• 제목/요약/키워드: Single buffer

검색결과 425건 처리시간 0.024초

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

당뇨쥐에서 감태의 혈당, 혈청지질 개선효과 및 신장의 항산화효과 (Effect of Ecklonia cava on the Blood Glucose, Lipids and Renal Oxidative Stress in Diabetic Rats)

  • 김은;김민숙;김세연;김현아
    • 한국식생활문화학회지
    • /
    • 제23권6호
    • /
    • pp.812-819
    • /
    • 2008
  • In this study, we assessed the effects of dietary supplementation with Ecklonia cava on blood glucose, lipid metabolism, and renal oxidative stress in streptozotocin (STZ)-induced diabetic rats. Male Sprague-Dawley rats were divided into a normal rat group fed on a control diet and diabetic rats fed on a control diet or supplemented with powder (15% w/w) or water extract of Ecklonia cava (2.5% w/w). Diabetes was induced by a single injection of STZ (60 mg/kg, ip) in citrate buffer. The animals were fed ad libitum with the experimental diet and water for 5 weeks. Dietary supplementation of Ecklonia cava powder and water extract was shown to reduce blood glucose levels in the diabetic rats, and the water extract was more effective than the powder. Dietary supplementation with Ecklonia cava also reduced LDL cholesterol and increased HDL-cholesterol levels in the diabetic rats. Renal glutathione S-transferase activity was increased in the diabetic rats as compared to the normal rats, but reverted to near control values as the result of dietary supplementation with Ecklonia cava. These results show that Eklonia cava exerts an anti-diabetic effect by improving blood glucose concentrations, LDL/HDL-cholesterol ratios, and antioxidative effects on the kidney in diabetic rats.

$\gamma$線에 照射된 마우스의 血淸蛋白質에 미치는 Cortisone의 影響 (Effect of Cortisone on Serum Protein of Gamma-Irradiated Mice)

  • 조유정;최국헌;남상열
    • 한국동물학회지
    • /
    • 제14권3호
    • /
    • pp.119-124
    • /
    • 1971
  • 1. $^{60}Co$$\gamma$선 128 rad로 마우스를 전신조사시킨 바 대조군과 cortisone투여군에서 총 혈청단백량은 1일구에서 A/G비는 5일구에서 각각 증가의 정점을 나타냈고 이후 정상치로 되돌아가는 경향을 나타냈다. 2. cortisone acetate는 전신조사후 총혈청단백량에 있어서 5, 10 및 20일구에서 증가의 지체성을 나타냈다. 3. cortisone acetate를 전신조사후 A/G비에 있어서 1, 5 및 10일구에서 증가의 지체성을 나타냈다. 4. 이상의 결과로 미루어 보아 전신조사전 cortisone 처리는 혈청단백질의 방사선 감수성을 감소시킴을 알수 있으므로 방사선 방어효과가 있다고 사료된다.

