• 제목/요약/키워드: Site installation resistance test

검색결과 14건 처리시간 0.03초

기성말뚝의 지지력 거동해석과 시공관리방안 (Bearing Capacity and Control Method of Driven Piles)

  • 박영호;김경석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 1999
  • Dynamic load and static load tests are performed on steel pipe piles and concrete piles at five construction sites in highway to compare the difference of load bearing mechanisms. At each site, one steel pile is instrumented with electric strain gages and dynamic tests are performed on the pile during installation. Damages of strain gages due to the installation are checked and static test is performed upon the same pile after two or seven days as well. It shows that load transfer from side friction to base resistance behaves somewhat differently according to the results of load-settlement analysis obtained from PDA and static load test. Initial elastic stage of load settlement curves of two load tests is almost similar. But after the yielding point, dynamic resistance of pile behaves more stiffer than static resistance, thus, dynamic load test result might overestimate the real pile capacity compared with static result. Analysis of gage readings shows that unit skin friction increases exponentially with depth. The skin friction is mobilized at the 1∼2m above the pile tip and contributes to the considerable side resistance. Comparison of side and base resistances between the measured value and the calculated value by Meyerhof's bearing capacity equation using SPT N value shows that the calculated base resistance is higher than the measured. Therefore, contribution of side resistance to total capacity shouldn't be ignored or underestimated. Finally, based upon the overall test results, a construction control procedure is suggested.

  • PDF

장기성능 평가를 위한 토목섬유 화학저항성 시험 고찰 (Consideration of Geosynthetics Chemical Resistance Test for Long-Term Performance Evaluation)

  • 전한용;장연수
    • 한국지반공학회논문집
    • /
    • 제25권7호
    • /
    • pp.55-64
    • /
    • 2009
  • 본 연구에서는 실제 현장조건을 고려하여 토목섬유의 화학저항성을 측정하기 위한 개선된 시험방법이 제안되었다. 이를 위하여 시공조건에 가장 근접한 시험법을 규격화하기 위한 인덱스 및 성능시험이 실시되었으며, Arrhenius 식에 의한 가속모델을 적용하여 실험 데이터를 해석하였다. 전반적인 실험 결과를 분석, 비교하여 현장 시공조건에 부합한 개선된 토목섬유의 화학저항성 시험방법을 확립하고 그 가능성을 제시하였다.

보강토 옹벽용 지오그리드의 현장 내시공성 및 강도 감소계수 평가에 관한 연구 (A Study on the Evaluation of Field Installation Damage and Strength Reduction Factor of Geogrid for Reinforced Retaining Wall)

  • 박주환;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권7호
    • /
    • pp.5-12
    • /
    • 2012
  • 최근 국내에서 기존 RC옹벽보다 시공실적이 증가하고 있는 보강토 옹벽은 보강자재, 시공방법, 전면블럭의 형태에 따라 다양하지만 공법에 대한 안전성이 충분히 검증되지 않아 설계와 시공관리에 어려움이 많으며, 보강토 옹벽에 사용되는 보강재 등은 제조사별로 규격과 형상이 다양하고 영세한 업체에서 제작하였거나 일부 값이 싼 품질이 낮은 제품이 수입되고 있지만 이를 설계에 적용할 수 있는 적절한 기준이 제시되지 못하고 있는 실정이다. 이에 본 연구는 보강토 옹벽의 보강재인 옹벽용 그리드에 대하여 현장 내시공성 시험을 통해 다양한 형태의 옹벽용 그리드의 내시공성 감소계수를 제안하고, 국내외 연구결과 분석과 국내 시판되고 있는 제조사별로 제시한 옹벽용 그리드의 물성치를 조사 분석하였다. 결론적으로, 뒤채움재의 입경과 모난 정도의 차이, 입도 분포에 따라 감소계수에 미치는 영향이 크므로 일정규모 이상의 현장에서는 현장내시공성 시험을 거쳐 뒤채움재 별로 차별화된 감소계수를 적용하고, 보강벽체의 활용성에 따라 연성과 강성그리드를 잘 선정하여 적용함으로서 효과적으로 보강토 옹벽의 안전성을 높일 수 있음을 확인하였다.

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

양방향말뚝 재하시험을 통한 현장타설말뚝의 연직지지력 설계정수 산정 (Evaluation of Design Parameters for Axial Bearing Capacity of Drilled Shafts by Bi-directional Loading Tests)

  • 정경자;조종석;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.574-584
    • /
    • 2006
  • Bi-directional loading test data are available to evaluate the design parameters which reflect the characteristics of a construction method and the variations of ground at the site where drilled shafts are installed. The method to obtain the design parameters of a real bridge by hi-directional loading test was introduced. The plans of multi-level testing and installation of measuring instruments should be made according to the rough estimation of axial bearing capacity, the length of pile, and the construction method. While the relationship between end bearing resistance and displacement was obtained directly from the hi-directional loading test, the relationship between unit side resistance and displacement was calculated through the measuring values. 1% displacement of pile diameter was adopted as the criteria of failure for ultimate resistance. As the settlement of pile head at the total ultimate bearing capacity obtained from these method was less than 1.5 % of pile diameter, this method was conservative to use in the field.

