• Title/Summary/Keyword: Simultaneous measurement

Search Result 482, Processing Time 0.032 seconds

Derivation of the Ambient Nitrogen Dioxide Mixing Ratio over a Traffic Road Site Based on Simultaneous Measurements Using a Ground-based UV Scanning Spectrograph

  • Lee, Han-Lim;Noh, Young-Min;Ryu, Jae-Yong;Hwang, Jung-Bae;Won, Yong-Gwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • Simultaneous measurements using a scanning spectrograph system and transmissometer were performed for the first time over an urban site in Gwangju, Korea, to derive the ambient $NO_2$ volume mixing ratio. The differential slant column densities retrieved from the scanning spectrograph system were converted to volume mixing ratios using the light traveling distance along the scanning line of sight derived from the transmissometer light extinction coefficients. To assess the performance of this system, we compared the derived $NO_2$ volume mixing ratios with those measured by an in situ chemiluminescence monitor under various atmospheric conditions. For a cloudless atmosphere, the linear correlation coefficient (R) between the two data sets (i.e., data derived from the scanning spectrograph and from the in situ monitor) was 0.81; the value for a cloudy atmosphere was 0.69. The two sets of $NO_2$ volume mixing ratios were also compared for various wind speeds. We also consider the measurement errors, as estimated from an error propagation analysis.

Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans (갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구)

  • Jung-Soo Kim;Geun-Woo Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

GraphSLAM Improved by Removing Measurement Outliers (측정 아웃라이어 제거를 통해 개선된 GraphSLAM)

  • Kim, Ryun-Seok;Choi, Hyuk-Doo;Kim, Eun-Tai
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.493-498
    • /
    • 2011
  • This paper presents the GraphSLAM improved by selecting the measurement with respect to their likelihoods. GraphSLAM estimates the robot's path and map by utilizing the entire history of input data. However, GraphSLAM's performance suffers a lot from severely noisy measurements. In this paper, we present GraphSLAM improved by the selective measurement method. Thus the presented GraphSLAM provides higher performance compared with the standard GraphSLAM.

Three-Dimensional Fluid Flow Analysis of Photoacoustic Spectroscopy Cell for Measurement of Automotive Exhaust Gas (자동차 배출가스 측정을 위한 Photoacoustic Spectroscopy Cell의 3차원 유동장 해석)

  • 김현철;박종호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.111-118
    • /
    • 2003
  • Recently, environmental damage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle. Especially, exhaust emission from diesel vehicles are blown to be harmful to human health and environment. Photoacoustic Spectroscopy system is very useful technology for simultaneous and continuous measurement of the various components of the automotive exhaust gas. In this study, in order to reduce emission gases from automobile, we tried to develop the measurement system of Photoacoustic Spectroscopy. To improve performance of high sensitive Photoacoustic Spectroscopy system for automotive exhaust emissions, the shape of Photoacoustic Spectroscopy cell was optimized to use the flow analysis. And Exhaust emission data of the 1,500cc gasoline engine was fixed the working fluid. The characteristics of fluid flow for cell were analyzed by various conditions in detail.

Four Degree-of-Freedom Geometric Error Measurement System with Common-Path Compensation for Laser Beam Drift

  • Qibo, Feng;Bin, Zhang;Cuifang, Kuang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • A precision four-degree-of-freedom measurement system has been developed for simultaneous measurement of four motion errors of a linear stage, which include straightness and angular errors, The system employs a retro-reflector to detect the straightness errors and a plane mirror to detect the angular errors. A common-path compensation method for laser beam drift is put forward, and the experimental results show that the influences of beam drift on four motion errors can be reduced simultaneously. In comparison with the API 5D laser measuring system, the accuracy for straightness measurement is about ${\pm}1.5{\mu}m$ within the measuring range of ${\pm}650{\mu}m$, and the accuracy for pitch and yaw measurements is about ${\pm}1.5$ arc-seconds within the range of ${\pm}600$ arc-seconds.

