Browse > Article
http://dx.doi.org/10.4047/jkap.2021.59.1.126

Axial displacement in single-tooth implant restoration: Case report  

Jeong, Seung-Hoe (Department of Prosthodontics, Gangnam Severance Dental Hospital, College of Dentistry, Yonsei University)
Kim, Sunjai (Department of Prosthodontics, Gangnam Severance Dental Hospital, College of Dentistry, Yonsei University)
Chang, Jae-Seung (Department of Prosthodontics, Gangnam Severance Dental Hospital, College of Dentistry, Yonsei University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.59, no.1, 2021 , pp. 126-133 More about this Journal
Abstract
Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.
Keywords
Axial displacement; Infraposition; Internal connection; Intraoral scan; In vivo;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. J Oral Rehabil 2006;33:75-8.   DOI
2 Khraisat A, Stegaroiu R, Nomura S, Miyakawa O. Fatigue resistance of two implant/abutment joint designs. J Prosthet Dent 2002;88:604-10.   DOI
3 Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-26.
4 Bozkaya D, Muftu S. Mechanics of the tapered interference fit in dental implants. J Biomech 2003;36:1649-58.   DOI
5 Lemos CAA, Verri FR, Bonfante EA, Santiago Junior JF, Pellizzer EP. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis. J Dent 2018;70:14-22.   DOI
6 Dailey B, Jordan L, Blind O, Tavernier B. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque. Int J Oral Maxillofac Implants 2009;24:251-6.
7 Seol HW, Heo SJ, Koak JY, Kim SH, Han CH. Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study. J Korean Acad Prosthodont 2013;51:315-22.   DOI
8 Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
9 Kim KS, Lim YJ, Kim MJ, Kwon HB, Yang JH, Lee JB, Yim SH. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection. Clin Oral Implants Res 2011;22:834-9.   DOI
10 Kim SJ, Son K, Lee KB. Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study. J Adv Prosthodont 2018;10:388-94.   DOI
11 Lee JH, Kim DG, Park CJ, Cho LR. Axial displacements in external and internal implant-abutment connection. Clin Oral Implants Res 2014;25:e83-9.   DOI
12 Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002;28:67-73.   DOI
13 Hyeon JM, Park JM, Kim SK, Koak JY, Heo SJ. A quantitive analysis of settling effect in internal tapered connection implants after cyclic loading using 858 Bionix II. Korean Acad Oral Maxillofac Implantology 2015;19:2-9.
14 Polymeri A, Li Q, Laine ML, Loos BG, Wang HL. Occlusal migration of teeth adjacent to implant prostheses in adults: A long-term study. Int J Oral Maxillofac Implants 2020;35:342-9.   DOI
15 Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.
16 Jemt T. Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. Clin Oral Implants Res 1994;5:142-7.   DOI
17 Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.   DOI