A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids |
Xiong, Liansong
(State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University)
Zhuo, Fang (State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) Wang, Feng (State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) Liu, Xiaokang (State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) Zhu, Minghua (State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) Yi, Hao (State Key Lab of Electrical Insulation and Power Equipment, Xi'an Jiaotong University) |
1 | J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, C. Portillo, and M. ángeles, “Power-electronic systems for the grid integration of renewable energy sources: a survey,” IEEE Trans. Ind. Electron., Vol. 53, No. 4, pp. 1002-1016, Jun. 2006. DOI |
2 | L. Y. Yang, C. L. Wang, J. H. Liu, and C. X. Jia, “A novel phase locked loop for grid-connected converters under non-ideal grid conditions,” Journal of Power Electronics, Vol. 15, No. 1, pp. 216-226, Jan. 2015. DOI |
3 | J. S. Park, T. H. Nguyen, and D. C. Lee, “Advanced SOGI-FLL scheme based on fuzzy logic for single-phase grid-connected converters,” Journal of Power Electronics, Vol. 14, No. 3, pp. 598-607, May 2014. DOI |
4 | F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid aynchronization for distributed power generation systems,” IEEE Trans. Ind. Electron., Vol. 53, No. 5, pp. 1398-1409, Oct. 2006. DOI |
5 | C. H. G. Santos, R. V. Ferreira, S. M. Silva, and B. J. Cardoso Filho, “Fourier-based PLL applied for selective harmonic estimation in electric power systems,” Journal of Power Electronics, Vol. 13, No. 5, pp. 884-895, Sep. 2013. DOI |
6 | J. P. Lee, B. D. Min, T. J. Kim, D. W. Yoo, and J. Y. Yoo, “Active frequency with a positive feedback anti-islanding method based on a robust PLL algorithm for grid-connected PV PCS,” Journal of Power Electronics, Vol. 11, No. 3, pp. 360-368, May 2011. DOI |
7 | P. Mao, M. Zhang, and W. P. Zhang, “A canonical small-signal linearized model and a performance evaluation of the SRF-PLL in three phase grid inverter system,” Journal of Power Electronics, Vol. 14, No. 5, pp. 1057-1068, Sep. 2014. DOI |
8 | K. J. Lee, J. P. Lee, D. Shin, and D. W. Yoo, “A novel grid synchronization PLL method based on adaptive low-pass notch filter for grid-connected PCS,” IEEE Trans. Ind. Electron., Vol. 61, No. 1, pp. 292-301, Jan. 2014. DOI |
9 | A. Bechouche, D. O. Abdeslam, T. Otmane-Cherif, and H. Seddiki, “Adaptive neural PLL for grid-connected DFIG synchronization,” Journal of Power Electronics, Vol. 14, No. 3, pp. 608-620, May 2014. DOI |
10 | F. Gonzalez-Espín, E. Figueres, and G. Garcera, “An adaptive synchronous reference frame phase-locked loop for power quality improvement in a polluted utility grid,” IEEE Trans. Ind. Electron., Vol. 59, No. 6, pp. 2718-2731, Jun. 2012. DOI |
11 | F. D. Freijedo, J. Doval-Gandoy, O. Lopez, and E. Acha, “A generic open-loop algorithm for three-phase grid voltage/current synchronization with particular reference to phase, frequency, and amplitude estimation,” IEEE Trans. Power Electron., Vol. 24, No. 1, pp. 94-107, Jan. 2009. DOI |
12 | R. F. de Camargo and H. Pinheiro, “Synchronization method for three-phase PWM converters under unbalanced and distorted grid,” IEE Proceedings – Electric Power Applications, Vol. 153, No. 5, pp. 763-772, Sep. 2006. DOI |
13 | H. S. Song and K. Nam, “Instantaneous phase-angle estimation algorithm under unbalanced voltage-sag conditions,” IEE Proceedings – Generation, Transmission and Distribution, Vol. 147, No. 6, pp. 409-415, Nov. 2000. DOI |
14 | S.-J. Lee, J.-K. Kang, and S.-K. Sul, "A new phase detecting method for power conversion systems considering distorted conditions in power system," in IEEE 34th Industry Applications Conference, Vol. 4, pp. 2167-2172, 1999. |
15 | Y. F. Wang and Y. W. Li, “Grid synchronization PLL based on cascaded delayed signal cancellation,” IEEE Trans. Power Electron., Vol. 26, No. 7, pp. 1987-1997, Jul. 2011. DOI |
