• Title/Summary/Keyword: Single use device

Search Result 233, Processing Time 0.028 seconds

An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter (단상 계통연계 인버터를 위한 개선된 고조파 보상법)

  • Khan, Reyyan Ahmad;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.

A SiGe HBT of Current Gain Modulation By using Passivation Ledge (Passivation Ledge를 이용한 SiGe HBT의 Current Gain Modulation)

  • You, Byoung-Sung;Cho, Hee-Yup;Ku, Youn-Seo;Ahn, Chul
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.771-774
    • /
    • 2003
  • Passivation Ledge's device is taken possession on one-side to the Emitter in this Paper. contact used in this paper Pt as Passivation Ledge of device to use Schottky Diode which has leitmotif, It is accomplished Current Modulation that we wish to do purpose using this device. Space Charge acts as single device which is becoming Passivation to know this phenomenon. This device becomes floating as well as Punched-through. V$_{L}$ (Voltage for Ledge) = - 0.5V ~ 0.5V variable values , PD(Partially Depleted ; Λ>0), as seeing FD(Fully Depleted ; A = 0) maximum electric current gains and Gummel Plot of I-V characteristics (V$_{L}$ = 0.1/ V$_{L}$ = -0.1 ). Becomming Degradation under more than V$_{L}$ = 0.1 , less than V$_{L}$ =-0.05 and Maximum Gain(=98.617076 A/A) value in the condition V$_{L}$ = 0.1. A Change of Modulation is electric current gains by using Schottky Diode and Extrinsic Base PN Diode of Passivation Ledge to Emitter Depletion Layer in HBT of Gummel-Poon I-V characteristics and the RF wide-band electric current gains change the Modulation of CE(Common-Emitter) amplifier description, and it had accomplished Current Gain Modulation by Ledge Bias that change in high frequency and wide bands. wide bands.s.

  • PDF

Functional disposable use flow tube converting the respiratory air flow rate into averaged dynamic pressure (호흡기류를 동압력으로 변환하는 기능성 일회용 호흡관)

  • Kim, Kyung-Ah;Kim, Hyun-Shik;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.125-131
    • /
    • 2002
  • Respiratory air flow rate is necessarily measured for the pulmonary function evaluation. The currently used devices are exposed to the problems of measurement reliability and cross-patient infection. The present study introduced a new technique which converted the bidirectional air flow rate into averaged dynamic pressure based on the famous Bernoulli's energy conservation principle. Single use plastic sensing element was assembled within the flow tube(mouth piece) made of paper, which was named "functional single use flow tube". Experiment demonstrated only ${\pm}1.5%$ relative error in the standard 3L volume measurement procedure well within the error limit suggested by the American Thoracic Society(ATS). Disposable use design completely eliminated cross-patient infection. The present device is best useful and safe for clinical respiratory air flow measurement such as spirometry.

Algorithm to cope with SEUs(Single Event Upsets) on STSAT-1 OBC(On-board Computer) (과학기술위성 1호 탑재 컴퓨터(On-board Computer)에서의 SEUs(Single Event Upsets) 극복 알고리즘)

  • Chung, Sung-In;Park, Hong-Young;Lee, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.10-16
    • /
    • 2008
  • Generally, the satellite circling round in a low orbit goes through Van Allen belt connecting with the magnetic fold, in which electronic components are easily damaged and shortened by charged particles moving in a cycle between the South Pole and the North Pole. In particular, Single Event Upset(SEU) by radiation could cause electronic device on satellite to malfunction. Based on the idea mentioned above, this study considersabout SEU effect on the On-board Computer(OBC) of STSAT-1 in the space environment radiation, and shows algorithm to cope with SEUs. In this experiment, it also is shown that the repetitive memory read/write operation called memory wash is needed to prevent the accumulation of SEUs and the choice for the period of memory wash is examined. In conclusion, it is expected that this research not only contributes to understand low capacity of On-board Computer(OBC) on Low Earth Orbit satellite(LEOS) and SaTReC Technology satellite(STSAT) series, but also makes good use of each module development of Korea Multi-Purpose Satellite(COMPSAT) series.

A New Device for Intrauterine Artificial Insemination in the Dog

  • Kong, I.K.;Yu, D.J.;Jeong, S.R.;Oh, I.S.;Yang, C.J.;Cho, S.G.;Bae, I.H.;Oh, D.H.;Kim, H.R.;Cho, S.K.;Park, C.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.180-184
    • /
    • 2003
  • The intrauterine inseminator (IUI) was developed to provide the method of depositing dog semen into the uterine body instead of the vagina. The IUI consists of a vaginal endoscope, a balloon sheath, and injection catheter. When the endoscope is inserted into the vagina and the balloon expanded with air, the cervical os becomes visible so a injection catheter can be inserted through the cervix for deposition of the frozen-thawed semen. The efficacy of the IUI device was compared to intra-vaginal artificial insemination using semen that had been collected and frozen from pooled sperm-rich fraction of ejaculates collected from two Jindo dog donors. Aliquots of semen were extended with a Tris-egg yolk diluent, centrifuged, the seminal plasma removed, the pellet resuspended with the same diluent, and cooled to $5^{\circ}C$ over a 2 h period. A Tris-egg yolk-glycerol extender was added at $5^{\circ}C$; after 1 h, semen was loaded into 0.5 ml straws, and straws were frozen in LN vapor for 5 min, and immersed in LN for storage. The final sperm concentration for freezing was approximately $100{\times}10^{6}cells/ml$. The straws were thawed at $70^{\circ}C$ for precisely 6 sec, 1.5 ml Tris-egg yolk buffer at $38^{\circ}C$ added, and the 2 ml of thawed semen was used for a single insemination using the IUI device. Each bitch was inseminated at optimal insemination point, which was estimated by vaginal epithelial cells staining and progesterone concentration analysis. Use of the IUI device resulted in 21 of 26 females giving birth to 89 pups ($4.2{\pm}1.6$ pups per litter), while intra-vaginal AI resulted in 6 of 15 females whelping a total of 17 pups ($2.8{\pm}1.2$ pups per litter). We believe the IUI device is easier to use than previously described devices used for intrauterine insemination. In our experience the expansion of the balloon has a calming effect on the bitch that aids the inseminator. These results indicate that the IUI device was able to provide high fertility with 50 million frozen sperm per insemination and two inseminations.

