• 제목/요약/키워드: Signal failure

검색결과 448건 처리시간 0.023초

超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診 (Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number)

  • 권동진;곽희로;정상진;김정부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

2차원 절삭시의 각종 파라메터와 음향 방출 신호와의 상호 관계에 관한 연구 (A Study on the Correlation of Orthogonal Cutting all sorts Parameter and Acoustic Emission Signal)

  • 김재열;심재기;박환규;오환교
    • 한국정밀공학회지
    • /
    • 제8권1호
    • /
    • pp.74-83
    • /
    • 1991
  • A study on the Correlation of Orthogonal Cutting Parameter (Cutting speed, Depth of cut, Feed Rate) and Acoustic Emission Signal. It is well known that acoustic emission (AE) is the emission of elastic wave resulting from the deformation and fracture of materials. This study estabished correlation of orthogonal cutting parameter and AE signal, and researched into in-process monitoring of tool wear and failure. The results are as follow; 1. AE RMS was under the influence of cutting speed but hardly influenced by depth of cut and feed rate. 2. AE RMS was under the influence of flank wear. 3. AE count rate increased by increased cutting speed. 4. AE RMS value was rapidly increased in 130 m flank wear.

  • PDF

Cause Analysis and Improvement of Signal Interference in Byteflight Data Bus

  • Kwon, Jung-Hyuk;Tak, Su-Pyeong;Kwon, Ik-Hyun;Lee, Wang-Sang
    • 항공우주시스템공학회지
    • /
    • 제15권6호
    • /
    • pp.50-58
    • /
    • 2021
  • Byteflight is developed based on RS-485 communication (an international standard), and it can be used as a data bus during the operation of an integrated avionics system in the latest aircraft. Therefore, the integrated avionics system can perform an effective and safe flight mission only when the accurate and seamless display of flight information, communication, and accurate functions of navigation are implemented. In this study, cause analysis and failure investigation were performed on screen abnormalities and communication interruptions due to signal interference in the Byteflight data bus of the integrated avionics system during aircraft operation. To improve signal interference between avionics units, the branch point and wiring path of the Byteflight data bus were changed, and the verification result of the improved method was also described.

Elimination of Screen-Flickering Phenomenon in Multi-Function Display During Flight of Fixed-Wing Aircraft

  • Kwon, Jung-Hyuk;Kwon, Ik-Hyun;Beak, Jun-Ho;Jang, Geun-Hyung;Lee, Wang-Sang
    • 항공우주시스템공학회지
    • /
    • 제15권2호
    • /
    • pp.45-51
    • /
    • 2021
  • In this study, we aim to eliminate the flickering phenomenon in multi-function display (MFD) units during the flight of fixed-wing aircraft. To execute flight missions effectively, the video signals transmitted to MFDs must provide information accurately and seamlessly. Therefore, a method for addressing the flickering phenomenon-including cause analysis and failure diagnosis-is adopted; specifically, a wiring configuration with a direct connection between the video signal cables and with a short cable length is adopted. The proposed method is experimentally verified using a flight test.

초음파의 형상인식법을 이용한 저널베어링의 마멸파손 검지 (The Early Detection of Journal Bearing Failures by a Pattern Recognition of Ultrasonic Wave)

  • 윤의성;손동구;안효석
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2061-2068
    • /
    • 1993
  • Condition monitoring technology is of great importance for the maintenance of complex machinery in view of its early monitoring of the abnormal condition and the protection against failure. Several methods have been used for the detection of failure of journal bearings, one of the main elements of mechanical system. The methods most frequently used are vibration and temperature monitoring, but these are unable to monitor the wear conditions exactly. In this study, an ultrasonic measument method, one of the non-destructive testing methods, was introduced as the monitoring technology. Furtermore a pattem recognition method was applied to analyze the ultrasonic signal. The monitoring system using the pattern recognition method is composed of digital signal processing units and uses Hamming net algorithm for the recognition of ultrasonic waves. From the journal bearing wear test, the occurrence of adhesive wear of the white metal in rubbing contact with the shaft was exactly detected by this system, and the wear status of the journal bearing was monitored by measuring the wear thickness.

통신용 증폭기의 ESD 고장분석과 대책 (Failure Analysis and Solution of ESD for Amplifier Used in Telecommunication)

  • 황순미;정용백;김철희;이관훈
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권3호
    • /
    • pp.251-265
    • /
    • 2011
  • Low-noise amplifier(LNA) is a component that amplifies the signal while lowering the noise figure of high-frequency signal. LNA holds a very important position in RF system so that it is widely used for telecommunication. Electro static discharge(ESD) is the most common cause of malfunction for low-powered components, such as Large Scale Integration and IC type LNA is weak in ESD. This thesis studies static effect of communication LNA. It analyzes ESD effect, which occurs within LNA circuit, and describes testing standard and methods. In order to find out LNA's susceptiblity to electro static, two well-recognized communication IC type LNA models were selected to be tested. Then static-induced malfunction was carefully analyzed and it suggests architectural problem and improvement from the LNA's ESD point of view.

Deferred commit 방식에 의한 광통신망의 복구제어 및 지연시간 분석 (Restoration control of optical network and delay time analysis based on deferred commit scheme)

  • 조평동;김상하
    • 한국통신학회논문지
    • /
    • 제28권4B호
    • /
    • pp.306-315
    • /
    • 2003
  • 광통신망에서는 언제 발생할 지 모를 통신경로상의 장애에 대비하여 통신망의 생존성을 확보할 수 있는 장애복구가 중요하다. 본 논문에서는 백업경로 자원을 공유하는 메쉬형태의 광통신망에서 장애시 이를 복구하는 방법에 대해 기존 제안된 방식을 분석하고 이에 대해 자원의 활용성과 관리의 효율성을 높일 수 있는 deferred commit 복구 구조를 제안하였다. 그리고 복구신호의 전달에 필요한 메시지 형태 및 포맷, 전달흐름 등을 구체적으로 제시하였다. 또한 deffered commit 구조에서 소요되는 지연시간을 내용적으로 규명하고 시뮬레이션을 통해 여러 복구 구조들간의 특성을 비교하였다.

직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계 (Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device)

  • 이예지;윤재서;조성철;노성여
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

지적보전시스템의 실시간 다중고장진단 기법 개발 (Development of Multiple Fault Diagnosis Methods for Intelligence Maintenance System)

  • 배용환
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.23-30
    • /
    • 2004
  • Modern production systems are very complex by request of automation, and failure modes that occur in thisautomatic system are very various and complex. The efficient fault diagnosis for these complex systems is essential for productivity loss prevention and cost saving. Traditional fault diagnostic system which perforns sequential fault diagnosis can cause catastrophic failure during diagnosis when fault propagation is very fast. This paper describes the Real-time Intelligent Multiple Fault Diagnosis System (RIMFDS). RIMFDS assesses current machine condition by using sensor signals. This system deals with multiple fault diagnosis, comprising of two main parts. One is a personal computer for remote signal generation and transmission and the other is a host system for multiple fault diagnosis. The signal generator generates various faulty signals and image information and sends them to the host. The host has various modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault diagnosis and graphic representation of the results. RIMFDS diagnoses multiple faults with fast fault propagation and complex physical phenomenon. The new system based on multiprocessing diagnoses by using Hierarchical Artificial Neural Network (HANN).