1 |
Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. J Oral Rehabil 2006;33:75-8.
DOI
|
2 |
Khraisat A, Stegaroiu R, Nomura S, Miyakawa O. Fatigue resistance of two implant/abutment joint designs. J Prosthet Dent 2002;88:604-10.
DOI
|
3 |
Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-26.
|
4 |
Bozkaya D, Muftu S. Mechanics of the tapered interference fit in dental implants. J Biomech 2003;36:1649-58.
DOI
|
5 |
Lemos CAA, Verri FR, Bonfante EA, Santiago Junior JF, Pellizzer EP. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis. J Dent 2018;70:14-22.
DOI
|
6 |
Dailey B, Jordan L, Blind O, Tavernier B. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque. Int J Oral Maxillofac Implants 2009;24:251-6.
|
7 |
Seol HW, Heo SJ, Koak JY, Kim SH, Han CH. Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study. J Korean Acad Prosthodont 2013;51:315-22.
DOI
|
8 |
Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
|
9 |
Kim KS, Lim YJ, Kim MJ, Kwon HB, Yang JH, Lee JB, Yim SH. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection. Clin Oral Implants Res 2011;22:834-9.
DOI
|
10 |
Kim SJ, Son K, Lee KB. Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study. J Adv Prosthodont 2018;10:388-94.
DOI
|
11 |
Lee JH, Kim DG, Park CJ, Cho LR. Axial displacements in external and internal implant-abutment connection. Clin Oral Implants Res 2014;25:e83-9.
DOI
|
12 |
Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002;28:67-73.
DOI
|
13 |
Hyeon JM, Park JM, Kim SK, Koak JY, Heo SJ. A quantitive analysis of settling effect in internal tapered connection implants after cyclic loading using 858 Bionix II. Korean Acad Oral Maxillofac Implantology 2015;19:2-9.
|
14 |
Polymeri A, Li Q, Laine ML, Loos BG, Wang HL. Occlusal migration of teeth adjacent to implant prostheses in adults: A long-term study. Int J Oral Maxillofac Implants 2020;35:342-9.
DOI
|
15 |
Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.
|
16 |
Jemt T. Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. Clin Oral Implants Res 1994;5:142-7.
DOI
|
17 |
Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
DOI
|