Development of Three Dimensional Scanner for Anthropometric Measurement (인체측정용 3차원 스캐너 제작)

  • Kim, Min-Hyo;Nam, Yun-Ja
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

Design and Implementation of a DSP-Based Multi-Channel Power Measurement System

  • Jeon Jeong-Chay;Oh Hun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.214-220
    • /
    • 2005
  • In order to improve energy efficiency and solve power disturbances, power components measurement for both the supply and demand side of a power system must be implemented before appropriate action on the power problems can be taken. This paper presents a DSP (Digital Signal Processor)-based multi-channel (voltage 8-channel and current 10-channel) power measurement system that can simultaneously measure and analyze power components for both supply and demand. Voltage 8-channel and current 10-channel measurement is made through voltage and current sensors connected to the developed system, and power components such as reactive power, power factor and harmonics are calculated and measured by the DSP. The measured data are stored in a personal computer (PC) and a commercial program is then used for measurement data analysis and display. After voltage and current measurement accuracy revision using YOKOGAWA 2558, the developed system was tested using a programmable ac power source. The test results showed the accuracy of the developed system to be about 0.3 percent. Also, a simultaneous measurement field test of the developed system was implemented by application to the supply and demand side of the three-phase power system.

Partial EBG Structure with DeCap for Ultra-wideband Suppression of Simultaneous Switching Noise in a High-Speed System

  • Kwon, Jong-Hwa;Kwak, Sang-Il;Sim, Dong-Uk;Yook, Jong-Gwan
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.265-272
    • /
    • 2010
  • To supply a power distribution network with stable power in a high-speed mixed mode system, simultaneous switching noise caused at the multilayer PCB and package structures needs to be sufficiently suppressed. The uni-planar compact electromagnetic bandgap (UC-EBG) structure is well known as a promising solution to suppress the power noise and isolate noise-sensitive analog/RF circuits from a noisy digital circuit. However, a typical UC-EBG structure has several severe problems, such as a limitation in the stop band's lower cutoff frequency and signal quality degradation. To make up for the defects of a conventional EBG structure, a partially located EBG structure with decoupling capacitors is proposed in this paper as a means of both suppressing the power noise propagation and minimizing the effects of the perforated reference plane on the signal quality. The proposed structure is validated and investigated through simulation and measurement in both frequency and time domains.

Simultaneous identification of damage in bridge under moving mass by Adjoint variable method

  • Mirzaee, Akbar;Abbasnia, Reza;Shayanfar, Mohsenali
    • Smart Structures and Systems
    • /
    • v.21 no.4
    • /
    • pp.449-467
    • /
    • 2018
  • In this paper, a theoretical and numerical study on bridge simultaneous damage detection procedure for identifying both the system parameters and input excitation mass, are presented. This method is called 'Adjoint Variable Method' which is an iterative gradient-based model updating method based on the dynamic response sensitivity. The main advantage of proposed method is inclusion of an analytical method to augment the accuracy and speed of the solution. Moving mass is a model which takes into account the inertia effects of the vehicle. This interaction model is a time varying system and proposed method is capable of detecting damage in this variable system. Robustness of proposed method is illustrated by correctly detection of the location and extension of predetermined single, multiple and random damages in all ranges of speed and mass ratio of moving vehicle. A comparison study of common sensitivity and proposed method confirms its efficiency and performance improvement in sensitivity-based damage detection methods. Various sources of errors including the effects of measurement noise and initial assumption error in stability of method are also discussed.

Simultaneous Evaluation of Cellular Vitality and Drug Penetration in Multicellular Layers of Human Cancer Cells

  • Al-Abd Ahmed Mohammed;Lee Joo-Ho;Kuh Hyo-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.309-314
    • /
    • 2006
  • The multicellular layers(MCL) of human cancer cells is a three dimensional(3D) in vitro model for human solid tumors which has been used primarily for the assessment of avascular penetration of anti-cancer drugs. For anti-cancer drugs with penetration problem, MCL represents a good experimental model that can provide clinically relevant data. Calcein-AM is a fluorescent dye that demonstrates the cellular vitality in a graded manner in cancer cell culture system. In the present study, we evaluated the use of calcein-AM for determination of anti-proliferative activity of anti-cancer agents in MCL model of DLD-1 human colorectal cancer cells. Optical sectioning of confocal imaging was compromised with photonic attenuation and penetration barrier in the deep layers of MCL. By contrast, fluorescent measurement on the cryo-sections provided a feasible alternative. Cold pre-incubation did not enhance the calcein-AM distribution to a significant degree in MCL of DLD-1 cells. However, the simultaneous determination of drug penetration and cellular vitality appeared to be possible in drug treated MCL. In conclusion, these data suggest that calcein-AM can be used for the simultaneous determination of drug-induced anti-proliferative effect and drug penetration in MCL model.