• 제목/요약/키워드: Signal Equipment

검색결과 958건 처리시간 0.029초

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

도시철도 실시간 모니터링 시스템 적용 사례 (Application of 5678SMRT Real-time Monitoring system)

  • 윤재관;박종헌;김기춘
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.737-747
    • /
    • 2011
  • 5678SMRT has installed various sensor for operating conditions(field of electric, facilities, signal, communication equipment and track) and environment of Every Function Room for remotely detecting and monitoring. Installed sound sensor for analyzed after remotely heard the noise of every equipment at Every Function Room and temperature sensor for check the temperature condition of Every Function Room. Additional installed voltage sensor in signal equipment room for monitoring RF track-circuit's voltage condition. Installed displacement sensor at The Chungdam bridge's railway for measuring and monitoring track displacement caused by temperature change and Pan/Tilt camera at sub-station and drainage for remotely field monitoring. Installed sensor for each equipment's operating condition and failure at Every Function Room then periodic check of workforce turned to around-the-clock surveillance by sensor therefore improvement of operating equipment. SMRT is lots of prevent a failure by Immediately detect of precondition of equipment failure by analyzed the sensor data. If the occurrence of an failure, become detected Immediately so possibility correct diagnosis and order by remotely field check by installed camera and sound sensor at field.

  • PDF

항공 시스템 기반의 통신신호 방향 탐지를 위한 비행 보정 기법 (In-Flight Calibration Method for Direction Finding of Communication Signals based on Aviation Systems)

  • 장재원;주증민
    • 한국전자파학회논문지
    • /
    • 제30권4호
    • /
    • pp.290-299
    • /
    • 2019
  • 신호를 송출하는 신호원의 방향을 추정하기 위하여 다수개의 안테나를 이용하는 방향 탐지 장치는 조난자를 구출하거나 규정된 송신원의 위치를 파악하기 위하여 사용된다. 방향 탐지를 수행할 때에는 방향 탐지 장치와 다수개의 안테나를 탑재한 시스템의 외형과 재질에 따라서 반사파가 존재하고 신호의 왜곡이 발생된다. 따라서 신호원의 방위각을 정확하게 추정하기 위해서는 방향 탐지 장치 개발 간에 안테나 배치와 시스템 외형에 따른 영향성을 반영하기 위한 보정을 수행해야만 한다. 본 논문에서는 항공 시스템을 이용한 통신신호 방향 탐지 장치 개발을 위하여 수행되는 비행 보정기법을 설명하고, 비행 보정을 통하여 얻게 된 위상 보정 데이터를 적용할 경우의 방향 탐지 성능을 분석한다.

Investigation of Relation between EFTB Test and RF Conductive Immunity Test Using BER and Baseband Signal

  • Kuwabara, Nobuo;Irie, Yasuhiro;Hirasawa, Norihito;Akiyama, Yoshiharu
    • Journal of electromagnetic engineering and science
    • /
    • 제11권4호
    • /
    • pp.274-281
    • /
    • 2011
  • High-speed telecommunication systems are influenced by electromagnetic environments because they need a wide bandwidth to transmit signals. Immunity tests of telecommunication equipment are effective for improving its immunity to electromagnetic environments. However, immunity tests are expensive to carry out because there are several different tests. The correlation among the tests should therefore be examined in order to reduce the kinds of tests that are necessary. This paper investigates the correlation between the electrical fast transient/burst (EFTB) test and the radio frequency (RF) conductive immunity test. Imitation equipment was constructed with a balun, and a baseband signal was transmitted from the associated equipment to the imitation equipment. Then, disturbances were applied to the equipment, and the telecommunication quality was evaluated by using the bit error rate (BER). The results from the EFTB test indicated that the BER was less than $6{\times}10^{-5}$ and the value was independent of the peak value. The results from the RF conductive immunity test indicated that the BER was affected by the longitudinal conversion loss (LCL).

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization Applications

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.717-730
    • /
    • 2016
  • The harmonic components of grid voltage result in oscillations of the calculated phase obtained via phase synchronization. This affects the security and stability of grid-connected converters. Moving average filter, delayed signal cancellation and their related harmonic elimination algorithms are major methods for such issues. However, all of the existing methods have their limitations in dealing with multiple harmonics issues. Furthermore, few studies have focused on a comparison and evaluation of these algorithms to achieve optimal algorithm selections in specific applications. In this paper, these algorithms are quantitatively analyzed based on the derived mathematical models. Moreover, an enhanced moving average filter and enhanced delayed signal cancellation algorithms, which are applicable for eliminating a group of selective harmonics with only one calculation block, are proposed. On this basis, both a comprehensive comparison and a quantitative evaluation of all of the aforementioned algorithms are made from several aspects, including response speed, required data storage size, sensitivity to sampling frequency, and elimination of random noise and harmonics. With the conclusions derived in this paper, better overall performance in terms of harmonic elimination can be achieved. In addition, experimental results under different conditions demonstrate the validity of this study.

