• 제목/요약/키워드: Signal Detector

검색결과 997건 처리시간 0.023초

Fluorimetric Determination of Dichloroacetamide by RPLC with Postcolumn Detection

  • Choi, Yong-Wook;Reckhow, David A.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.900-906
    • /
    • 2004
  • An RPLC-postcolumn detection method has been developed for the fluorimetric determination of dichloroacetamide (DCAD) in water. After ammonia and DCAD were separated on a $C_{18}$ nonpolar stationary phase with 2.5% methanol-0.02 M phosphate buffer at pH 3, the column eluant was reacted with post column reagents, o-phthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which was measured with a fluorescence detector ( ${\lambda}_{ex}$ = 363 nm, ${\lambda}_{em}$ = 425 nm). With the optimized conditions for RPLC and the postcolumn derivatization, the calibration curve was found to be linear in the concentration ranges of 0.5 and 20 ${\mu}$M for DCAD, and the detection limit for DCAD was 0.18 ${\mu}$M (23${\mu}$g/L). This corresponded to 18 pmol per 100 ${\mu}$L injection volume for a signal-to-noise ratio of 3, and the repeatability and reproducibility of this method were 1.0% and 2.5% for five replicate analyzes of 2 ${\mu}$M DCAD, respectively. The degradation yields DCAD to ammonia were 94 and 99%, and the percent recoveries of DCAD from 4 and 6 ${\mu}$M DCAD-spiked tap water were shown mean more than 97%.

축 방향 공간주파수 대역의 확장을 통한 고체 내부영상 개선 (The Enhancement of Inner-solid Image by the Bandwidth Increment of Vertically Spatial Frequency)

  • 구길모;김상백;김현;전계석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.176-180
    • /
    • 2001
  • In this paper, we have studies the images have been reconstructed by using combination of images which has been acquired by the variation of operating frequency. When inner images has been reconstructed, inner image has been superposition by surface state effect. In this case, image enhancement the phase object and enhance the contrast of inner image. In the result of the specimen for the round defect with 2mm diameter, for the types of the depth are 1.5mm, 2mm, 2.5mm, and 3mm, it has been show that the shape of defect has better than before this processing and phase contrast grow large twice. And we have constructed the acoustic microscope by using quadrature detector that is able simultaneously to acquired the amplitude and phase of the reflected signal. Father more we have studied the reconstruction method of the amplitude and phase images and the enhancement method of the defect images' contrast.

  • PDF

An Efficient Soft-Output MIMO Detection Method Based on a Multiple-Channel-Ordering Technique

  • Im, Tae-Ho;Park, In-Soo;Yoo, Hyun-Jong;Yu, Sung-Wook;Cho, Yong-Soo
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.661-669
    • /
    • 2011
  • In this paper, we propose an efficient soft-output signal detection method for spatially multiplexed multiple-input multiple-output (MIMO) systems. The proposed method is based on the ordered successive interference cancellation (OSIC) algorithm, but it significantly improves the performance of the original OSIC algorithm by solving the error propagation problem. The proposed method combines this enhanced OSIC algorithm with a multiple-channel-ordering technique in a very efficient way. As a result, the log likelihood ratio values can be computed by using a very small set of candidate symbol vectors. The proposed method has been synthesized with a 0.13-${\mu}m$ CMOS technology for a $4{\times}4$ 16-QAM MIMO system. The simulation and implementation results show that the proposed detector provides a very good solution in terms of performance and hardware complexity.

초음파를 이용한 수중 영상 버스트 전송 시스템을 위한 새로운 프레임 동기 방안 (A New Frame Synchronization Scheme for Underwater Ultrasonic Image Burst Transmission System)

  • 김승근;최영철;박종원;김시문;임용곤;김상태
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.336-340
    • /
    • 2003
  • The frame synchronization should be acquired before performing other data-aided receiving algorithms, such as data-aided channel equalizing, beam-forming and phase, symbol timing, and frequency synchronizing, since all of them are using preamble or training sequence to estimate the amount of error from the received signal. In this paper, we present a new frame synchronization scheme for underwater ultrasonic image burst transmission system, which computes the correlation between received symbol sequence and one CAZAC sequence, composed of the latter half of the first CAZAC sequence of preamble and the first half of the second CAZAC sequence of preamble and then compares a threshold value. If the correlation value is bigger than the threshold value, the frame detector determines that the frame synchronization is achieved at that sample.

