• Title/Summary/Keyword: Single gamma

Search Result 654, Processing Time 0.03 seconds

A Study on the Calculation of Heat Release Rate to Compensate the Error due to Single Zone Assumption in Diesel Engines (단일 영역 모델 열발생율 계산 방법의 개선에 관한 연구)

  • Kim Ki-Doo;Yoon Wook-Hyeon;Ha Ji-Soo;Ryu Seung-Hyup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1063-1071
    • /
    • 2004
  • Accurate heat release analysis of cylinder pressure data is important for evaluating performance in the development of diesel engine However, traditional single zone first law heat release model(SZM) has significant limitations due to the simplified assumption of uniform charge and neglecting local temperature inside cylinder during combustion process. In this study. heat release rate based on single zone heat release model has been evaluated by comparison with computational analysis results using Fire code which is based on multi-dimensional model(MDM). To overcome limitations due to simplicity of single zone assumption. especially the influence of specific heat ratio on gross heat release has been esteemed and newly suggested were the equation $\gamma$= $\gamma$(${T/T}_{max}$) which describes the variations of gases thermodynamic properties with mean temperature and maximum mean temperature inside cylinder Single zone heat release model applied with this equation is shown to give very good results over whole range of operating conditions when compared with computational analysis results based on multi-dimensional model.

Splitting effect of photocurrent for $CdIn_2Te_4$ single crystal

  • You, Sang-Ha;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.84-85
    • /
    • 2009
  • The single crystals of p-$CdIn_2Te_4$ were grown by the Bridgman method without the seed crystal. From photocurrent measurements, it was found that three peaks, A, B, and C, correspond to the intrinsic transition from the valence band states of $\Gamma_7(A)$, $\Gamma_6(B)$, and $\Gamma_7(C)$ to the conduction band state of $\Gamma_6$, respectively. The crystal field splitting and the spin orbit splitting were found to be 0.2360 and 0.1119 eV, respectively, from the photocurrent spectroscopy. The temperature dependence of the $CdIn_2Te_4$ band gap energy was given by the equation of $E_g(T)=E_g(0)$ - $(9.43\times10^{-3})T^2$/(2676+T). $E_g(0)$ was estimated to be 1.4750, 1.7110, and 1.8229 eV at the valence band states of A, B, and C, respectively. The band gap energy of $p-CdIn_2Te_4$ at room temperature was determined to be 1.2023 eV.

  • PDF

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

Binding energy study from photocurrent signal in $CdIn_2Te_4$ crystal

  • Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.376-376
    • /
    • 2010
  • The single crystals of p-$CdIn_2Te_4$ were grown by the Bridgman method without the seed crystal. From photocurrent measurements, it was found that three peaks, A, B, and C, correspond to the intrinsic transition from the valence band states of $\Gamma_7$(A), $\Gamma_6$(B), and $\Gamma_7$(C) to the conduction band state of $\Gamma_6$, respectively. The crystal field splitting and the spin orbit splitting were found to be 0.2360 and 0.1119 eV, respectively, from the photocurrent spectroscopy. The temperature dependence of the $CdIn_2Te_4$ band gap energy was given by the equation of $E_g(T)=E_g(0)-(9.43{\times}10^{-3})T^2/(2676+T)$. $E_g$(0) was estimated to be 1.4750, 1.7110, and 1.8229 eV at the valence band states of A, B, and C, respectively. The band gap energy of p-$CdIn_2Te_4$ at room temperature was determined to be 1.2023 eV.

  • PDF

Photocurrent Study on the Splitting of the Valence Band and Growth of $CdIn_2Te_4$ Single Crystal by Bridgman method (Bridgman법에 의해 성장된 $CdIn_2Te_4$ 단결정의 가전자 갈라짐에 대한 광전류 연구)

  • Baek, Seung-Nam;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.347-351
    • /
    • 2003
  • A p-$CdIn_2Te_4$ single crystal has been grown by the Bridgman method without a seed crystal in a tree-stage vertical electric furnace. From photocurrent measurements, it was found that three peaks, A, B, and C, corresponded to an intrinsic transition due to the band-to-band transition from the valence band states ${\Gamma}_7(A),\;{\Gamma}_6(B),\;and\;{\Gamma}_7(C)$ to the conduction band state ${\Gamma}_6$, respectively. Also, the valence band splitting of the $CdIn_2Te_4$ crystal has been confirmed by photocurrent spectroscopy. The crystal field splitting and the spin orbit splitting were obtained to be 0.2360 and 0.1119 eV, respectively. Also, the temperature dependence of the band gap energy of the $CdIn_2Te_4$ crystal has been driven as the following equation of $E_g(T)\;=E_g(0)\;-\;(9.43\;{\times}\;10^{-3})T^2/(2676\;+\;T)$. In this equation, the Eg(0) was estimated to be 1.4750, 1.7110, and 1.8229 eV at the valence band state A, B, and C, respectively. The band gap energy of the p-$CdIn_2Te_4$ at room temperature was determined to be 1.2023 eV.