도시철도 LED형 신호기 특허 시제품 제작.설치.시험에 관한 보고 (Metro LED Type Signal Test of a Patented Article Manufacture.Establishment.Examination Report)

  • 석태우;박종선;고양옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.885-889
    • /
    • 2006
  • Metro Subway System is widely known as the leader of public transportation in a metropolitan area. The signal interlocking is one of the most important organs that plays a major role in the system. By improving the quality of signal lights on the traffic system and keeping its maintenance on a high level will not only repair the current state, but it will also let the LED type signal semi-permanent. The device, which underwent a process of fine manufacture establishment and a close examination, obtained a patented article (2004, as a new device). Utilizing the equipment with cautious preservation on the system will enhance the current state of the signal device. Especially, the test for improvement and development based upon the technique that decreases the frequency of defect produced will further precipitate its efficiency. With authorization of imposing the LED lights on production, installment, and investigation of the system, the newly made equipment will bring improvement to the signal technology and to the industry at largest extent.

  • PDF

Collision Hazards Detection for Construction Workers Safety Using Equipment Sound Data

  • Elelu, Kehinde;Le, Tuyen;Le, Chau
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.736-743
    • /
    • 2022
  • Construction workers experience a high rate of fatal incidents from mobile equipment in the industry. One of the major causes is the decline in the acoustic condition of workers due to the constant exposure to construction noise. Previous studies have proposed various ways in which audio sensing and machine learning techniques can be used to track equipment's movement on the construction site but not on the audibility of safety signals. This study develops a novel framework to help automate safety surveillance in the construction site. This is done by detecting the audio sound at a different signal-to-noise ratio of -10db, -5db, 0db, 5db, and 10db to notify the worker of imminent dangers of mobile equipment. The scope of this study is focused on developing a signal processing model to help improve the audible sense of mobile equipment for workers. This study includes three-phase: (a) collect audio data of construction equipment, (b) develop a novel audio-based machine learning model for automated detection of collision hazards to be integrated into intelligent hearing protection devices, and (c) conduct field experiments to investigate the system' efficiency and latency. The outcomes showed that the proposed model detects equipment correctly and can timely notify the workers of hazardous situations.

  • PDF

최적화된 큐에서의 NMEA 멀티플렉서의 설계 및 구현 (Design and Implementation of NMEA Multiplexer in the Optimized Queue)

  • 김창수;정성훈;임재홍
    • 한국항해항만학회지
    • /
    • 제29권1호
    • /
    • pp.91-96
    • /
    • 2005
  • 현재 국내에서는 NMEA 멀티플렉서를 개발한 사례 띤 제품이 몇몇 업체가 있으나, 외국 제품보다 인지도 및 제품판매의 실적이 미비하다. 그러므로 외국의 고비용 장비를 수입하여 사용하거나, 멀티 포트를 이용하여 NMEA 신호를 전송하는 프로그램을 소프트웨어적으로 구현하여 사용하고 있다. 그러므로 고비용이 지출되거나, 각 응용프로그램마다 별도의 처리 부분을 작성해야하는 문제점이 있다. 또한, NMEA 신호를 출력하는 각각의 장비들은 제조회사 및 플랫폼이 다르므로 이중의 자원낭비 및 손실 등을 초래할 수 있다. 본 논문에서는 경제적으로 NMEA 멀티플렉서 모듈을 구현하기 위하여 가상 시스템을 구성하여 실험을 실시하였다. NMEA 신호를 입력하기 위해 각 장비들은 가상의 데이터를 가진 노드로 대치하여 멀티플렉서 구현을 위한 가상의 시스템을 구성하고, 여러 문제들을 보완하기 위하여 신뢰성 있는 처리방법과 고성능의 단일 하드웨어 모듈로서 독립적으로 동작할 수 있다. 최적화된 큐의 설계를 이용하여 모듈의 메모리 효율을 높이며, 주요 항해 장비인 자이로콤파스, 에코 사운드, GPS 등과 실시간으로 RS232 멀티포트를 통하여 입력되는 신호를 실제 PC에서 출력하여 통신의 정확성을 유지할 수 있는 NMEA 멀티플렉서의 설계 및 구현에 대하여 제안하였다.

Development of Anti-Spoofing Equipment Architecture and Performance Evaluation Test System

  • Jung, Junwoo;Park, Sungyeol;Hyun, Jongchul;Kang, Haengik;Song, Kiwon;Kim, Kapjin;Park, Youngbum
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제7권3호
    • /
    • pp.127-138
    • /
    • 2018
  • Spoofing attacks including meaconing can provide a bogus position to a victim GPS receiver, and those attacks are notably difficult to detect at the point of view on the receiver. Several countermeasure techniques have been studied to detect, classify, and cancel the spoofing signals. Based on the countermeasure techniques, we have developed an anti-spoofing equipment that detects and mitigates or eliminates the spoofing signal based on raw measurements. Although many anti-spoofing techniques have been studied in the literatures, the evaluation test system is not deeply studied to evaluate the anti-spoofing equipment, which includes detection, mitigation, and elimination of spoofing signals. Each study only has a specific test method to verify its anti-spoofing technique. In this paper, we propose the performance evaluation test system that includes both spoofing signal injection system and its injection scenario with the constraints of stand-alone anti-spoofing techniques. The spoofing signal injection scenario is designed to drive a victim GPS receiver that moves to a designed position, where the mitigation and elimination based anti-spoofing algorithms can be successively evaluated. We evaluate the developed anti-spoofing equipment and a commercial GPS receiver using our proposed performance evaluation test system. Although the commercial one is affected by the test system and moves to the designed position, the anti-spoofing equipment mitigates and eliminates the injected spoofing signals as planned. We evaluate the performance of anti-spoofing equipment on the position error of the circular error probability, while injecting spoofing signals.