• Title/Summary/Keyword: Single-tooth dental implants

Search Result 49, Processing Time 0.04 seconds

Masticatory function following implants replacing a second molar

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • Purpose: The aim of this study was to obtain objective and standardized information on masticatory function and patient atisfaction following second molar single implant therap. Methods: Twenty adult patient, who had restored second molar single implants more than 1 month before the study, were enrolled in this stud. All patients received a chewing test using peanuts before and after insertion of the implant prosthesi, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therap. Results: his study obtained standardized information on the masticatory function objectively (e.g., P, R, $X_{50}$) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from $67.8{\pm}9.9$ to $84.3{\pm}8.5$% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size ($X_{50}$) of Post-insertion is lower than that of Preinsertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. Conclusions: These findings indicate that a second molar single implant can increase masticatory function.

Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods (임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도)

  • Cha, Ji-Ae;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.175-182
    • /
    • 2017
  • From March 1, 2016 to August 31, 2016, 375 dental implant patients between the ages of 30 and 70 years to evaluate their subjective symptoms and satisfaction according to prosthesis methods. The collected data were analyzed using the chi-square distribution test, t-test, one-way analysis of variance, and multiple logistic regression. Of the patients with subjective symptoms of peri-implantitis, 40.5% reported food impaction, 49.1% reported bleeding, 61.1% reported pain, 61.9% reported halitosis, and the overall satisfaction level with the implants was 3.95 points. In the prosthesis methods, implant-teeth connective group showed the lowest level of the food impaction (21.3%), the pain (35.5%), and the halitosis (36.6%) (p<0.001), and the lowest bleeding was the implant single (33.8%) (p<0.05). Patient satisfaction was higher in the implant-teeth connective group (4.06 points) and the group without bone grafting (4.03 points) (p<0.01). Factor analysis showed that implant satisfaction was 0.43 times lower in the single implant group and 0.44 times lower in the implant-implant connective group than in the implant-teeth connective group. As a result of the study, it is expected that the method of extending the life of adjacent teeth and restoring the function of the tooth defect region is an implant-teeth connection method, so that it can be utilized positively through various clinical studies.

Retrospective studies of dental implant placement at each intraoral site and situation (임플란트 식립 유형에 따른 후향적 연구)

  • Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chae, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

A study on the micromotion between the dental implant and superstructure (임플란트와 상부구조물 사이의 micromotion에 관한 연구)

  • Kim, Ji-Hye;Song, Kwang-Yeob;Jang, Tae-Yeob;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

The Distribution of Implant Patients and the Type of Implant Site (임플란트 환자의 분포 및 식립부 유형)

  • Park, Ji-Eun;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Seong;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.4
    • /
    • pp.819-836
    • /
    • 2004
  • Nowdays, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The reason is that unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. So, It is needed understanding about the type, distribution of implant patient. The following results on patient type and implant distribution were compiled from 4433 implant cases of 1596 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2004. 1. There are no dissimilarities between men and women, with patients in their 40, 50s accounting for 52.5% of patients and 57.5% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 54.9% of implant treatments followed by Mx. posterior area(27.6%), Mx anterior area(11.9%) and Mn anterior area(5.6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 97.5% and fully edentulous patient accounted for the remaining 2.5%. 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. In the distribution of bone quality for maxillae, type III was most, followed by type II, r type IV and r type I. As for mandible, type II was most, followed by type III, type IV and for type I. 6. In the distribution of bone quantity for maxillae, type C was most, followed by type B, type D, type A, and for type E. As for mandible, type B was 52% most, followed by type C, type D, type A and type E. 7. The majority of implants were those of 1O-14mm in length (85.2%) and regular diameter in width (64%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

The Study of Implant Patient's Type and Implant Distribution (임플란트 환자의 유형 및 분포에 대한 연구)

  • Hong, Sung-Jae;Paik, Jeong-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.539-554
    • /
    • 2002
  • It has been approximately 40 years since $Br{{\aa}}nemark$ first introduced osseo-integration for implants in the early 1960s. Unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. Thus, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The following results on patients type and implant distribution were compiled from 1814 implant cases of 640 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2001. 1. There are no dissimilarities between men and women, with patients in their 40,50s accounting for 49% of patients and 56% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 59% of implant treatments followed by Mx. posterior area(21%), Mx anterior area(l4%) and Mn anterior area 2%. 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 98% and fully edentulous patient accounted for the remaining 2% 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Compared to women, men are more likely to suffer from tooth loss due to periodontal disease. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. The distribution of bone quality for maxillae was 52% for type III, followed by 23% for type II, 20% for type IV and 0% for type I. As for mandible, the distribution was 52% for type II, followed by 37% for type III, 7% for type IV and 4% for type I. 6. The distribution of bone quantity for maxillae was 49% for type C, followed by 34% for type B, 14% for type D, 3% for type A, and 0% for type E. As for mandible, the distribution was 52% for type B, followed by 35% for type C, 6% for type D, 3% for type A and 0% for type E. 7. The majority of implants were those of 10-14mm in length (80%) and regular diameter in width (79%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS (Steri-Oss 임플랜트의 임상 결과에 관한 연구)

  • Min, Young-Kyu;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

How can improve the insufficient success rate at immediate loading? (임상가를 위한 특집 1 - Immediate loading 부족한 성공률 5% 채우기)

  • Jun, Sang-Ho;Ahn, Jin-Soo;Ryu, Jae-Jun;Kwon, Jong-Jin
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.190-197
    • /
    • 2013
  • A titanium based screw shaped dental implant was first introduced by Branemark and a treatment protocol where the restoration of edentulous area by connecting abutment after the osseointegration of the titanium surface of the implant and surrounding bone structure has been proposed. Although this protocol is widely accepted as a standard up to date, the healing duration of 3-6 months as well as the need for provisional prostheses during this period present as a major drawback. Immediate loading has been accomplished through the advent of various implant designs, enforced surface treatments, diverse forms of abutment, and delicate surgical techniques together with the increase in demand from the patients. The success rate of the immediate loading technique has been first reported as 85.7% by Dr. Schnitman in 1990 which recently has been reported up to 100% in the case of immediate loading in single tooth by Dr. Kan. To ameliorate the success rate of immediate loading technique, selection of patients presenting a sound bone quality and quantity, acquiring primary stability through delicate surgical techniques and fabrication of prostheses which accounts for biological stabilities should all be taken into consideration. This presentation introduces the understanding of biological stability of immediate loading, various methods for measurement of stability and clinical cases regarding immediate loading technique.