  • PDF

Plasma discharge characteristics of MgO protection layer deposited by using targets made of single crystals, and nano powders

  • Yang, Choong-Jin;Park, Eun-Byeong;Lee, Ho-Sang;Park, Jung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.157-160
    • /
    • 2008
  • Improved properties of second electron emission was evaluated by assemble of 4 inch PDP panel. MgO protection layers were deposited and examined by using both pellets made of extremely pure MgO single crystals and sintered pellets using MgO nano powders. $\gamma$ coefficients higher than 0.11 were obtained from the panel by adopting dopant-controlled MgO single crystals. Especially the MgO layer deposited by sintered pellets made of nano powders showed the higher $\gamma$ coefficients at the operating voltage above 200 volts.

  • PDF

Investigation of γ/γ' Growth by Macro Segregation in the Ni-Base Single Crystal Superalloy, CMSX-10 (CMSX-10 단결정 초내열합금에서 거시편석에 따른 γ/γ' 응고조직 형성)

  • Yoon, Hyeyoung;Sung, Changhoon;Shin, Jongho;Han, Seong Zeon;Lee, Jehyun
    • Korean Journal of Materials Research
    • /
    • v.25 no.9
    • /
    • pp.435-441
    • /
    • 2015
  • The ${\gamma}/{\gamma}^{\prime}$ two-phases, commonly known as a eutectic structure, are observed in the ${\gamma}$ interdendritic region of a Ni-base superalloy. However, the growth behavior of the ${\gamma}/{\gamma}^{\prime}$ two-phases, whether it is of eutectic or peritectic nature, has not been decidedly established. Directional solidifications were, thus, performed with the planar interface at a low growth rate of $0.5{\mu}m/s$ in order to promote macro segregation. Directional solidification started with the ${\gamma}$ planar interface and the ${\gamma}^{\prime}$ phase nucleated on the ${\gamma}$ planar interface at the solidification fraction of 0.75. The ${\gamma}/{\gamma}^{\prime}$ two-phases showed the ${\gamma}^{\prime}$ rod structure as major phase and the ${\gamma}$ minor phase between ${\gamma}^{\prime}$ rods, and the volume fraction of the ${\gamma}$ phase changed continuously with an increasing solidification fraction. The two-phase ${\gamma}/{\gamma}^{\prime}$ is seen as the coupled peritectic.

Microscopic Studies of the Magnetic and Thermal Properties in Ba-ferrite Single Crystal (Ba-Ferrite 단결정의 자기적 및 열적 현상에 관한 미시적 연구)

  • Sur, J.C.;Choi, J.W.
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.4
    • /
    • pp.152-155
    • /
    • 2009
  • Ba-Ferrite single crystals were prepared and the magnetic and thermal properties were characterized by Mossbauer spectroscopy. The single crystal layer was cut in the c-axis and radiated to the surface by ${\gamma}$-rays for Mossbauer spectroscopy. We found out that the spin states in Fe ions were parallel to the ${\gamma}$-rays direction and the whole crystal bulk formed only one crystal with the same spin direction. $M\"{o}ssbauer$ spectra in single crystal have only 4 sets of 4 absorption lines in each Fe site when the ${\gamma}$-rays have the same radiation direction with the c-axis in the crystal, and there was no 2b-site spectrum. The zero absorption of 2b-site means that there was a fast diffusion motion in a double-well atomic potential at room temperature, in which bipyramidal Fe ions have the two minima at each side mirror plane.

Quantitative Analysis of DNA Single-strand Breaks in EL 4 cells and Mouse Spleen Lymphocytes after Irradiation (방사선에 의한 EL 4 백서 백혈병 세포 및 정상 백서 비장 임파구 DNA Single-Strand Breaks의 정량적 분석과 측정)

  • Yoo Seong Yul;Cho Chul Koo;Koh Kyung Hwan;Park Woo Yoon;Park Young Hwan;Kim Sung Ho;Kim Tae Hwan;Chung In Yong
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.137-144
    • /
    • 1990
  • The filter elution technique was used to assay Co-60 $\gamma$ ray-induced DNA single-strand breaks(SSB) in EL 4 mouse leukemia cell and mouse spleen lymphocyte. The lymphocytes were stimulated with lipopolysaccharide (LPS, 20 $\mug/ml$) to label [${^3}H$] thymidine. EL 4 cells and lymphocytes in suspension were exposed at $0^{\circ}C$ to 0 Gy, 1 Gy, 5 Gy,10 Gy of Co-60 radiation and elution procedure was performed at PH 12.1. The number of DNA single-strand breaks increased with increasing doses of $\gamma$ rays. The strand scission factor (SSF) was estimated in each experiment (eluted volume 21 ml). The slope for EL 4 cells was $0.01301\pm0.00096\;Gy^{-1}(n=5)$ and the slope for lymphocytes was $0.01097\pm0.00091\;Gy^{-1}(n=5)$. The slopes were significantly different (P<0.005). Thus EL 4 cells were more sensitive to induction of DNA SSB by ionizing radiation than lymphocytes.

  • PDF

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.