• Title/Summary/Keyword: Single crossing

Search Result 158, Processing Time 0.029 seconds

Alexander Polynomials of Knots Which Are Transformed into the Trefoil Knot by a Single Crossing Change

  • Nakanishi, Yasutaka
    • Kyungpook Mathematical Journal
    • /
    • v.52 no.2
    • /
    • pp.201-208
    • /
    • 2012
  • By the works of Kondo and Sakai, it is known that Alexander polynomials of knots which are transformed into the trivial knot by a single crossing change are characterized. In this note, we will characterize Alexander polynomials of knots which are transformed into the trefoil knot (and into the figure-eight knot) by a single crossing change.

Single-row Routing Algorithm with Between Node Congestion (간노드과잉을 고려한 단층 열 라우팅 알고리즘)

  • 이남일;이상조
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.603-609
    • /
    • 1987
  • In this paper, the single-row routing algorithm for munimizing the street congestion and reducing the between node congestion is deviced. To reduce the between node congestion, reference line crossing is defined and used. Reducing the number of total reference line crossing means reducing the total length which help reduce the power consumption of the integrated system and reducing the between node congestin which help reduce the wiring area. This algorithm has been implemented and tested with various example, then produced good results.

  • PDF

Selection of Superior Strains of Cordyceps militaris with Enhanced Fruiting Body Productivity

  • Sung, Jae-Mo;Park, Young-Jin;Lee, Je-O;Han, Sang-Kuk;Lee, Won-Ho;Choi, Sung-Keun;Shrestha, Bhushan
    • Mycobiology
    • /
    • v.34 no.3
    • /
    • pp.131-137
    • /
    • 2006
  • In vitro fruiting bodies were produced from ten different isolates of Condyceps militaris EFCC C-5736, EFCC C-5941, EFCC C-5976, EFCC C-6040, EFCC C-6849, EFCC C-7268, EFCC C-7342, EFCC C-7992, EFCC C-8027 and EFCC C-8549. Single ascospores were isolated from in vitro grown fruiting bodies and used for fruiting body production in brown rice medium by both intra-strain crossing and out-crossing. Length and dry wt. of stromata grown in vitro were measured. Strains producing highest dry wt. of stromata were selected. Both intra-strain crossings and inter-strain crossings of single ascospore strains were found to produce profuse fruiting bodies of C. militaris.

A Novel Predictive Digital Controlled Sensorless PFC Converter under the Boundary Conduction Mode

  • Wang, Jizhe;Maruta, Hidenori;Matsunaga, Motoshi;Kurokawa, Fujio
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • This paper presents a novel predictive digital control method for boundary conduction mode PFC converters without the need for detecting the inductor current. In the proposed method, the inductor current is predicted by analytical equations instead of being detected by a sensing-resistor. The predicted zero-crossing point of the inductor current is determined by the values of the input voltage, output voltage and predicted inductor current. Importantly, the prediction of zero-crossing point is achieved in just a single switching cycle. Therefore, the errors in predictive calculation caused by parameter variations can be compensated. The prediction of the zero-crossing point with the proposed method has been shown to have good accuracy. The proposed method also shows high stability towards variations in both the inductance and output power. Experimental results demonstrate the effectiveness of the proposed predictive digital control method for PFC converters.

The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System (단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.

Dead Angle Reduction of Single-Stage PFC Using Controllable Coupled Inductors

  • Tavassol, Mohammad Mehdi;Farzanehfard, Hosein;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.78-85
    • /
    • 2015
  • This paper presents a new structure of single-stage flyback power factor correction (PFC) converter with a controllable coupled negative magnetic feedback (NMF) winding. NMF winding is used to reduce the bulk capacitor voltage at high line voltages and light loads. However, it would cause line current distortion at zero crossing condition. In the proposed circuit, a series winding is used with NMF inductor to eliminate the NMF inductor at low line voltages. As a result, the dead angle of the input current, near zero voltage crossing, is eliminated and the power factor is increased. The presented experimental results of the proposed PFC converter confirm the integrity of the new idea and the theoretical analysis.

