachidonate metabolism, acyl-CoA synthetase(ACS) plays a key role in the esterification of free arachidonate into membrane phospholipids. Following its release by the action of calcium dependent phospholipase, free arachidonate is believed to be rapidly converted to arachidonoyl-CoA and reesterified into phospholipids in order to prevent excessive synthesis of eicosanoids. In previous studies, we have characterized five ACSs (designated as ACS1-5) with different tissue distribution. ACS1, ACS2, and ACS5 are similar in structure and fatty acid preference, and completely different from ACS3 and ACS4. The latter are arachidonate-preferring enzymes closely related in structure but expressed in different tissues: ACS3 mRNA is highly expressed in the brain and the mRNA for ACS4 is expressed in steroidogenic tissues including adrenal gland, ovary, and testis. To learn more about the potential function of ACS4 in arachidonate metabolism, we have produced knock-out mice for ACS4 gene. ACS4+/- females become pregnant less frequently and produce small litters with extremely low transmission of the disrupted alleles. Striking morphological changes including extremely enlarged uterine filled with numerous proliferative cysts of various size were detected in ACS4+/- females. Furthermore, marked accumulation of prostaglandins were seen in the uterus of heterozygous females. These results indicate that ACS4 is critical for the uterine arachidonate metabolism and heterozygous disruption of its gene lead to impaired pregnancy.

  • PDF

Synthesis and Characterization of Nickel Powders by a Solvothermal Processing (용매열 합성법에 의한 니켈 분말 합성 및 특성)

  • Park, Chan;Bae, Dong-Sik
    • Korean Journal of Materials Research
    • /
    • v.26 no.5
    • /
    • pp.246-249
    • /
    • 2016
  • Nickel powders were prepared under solvothermal condition by precipitation from metal nitrates with aqueous ammonium hydroxide. The powders were obtained at in a temperature range of $190-250^{\circ}C$ for 6h. The morphology and size of nickel powders were studied as a function of reaction temperature. The synthesis of nickel crystalline particles is possible under a solvothermal conditions in ethylene glycol solution. Characterization of the synthesized nickel powders were studied by XRD, SEM(FE-SEM) and TG/DSC. X-ray diffraction analysis of the synthesized powders indicated the formation of nickel structure after reaction. The average crystalline sizes of the synthesized nickel powders were in the range of 200-1000 nm; and the distribution of the powders was broad. The shape of the synthesized nickel particles was almost spherical. The morphology of synthesized nickel powders changed with reaction condition. It was possible to synthesize nickel powders directly in ethylene glycol without reducing agent.

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

Improvement of Image Compression Using Quantization Technique in Computed Tomography Images (CT영상에서 양자화기법을 이용한 영상압축의 개선)

  • Park, Jae-Hong;Yoo, Ju-Yeon;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.505-510
    • /
    • 2018
  • In this study, we allocate bits by quantizing these fractal coefficients through a quantizer which can extract the probability distribution. In the coding process of IFS, a variable size block method is used to shorten the coding time and improve the compression ratio. In the future, it will be necessary to further improve the coding time and the compression rate while maintaining the best image quality in the fractal coding process.

Briquetting of Waste Silicon Carbide Obtained from Silicon Wafer Sludges (실리콘 wafer sludge로부터 얻어진 SiC의 단광화 기술)

  • Koo, Seong Mo;Yoon, Su Jong;Kim, Hye Sung
    • Journal of Powder Materials
    • /
    • v.23 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • Waste SiC powders obtained from silicon wafer sludge have very low density and a narrow particle size distribution of $10-20{\mu}m$. A scarce yield of C and Si is expected when SiC powders are incorporated into the Fe melt without briquetting. Here, the briquetting variables of the SiC powders are studied as a function of the sintering temperature, pressure, and type and contents of the binders to improve the yield. It is experimentally confirmed that Si and C from the sintered briquette can be incorporated effectively into the Fe melt when the waste SiC powders milled for 30 min with 20 wt.% Fe binder are sintered at $1100^{\circ}C$ upon compaction using a pressure of 250 MPa. XRF-WDS analysis shows that an yield of about 90% is obtained when the SiC briquette is kept in the Fe melt at $1650^{\circ}C$ for more than 1 h.