Development of monitoring device with thermal line sensors and its use for grouting and leakage problems (그라우팅과 누수 문제에 대처한 온도센서 배열 모니터링 장치 개발)

  • Kim, Jung-Yul;Honarmand, H.;Kim, Yoo-Sung;Nam, Ji-Yeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.509-516
    • /
    • 2004
  • The measurement of abnormal change of temperature(temperature anomaly) will help determine the safety of various engineering constructions, as the measurement in body often used to diagnose one's health. Temperature anomaly can be occurred in leakage or seepage of water flow in rocks, and in ground water table etc. Grouting materials injected in fractured rocks generate heat during hardening process. The degree of temperature change is associated directly with heat flow characteristics, that is, thermal conductivity, specific heat capacity. density of the surrounding rocks and can afford to assess the grouting efficiency. However, in practice, the use of traditional temperature measuring technique composed of only one single thermal sensor has been fundamentally limited to acquire thermal data sufficient to use for that, partly due to the time-consuming measuring work, partly due to the non-consecutive quality of data. Thus, in this paper, a new concept of temperature measuring technique, what we call, thermal line sensor technique is introduced. In this, the sensors with an accuracy of $0.02^{\circ}$ are inserted at regular intervals in one line cable and addressed by a control device, which enables to fundamentally enhance the capability of data acquisition in time and space. This new technology has been demonstrated on diverse field model experiments. The results were simply meant to be illustrative of a potential to be used for various kinds of temperature measurements encountered in grouting and leakage problems.

  • PDF

Realization of single supply to reduce power on portable radiation detection device (소모전력 감소를 위한 단일 전원 휴대용 방사선 검출장치 구현)

  • Oh, Jae-Kyun;Nam, Hye-Jin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.1024-1030
    • /
    • 2015
  • Safety and security system have been internationally enhanced in a field of shipping logistics. Accordingly, techniques for safety and security have been studied steadily. The need of portable radiation detection device is increasing by the search of the container is enhanced. In this paper, we propose a study to improve the life of the system and the realization of portable radiation detection device based on Cortex-A9. Configuration of a portable radiation detection device is configured largely to an analog board and the digital platform and the sensor module. The power used in each stage of the analog board is varied. Uses a switching regulator to use various power supply thereby to generate an error result and cause the switching noise. It is proposed to reduce the power consumption reducing technique for the study.

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.

Mathematical Analysis for Efficiency of Eavesdropping Attack Using Directional Antenna in mmWave Band (밀리미터파 대역에서 지향성 안테나 사용에 의한 도청공격 대응 효율성의 수학적 분석)

  • Kim, Meejoung;Kim, Jeong Nyeo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.11
    • /
    • pp.1074-1077
    • /
    • 2013
  • This paper analyzes the benefit of using directional antennas against eavesdropping attack in millimeter wave (mmWave)-based networks. All devices are equipped with a directional antenna or an omni-directional antenna in a single-hop communications. The probability of a device being detected by an eavesdropper is analyzed based on the exposure region of a device. The relative detection rate is introduced to represent the benefit of using directional antenna. Numerical results show that there exists an optimal number of devices that maximizes the detection probability and it varies according to the parameters such as antenna beamwidth. It shows that the use of directional antenna enables to protect the devices from the detection by an eavesdropper for almost the whole situation in mmWave band communication.

Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations

  • Salvi, Jonathan;Rizzi, Egidio
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.231-256
    • /
    • 2016
  • This study concerns the derivation of optimum tuning formulas for a passive Tuned Mass Damper (TMD) device, for the case of benchmark ideal excitations acting on a single-degree-of-freedom (SDOF) damped primary structure. The free TMD parameters are tuned first through a non-linear gradient-based optimisation algorithm, for the case of harmonic or white noise excitations, acting either as force on the SDOF primary structure or as base acceleration. The achieved optimum TMD parameters are successively interpolated according to appropriate analytical fitting proposals, by non-linear least squares, in order to produce simple and effective TMD tuning formulas. In particular, two fitting models are presented. The main proposal is composed of a simple polynomial relationship, refined within the fitting process, and constitutes the optimum choice. A second model refers to proper modifications of literature formulas for the case of an undamped primary structure. The results in terms of final (interpolated) optimum TMD parameters and of device effectiveness in reducing the structural dynamic response are finally displayed and discussed in detail, showing the wide and ready-to-use validity of the proposed optimisation procedure and achieved tuning formulas. Several post-tuning trials have been carried out as well on SDOF and MDOF shear-type frame buildings, by confirming the effective benefit provided by the proposed optimum TMD.