  • PDF

수직방향으로 적층된 InAs 양자점의 광학적 특성

  • 김광무;노정현;박영민;박용주;나종범;김은규;방정호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.93-93
    • /
    • 1999
  • 양자점(Quantum dot : QD)를 이용한 소자를 만들기 위해서는 수직방향으로의 적층이 필수적이다. 양자점의 적층은 수직적으로 같은 위치에 정렬하므로, 고려되어야 할 요소로는 양자점간의 파동함수의 중첩(coupling)에 의한 특성변화, 적층의 진행에 따른 변형(strain)의 증가로 기인되는 volcano 모양으로 나타나는 결함등이 있다. 이러한 결함은 nonradiative recombination center로 작용하여 오히려 효율이 떨어지게 되는 현상이 발생하게 되므로 본 연구에서는 적층횟수에 따른 발광효율의 변화를 조사하여 소자응용에 적절한 적층 조건을 조사하였다. 시료성장은 molecular beam epitaxy (MBE) 장치를 이용하여 GAs(100) 기판위에 GaAs buffer를 58$0^{\circ}C$에서 150nm 성장후 InAs/GaAs 양자점과 50$0^{\circ}C$에서 적층회수 1, 3, 6, 10, 15, 20회로 하였으며 적층성장 이후 GaAs cap layer를 성장하였다. GaAs spacing과 cap layer의 성장온도 역시 50$0^{\circ}C$이며 시료의 분석은 photoluminescence (PL)과 scanning transmission electron microscope (STEM)으로 하였다. 적층횟수를 바꾸어 시료를 성장하기 전에 적층횟수를 10회로 고정하고 spacing 두께를 2.8nm, 5.6nm, 11.2nm로 바꾸어 성장하여 PL 특성을 관찰하여본 결과 spacing이 2.8nm인 경우 수직적으로 정렬된 양자점 간에 coupling이 매우 커서 single layer QD의 PL peak에 비해 약 100nm 정도 파장이 증가하였고, spacing의 두께가 11.2nm 일 경우는 single layer QD와 거의 같은 파장의 빛을 방출하여 중첩이 거의 일어나지 않지만 두꺼운 spacing때문에 PL세기가 감소하였다. 한편, 적층회수에 따른 광학적 특성을 PL로 조사하여 본 결과 peak 파장은 적층횟수가 1회에서 3회로 증가했을 때는 blue shift 하다가 이후 적층이 증가함에 따라 red shift 하였다. 그리고 10층 이상의 적층에서는 excited state에서 기인된 peak이 검출되었다. 이렇나 원인은 적층수가 증가함에 따라 carrier life time이 증가하여 exciter state에 carrier가 존재할 확률이 증가하기 때문으로 생각된다. 또한 PL 세기가 다소 증가하다가 10층 이상의 경우는 다시 감소함을 알 수 있었다. 반치폭도 3층과 6층에서 가장 적은 값을 보였다. 이와 같은 결과는 결함생성과 관련하여 STEM 분석으로 해석되어질 수 있는데 6층 적층시는 양자점이 수직적으로 정렬되어 잘 형성됨을 관찰할 수 있었고 적층에 따른 크기 변화도 거의 나타나지 않았다. 그러나 10층 15층 적층시 몇가지 결함이 형성됨을 볼수 있었고 양자점의 정렬도 완전하게 이루어지지 않음을 볼 수 있었다. 그러므로 수직적층된 InAs 양자점의 광학적 특성은 성장조건에 따른 결함생성과 밀접한 관련이 있으며 상세한 논의가 이루어질 것이다.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

주문형 비디오 서비스 시스템에서 VCR 기능을 위한 Batching 전송 (Batching delivery for VCR-like functions in video-on-demand service system)

  • 박호균;유황빈
    • 한국통신학회논문지
    • /
    • 제22권12호
    • /
    • pp.2852-2859
    • /
    • 1997
  • 주문형 비디오(Video-On-Demand) 시스템은 광대역 통신 네트워크를 통하여 사용자가 원하는 영화를 융통성있게 제공하는 전자 비디오 대여 시스템이다. 대부분의 제안된 VOD 시스템은 사용자와 비디오 서버 간에 일대일 연결로 설계되어 있어 하나의 비디오 서버 스트림을 전용 전송 채널로 각 사용자에게 개별적으로 서비스되었다. 그러나 동일한 비디오 스트림을 엑세스하는 다수의 사용자에게 개별적으로 전용 전송 채널로 서비스를 하는 것은 매우 비효율적이며 비용의 낭비를 초래한다. 따라서, 비용 효율성을 얻기 위하여, 동일한 비디오 스트림을 요구하는 다수의 사용자에게 멀티캐스트 기능을 이용하여 하나의 스트림으로 전송하는 batching 기법이 연구되었다. 그러나, batching에 의한 멀티캐스트의 사용은 오히려 VCR 기능의 특성과 on-demand 특성을 저하시키는 단점을 가지고 있다. 본 논문에서는 서버에 대한 I/O와 네트워크 대역폭을 감소시키기 위하여 가입자 인접 부근인 엑세스 노드에 가변 playout point를 갖는 동적 버퍼를 두어 동일한 비디오 스트림을 요구하는 사용자들을 batching으로 전송하는 기법을 제안하였다. 따라서, 사용자당 비디오 전송 비용을 감소시켰으며, 사용자들이 true VOD를 사용하는 것과 마찬가지로 대화형 VCR 명령을 가능하게 하였다. 또한, 초기 요구나 VCR 기능이 수행된 후에도 어떠한 batching지연이 없이 바로 멀티캐스트 비디오 스트림을 전송할 수 있었으며, 소수의 서버 용량으로 많은 사용자들에게 서비스하여 시스템의 성능을 향상시킬 수 있었다.