  • PDF

Precast Concrete Panel을 사용한 슬라브궤도 시험시공에 대한 평가 (Evaluation for the Test Installation of Slab Track by Using Precast Concrete Panels)

  • 김순철;공선용;강정옥;이종민;한광섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1071-1077
    • /
    • 2004
  • This paper is presenting the performance evaluation on the installed concrete panels. As a result of the evaluation, the resistance to track displacement of temporary support structure was improved and it resulted in the improvement of work stability during installation. And, by the application of new technology and the saving of concrete consumption, both workability and cost were improved and, therefore, the shorter project period and cost saving can be expected. Furthermore, as a result of noise & vibration measurement at site, it has shown good effects of anti-noise and anti-vibration. In conclusion, this process was proved as very effective for track improvement.

  • PDF

전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향 (Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method)

  • 이복희;어주홍;김성원
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.97-104
    • /
    • 2001
  • 본 논문에서는 전위강하법에 의한 접지저항 측정시 전위보조전극 위치의 영향에 대하여 기술하였다. 전위강하법에서 접지저항은 이론적으로 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬때 61.8[%]법칙을 적용하여 측정한다. 하지만 측정현장의 사정상 전위보조전극의 위치를 피측정 접지전극과 전류 보조전극이 이루는 일직선과 어느 정도의 각도를 가지도록 시설하여 접지저항을 측정하게 될 경우에 측정오차가 발생하게 되고 보정이 필요하다. 본 연구에서의 측정대상 전극은 길이 2.4 [m]의 봉형 접지전극으로 하였으며, 피측정 접지전극, 전위보조전극, 전류보조전극이 일직선상에 놓이지 않은 상태에서 접지저항을 측정하면 측정값은 항상 (-)의 오차를 나타내었고, 이들 전극이 이루는 각도가 증가함에 따라 측정 오차도 증가하였다.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도와 보어홀 열저항에 미치는 영향 (The Effects of the Installation Conditions of Ground Loop Heat Exchanger to the Thermal Conductivity and Borehole Resistance)

  • 임효재;공형진;강성재;최재호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.95-102
    • /
    • 2011
  • A ground loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. A proper design requires certain site specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U tube configurations on ground effective thermal conductivity and borehole thermal resistance. In this study, thermal response tests were conducted using a testing device to 9 different ground loop heat exchangers. From the experimental results, the length of ground loop heat exchanger affects to the effective thermal conductivity. The results of this experiment shows that higher thermal conductivity of grouting materials leads to the increase effective thermal conductivity from 22 to 32%. Also, mounting spacers have increased by 14%.

직류급전시스템 고장점표정장치 개발을 위한 현장시범 설치 (D.C. Power system Failure Point Informing Device Development of Face Trial for the Site Installation)

  • 김윤식;김용덕;하태요;한문섭;박종국;임형길
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2011-2014
    • /
    • 2011
  • A "failure point informing device" is that if a accident of short or ground occurs in electric railway it inform us of the distance to accident point. SeoulMetro, KRRI, 2ISYS have developed this device and installed in line no.4 substation Iy-Chon, Sam-Gakgi to test its performance. A line resistance will be measured to test this device in November.

  • PDF

전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향 (Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method)

  • 이복희;엄주홍
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.69-77
    • /
    • 2000
  • 본 논문에서는 찬우$\mid$강하법에 의한 접지저항 및 대지첸위 분표의 측캠시 전휴보조전극의 영향에 대하여 기술하였으며, 측정시 오치를 최소화하는 기법을 제안하였다. 전위강해법은 전위와 천류의 측정에 이론적인 비1깅을 두고 있으며, 측정오차는 주로 측정시 설치하는 보조전극의 위치와 자체저항에 기인한다. 피측정 접지전극의 접지저항은 전위강하법에서 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬 때 61.8[%]법칙을 적용하여 측정한다. 하지만 건물이나 포장도로, 구조물 등이 산재해 있는 도심의 경우에는 현장에서 피측정 접지전극과 전류보조전극 사이에 적결한 이격거리 확보가 불가능하거냐 전류보조전극의 접지저행값이 피측정 챔 지전극에 비하여 큰 값을 가지는 경우가 있다. 파측정 접지천극과 전류보조전극을 충분히 이격시키지 않거나 전류류보조전극의 접지저항값이 피측청 접지전극의 접지저항보다 비정상척으로 큰 경우 접지저항의 측정은 오차를 수반하게 되며, 측정된 접지저항값은 오차즐 보정해 주어야 한다. 본 연구애서 측정대상 전극은 길이 2.4[m]의 봉형 접지전극으호 하였으며, 전류보조전극의 영향을 고려할 때 피측정 접지전극과 전류보조전극의 적정한 이격거리는 피측정 접치전극 길이의 5배 이상으로 하여야 전위보조전극을 사설하기가 용이하며 측정정확도의 확보에 유리하다. 또한 전류보존전극의 접지저항값이 피측정 접지전극의 접지저항값 약 36.5배 이하에서는 거의 오차를 발생시키지 않는다.

  • PDF