16 | P. Rodriguez, J. Pou, J. Bergas, I. Candela, R. Burgos, and D. Boroyevich, "Double synchronous reference frame PLL for power converters," in Proc. IEEE PESC., 2005, pp. 1415-1421. |
17 | P. Rodriguez, J. Pou, J. Bergas, and J. I. Candela, “Decoupled double synchronous reference frame PLL for power converters control,” IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 584-592, Mar. 2007. DOI |
18 | L. Wang, Q. Jiang, L. Hong, C. P. Zhang, and Y. D. Wei, “A novel phase-locked loop based on frequency detector and initial phase angle detector,” IEEE Trans. Power Electron., Vol. 28, No. 10, pp. 4538-4549, Oct. 2013. DOI |
19 | J. Svensson, “Synchronization methods for grid-connected voltage source converters,” IEE Proceedings – Generation, Transmission and Distribution, Vol. 148, No. 3, pp. 229-235, May 2001. DOI |
20 | F. D. Freijedo, J. Doval-Gandoy, O. Lopez, and C. Martinez-Penalver, "New algorithm for grid synchronization based on fourier series," in European Conference on Power Electronics and Applications, pp. 1-6, Sep. 2007. |
21 | A. Timbus, R. Teodorescu, F. Blaabjerg, and M. Liserre, "Synchronization methods for three phase distributed power generation systems: an overview and evaluation," in IEEE 36th Power Electronics Specialists Conference (PESC), pp. 2474-2481, Jun. 2005. |
22 | M. Li, Y. Wang, X. Fang, Y. Gao, and Z. A. Wang, “A novel single phase synchronous reference frame phase-locked loop with a constant zero orthogonal component,” Journal of Power Electronics, Vol. 14, No. 6, pp. 1334-1344, Nov. 2014. DOI |
23 | F. A. S. Neves, M. C. Cavalcanti, H. E. P. de Souza, and F. Bradaschia, “A generalized delayed signal cancellation method for detecting fundamental-frequency positive-sequence three-phase signals,” IEEE Trans. Power Del., Vol. 25, No. 3, pp. 1816-1825, Jul. 2010. DOI |
24 | H. J. Choi, S. H. Song, S. G. Jeong, J. Y. Choi, and I. Choy, “Enhanced dynamic response of SRF-PLL system for high dynamic performance during voltage disturbance,” Journal of Power Electronics, Vol. 11, No. 3, pp. 369-374, May 2011. DOI |
25 | Y. F. Wang and Y. W. Li, “Three-phase cascaded delayed signal cancellation PLL for fast selective harmonic detection,” IEEE Trans. Ind. Electron., Vol. 60, No. 4, pp. 1452-1463, Apr. 2013. DOI |
26 | Y. F. Wang and Y. W. Li, “Analysis and digital implementation of cascaded delayed-signal-cancellation PLL,” IEEE Trans. Power Electron., Vol. 26, No. 4, pp. 1067-1080, Apr. 2011. DOI |
27 | M. K. Ghartemani, “Linear and pseudolinear enhanced phased-pocked loop (EPLL) structures,” IEEE Trans. Ind. Electron., Vol. 61, No. 3, pp. 1464-1474, Mar. 2014. DOI |
28 | S. Golestan, M. Monfared, F. D. Freijedo and J. M. Guerrero, “Dynamics assessment of advanced single-phase PLL structures,” IEEE Trans. Ind. Electron., Vol. 60, No. 6, pp. 2167-2177, Jun. 2013. DOI |
29 | P. C. Krause, “The method of symmetrical components derived by reference frame theory,” IEEE Trans. Power App. Syst., Vol. PAS-104, No. 6, pp. 1492-1499, Jun. 1985. DOI |
30 | V. C. Strezoski, “Advanced symmetrical components method,” IET Generation, Transmission & Distribution, Vol. 5, No. 8, pp. 833-841, Aug. 2011. DOI |
31 | O. Vainio and S. J. Ovaska, “Noise reduction in zero crossing detection by predictive digital filtering,” IEEE Trans. Ind. Electron., Vol. 42, No. 1, pp. 58-62, Feb. 1995. DOI |
32 | R. M. S. Filho, P. F. Seixas, P. C. Cortizo, and L. A. B. Torres, “Comparison of three single-phase PLL algorithms for UPS applications,” IEEE Trans. Ind. Electron., Vol. 55, No. 8, pp. 2923-2932, Aug. 2008. DOI |
33 | T. Thacker, D. Boroyevich, R. Burgos, and F. Wang, “Phase-locked loop noise reduction via phase detector implementation for single-phase systems,” IEEE Trans. Ind. Electron., Vol. 58, No. 6, pp. 2482-2490, Jun. 2011. DOI |
34 | A. Luo, Y. D. Chen, Z. K. Shuai and C. M. Tu, “An improved reactive current detection and power control method for single-phase photovoltaic grid-connected DG system,” IEEE Trans. Energy Convers., Vol. 28, No. 4, pp. 823-831, Dec. 2013. DOI |