  • PDF

동양배(신고(新高)) Protease의 정제(精製) 및 성질(性質)에 관(關)하여 (Purification and Characterization of Oriental Pear(Niitaka, Pyrus pyrifolia Nak.) Protease)

  • 김성열;정해정;김승겸;신철승
    • 농업과학연구
    • /
    • 제16권2호
    • /
    • pp.225-238
    • /
    • 1989
  • 동양배(신고(新高))에서 protease를 추출(抽出), 정제(精製)하여 그의 특성(特性)을 검토(檢討)한 결과(結果)는 다음과 같다. 1. 배의 protease는 배의 과육(果肉)-정량(定量)과 5mM의 cysteine, 40mM 2-mercaptoethanol 및 2mM의 EDTA를 함유(含有)하는 0.1M-sodium phosphate buffer(pH6.5)0.7배량(倍量)(v/w)을 homogenizer에 넣고 10,000rpm으로 5분간(分間) 추출(抽出)하는 것이 효과적(效果的)이었다. 2. 상기(上記) 방법(方法)에 의(依)해서 파쇄(破碎)한 것을 cheese cloth로 여과(濾過)하여 10,000g로 20분간(分間) 원심분리(遠心分離)하여 얻어지는 상징액(上澄液) 조효소액(粗酵素液)으로 하여 유안(硫安) 분획(分劃), Sephadex G-100 filtration 및 DEAE-Sephadex A-50 column chromatography를 거쳐 전기영동상(電氣泳動上)으로 단일(單一)한 효소단백질(酵素蛋白質)을 얻었다. 3. 정제효소(精製酵素)의 비활성(比活性)은 10.78배(倍) 증가(增加)하였고, 활성수율(活性收率)은 722%에 달(達)하였다. 4. 정제효소(精製酵素)의 분자량(分子量)은 SDS전기영동법(電氣泳動法)에 의(依)하여 측정(測定)하였을 때 51,000이었으며, Km값은 $54.5mg/m{\ell}$이었다. 5. 본(本) 효소(酵素)의 작용(作用) 최적(最適) pH는 6.0이었고, pH5.5~6.5에서 안정(安定)하였으며, 작용(作用) 최적(最適) 온도는 $50^{\circ}C$이고, $50^{\circ}C$ 이하(以下)에서 안정(安定)하였다. 6. 본(本) 효소(酵素)는 casein을 가장 잘 분해(分解)하였고 hemoglobin 분해력(分解力)은 casein분해력(分解力)의 55%에 달(達)하였으며, elastin분해력(分解力)은 극(極)히 미약(微弱)하였다. 7. 본(本) 효소(酵素)는 p-chloromercuribenzoic acid에 의(依)해서는 강(强)한 저해(沮害)를 받았고, $HgCl_2$, $MnSO_4$에 의(依)해서도 저해(沮害)를 받았으나 cysteine등(等)의 각종(各種) 환원제(還元劑), EDTA, phenylmethylsulfonyl fluoride 및 N-tosyl-L-phenylalanine chloromethyl ketone에 의(依)해서는 저해(沮害)를 받지 않았다.