A New On-Line Dead-Time Compensator for Single-Phase PV Inverter (단상 PV 인버터용 온라인 데드타임 보상기 연구)

  • Vu, Trung-Kien;Lee, Sang-Hoey;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.409-415
    • /
    • 2012
  • This paper presents a new software-based on-line dead-time compensation technique for a single-phase grid-connected photovoltaic (PV) inverter system. To prevent a short circuit in the inverter arms, a switching delay time must be inserted in the pulse width modulation (PWM) signals. This causes the dead-time effect, which degrades the system performance around zero-crossing point of the output current. To reduce the dead-time effect around the zero-crossing point of grid current, a harmonic mitigation of grid current is used as an additional part of the synchronous frame current control scheme. This additional task mitigates the harmonic components caused by the dead-time from the grid current. Simulation and experimental results are shown to verify the effectiveness of the proposed dead-time compensation method in the single-phase grid-connected inverter system.

Performance Improvement on Cycloconverter-fed Induction Motor Speed Control System (공침법을 이용한 PbTiO3-Polymer O-3 압전 Composites)

  • Cho, Ok-Kyun;Shin, Hwi-Beom;Yuon, Myung-Joong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.352-359
    • /
    • 1987
  • The cycloconverter operating on a circulating current-free mode has many zero crossing points. If an exact zero crossing points are not detected, the three phase-unbalanced currents will flow in a motor. In this paper, the current feedback using a current reference wave is proposed to improve the problems of zero crossing detection, three phase-unbalanced voltages, currents, and torgue ripples. To prevent the saturation of the air gap flux and keep the torque constant, the constant voltage / hertz control with IR compensation is adopted. The PI-controller is designed using the linearized model of the cycloconverterinduction motor system. Alsi, Z-80A single board computer has been used to implement the proposed scheme which results in the performance improvement of cycloconterter-fed induction motor speed control system.

  • PDF

Bridgeless Buck PFC Rectifier with Improved Power Factor

  • Malekanehrad, Mahdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.323-331
    • /
    • 2018
  • Buck power factor correction (PFC) converters, compared with conventional boost PFC converters, exhibit high efficiency performance in the entire range of universal line voltage. This feature has gotten more attention for eliminating the zero crossing dead angle of buck PFC rectifiers. Furthermore, bridgeless structures for the reduction of conduction losses have been proposed. The aim of this paper is to introduce a single-phase buck rectifier that simultaneously has unity power factor (PF) and bridgeless structure while operating in the continuous conduction mode (CCM). For this purpose, two auxiliary flyback converters without any active switches are applied to a bridgeless buck rectifier to eliminate the zero crossing dead angle and achieve unity power factor, low total harmonic distortion (THD) and high efficiency. The operation and design considerations of the proposed rectifier are verified on a 150W, 48V prototype using a conventional peak-current-mode control. The measurement results show that the proposed rectifier has nearly unity power factor, THD less than 7% and high efficiency.

Local Moves and Gordian Complexes, II

  • Nakanishi, Yasutaka
    • Kyungpook Mathematical Journal
    • /
    • v.47 no.3
    • /
    • pp.329-334
    • /
    • 2007
  • By the works of Levine [2] and Rolfsen [5], [6], it is known that a local move called a crossing-change is strongly related to the Alexander invariant. In this note, we will consider to what degree the relationship is strong. Let K be a knot, and $K^{\times}$ the set of knots obtained from a knot K by a single crossing-change. Let MK be the Alexander invariant of a knot K, and MK the set of the Alexander invariants $\{MK\}_{K{\in}\mathcal{K}}$ for a set of knots $\mathcal{K}$. Our main result is the following: If both $K_1$ and $K_2$ are knots with unknotting number one, then $MK_1=MK_2$ implies $MK_1^{\times}=MK_2^{\times}$. On the other hand, there exists a pair of knots $K_1$ and $K_2$ such that $MK_1=MK_2$ and $MK_1^{\times}{\neq}MK_2^{\times}$. In other words, the Gordian complex is not homogeneous with respect to Alexander invariants.

  • PDF