  • PDF

유치 수복물에 따른 주변 법랑질의 탈회 저항성: QLF를 이용한 연구 (RESISTANCE TO DEMINERALIZATION OF ENAMEL OF PRIMARY TEETH ACCORDING TO RESTORATIONS: IN VITRO STUDY USING QLF)

  • 권해숙;현홍근;김영재;김정욱;장기택;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제37권1호
    • /
    • pp.44-52
    • /
    • 2010
  • 본 연구에서는 유치 수복물의 불소 방출 여부에 따른 주변 법랑질의 탈회 저항성과 재광화 효과를 살펴보고자 하였다. 건전 유전치 48개를 16개씩 임의로 세 군으로 나누어, $Filtek^{TM}$ Z250(1군), F2000(2군), $Ketac^{TM}$ N100(3군)을 사용하여 제조사의 지시에 따라 충전하였다. 3일 동안 인공 우식 병소를 유발한 후, 14일 동안 인공 타액에 담가 재광화를 유발하였다. Quantitative light-induced fluorescence(QLF)를 이용하여 실험 단계와 시간에 따른 무기질 소실량(${\Delta}Q$)의 변화를 관찰한 결과는 다음과 같다. 1. 탈회가 일어난 인공 우식 병소의 ${\Delta}Q$ 값은 3군, 2군, 1군 순으로 작게 나타났고, 이 중 3군은 1군에 비해 유의한 탈회 저항성을 보였다. 2. 1군, 2군, 3군 모두 재광화 1일 후부터 초기 인공 우식 병소의 ${\Delta}Q$ 값과 비교 시 유의한 차를 보였으며, 관찰 기간 동안 지속적인 증가 양상을 나타내었다. 3. 재광화 속도를 의미하는 ${\Delta}$(${\Delta}Q$)/일 값은 각 군에서 처음 1일 동안 유의성 있게 크게 나타났으며, 그 이후 급속히 감소하였다. 4. 수복 재료에 따른 재광화 정도는 각 군 간에 유의한 차이가 없었다.

A New Device for Intrauterine Artificial Insemination in the Dog

  • Kong, I.K.;Yu, D.J.;Jeong, S.R.;Oh, I.S.;Yang, C.J.;Cho, S.G.;Bae, I.H.;Oh, D.H.;Kim, H.R.;Cho, S.K.;Park, C.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권2호
    • /
    • pp.180-184
    • /
    • 2003
  • The intrauterine inseminator (IUI) was developed to provide the method of depositing dog semen into the uterine body instead of the vagina. The IUI consists of a vaginal endoscope, a balloon sheath, and injection catheter. When the endoscope is inserted into the vagina and the balloon expanded with air, the cervical os becomes visible so a injection catheter can be inserted through the cervix for deposition of the frozen-thawed semen. The efficacy of the IUI device was compared to intra-vaginal artificial insemination using semen that had been collected and frozen from pooled sperm-rich fraction of ejaculates collected from two Jindo dog donors. Aliquots of semen were extended with a Tris-egg yolk diluent, centrifuged, the seminal plasma removed, the pellet resuspended with the same diluent, and cooled to $5^{\circ}C$ over a 2 h period. A Tris-egg yolk-glycerol extender was added at $5^{\circ}C$; after 1 h, semen was loaded into 0.5 ml straws, and straws were frozen in LN vapor for 5 min, and immersed in LN for storage. The final sperm concentration for freezing was approximately $100{\times}10^{6}cells/ml$. The straws were thawed at $70^{\circ}C$ for precisely 6 sec, 1.5 ml Tris-egg yolk buffer at $38^{\circ}C$ added, and the 2 ml of thawed semen was used for a single insemination using the IUI device. Each bitch was inseminated at optimal insemination point, which was estimated by vaginal epithelial cells staining and progesterone concentration analysis. Use of the IUI device resulted in 21 of 26 females giving birth to 89 pups ($4.2{\pm}1.6$ pups per litter), while intra-vaginal AI resulted in 6 of 15 females whelping a total of 17 pups ($2.8{\pm}1.2$ pups per litter). We believe the IUI device is easier to use than previously described devices used for intrauterine insemination. In our experience the expansion of the balloon has a calming effect on the bitch that aids the inseminator. These results indicate that the IUI device was able to provide high fertility with 50 million frozen sperm per insemination and two inseminations.

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.