  • PDF

Reference clock 생성기를 이용한 10:1 데이터 변환 2.5 Gbps 광 송신기 설계 (Design of a 2.5 Gbps CMOS optical transmitter with 10:1 serializer using clock generation method)

  • 강형원;김경민;최영완
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.159-165
    • /
    • 2005
  • The proposed optical transmitter is composed of FF(flip flop) , PLL (phase locked loop), reference clock generator, serializer and LD driver 10x250 Mb/s data arrays are translated to the 2.5 Gb/s data signal by serializer. In this case, 1 data bus is allocated usually as a reference clock for synchronization. In this proposed optical transmitter, 125 MHz reference clock is generated from 10x250 Mb/s data arrays by reference clock generator. From this method. absent of reference clock bus is available and more data transmission become possible. To achieve high speed operation, the serializer circuit is designed as two stacks. For 10:1 serialization, 10 clocks that have 1/10 lambda differences is essential, so the VCO (voltage controlled oscillator) composed of 10 delay buffers is designed. PLL is for runing at 250 MHz, and dual PFD(phase frequency detector) is adopted for fast locking time. The optical transmitter is designed by using 0.35 um CMOS technology.

  • PDF

SPD를 이용한 2.4 GHz PLL의 위상잡음 분석 (Phase Noise Analysis of 2.4 GHz PLL using SPD)

  • 채명호;김지흥;박범준;이규송
    • 한국군사과학기술학회지
    • /
    • 제19권3호
    • /
    • pp.379-386
    • /
    • 2016
  • In this paper, phase noise analysis result for 2.4 GHz PLL(phase locked loop) using SPD(sample phase detector) is proposed. It can be used for high performance frequency synthesizer's LO(local oscillator) to extend output frequency range or for LO of offset PLL to reduce a division rate or for clock signal of DDS(direct digital synthesizer). Before manufacturing, theoretical estimation of PLL's phase noise performance should be performed. In order to calculate phase noise of PLL using SPD, Leeson model is used for modeling phase noise of VCO(voltage controlled oscillator) and OCXO(ovened crystal oscillator). After theoretically analyzing phase noise of PLL, optimized loop filter bandwidth was determined. And then, phase noise of designed loop filter was calculated to find suitable OP-Amp. Also, the calculated result of phase noise was compared with the measured one. The measured phase noise of PLL was -130 dBc/Hz @ 10 kHz.

각 다중화 방식의 홀로그래픽 정보저장기기의 양방향틸트 보상시스템 설계 (Design of 2-axis compensation servo system for angle multiplexing Holographic Data Storage)

  • 임성용;김낙영;한초록;박경수;박노철;양현석;박영필
    • 정보저장시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.19-24
    • /
    • 2011
  • Holographic Data Storage System, one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume holograms in writing and retrieving process. Recently photopolymer with disc type substrate was selected as a media for the Holographic Data Storage System. The disc tilt occurs when the media rotates and the external disturbance applies. The disc tilt causes the change of the angle between the reference beam and the media, the data cannot be retrieved with the right angle or other data page is retrieved. The tilt is generated in a 2-axis direction (tangential, radial). The tangential tilt direction is the same with the multiplexing plane, while the radial tilt direction is a perpendicular to the multiplexing plane. In this research we propose 2-axis tilt angle servo system. The tilt errors are measured by using external photo detector and the additional red laser. Then the tangential direction tilt is compensated by using the galvano mirror. Also the radial direction tilt is compensated by the rotating prism between the relay lens in the reference field. Finally we confirm the compensation results through the Signal to Noise Ratio(SNR) and Bit Error Rate(BER).

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.116-131
    • /
    • 1972
  • Li$^{7}$ (p, n) Be$^{7}$ 원자핵반응에서 Li target의 두께와 입사양자의 에너지를 적절히 선정하므로써 1-n sec 파동 Van de Graaff 가속도로부터 keV 영역에서의 연속중성자spectrum을 발생시키고 92% 농축된 5mm 두께의 $B^{10}$ 판과 4개의 4"$\times$3" NaI (T1) 발광체로 이루어진 속중성자검출기를 이용 속중성자 비행시간법에 의한 중성자spectrometer 를 제작하였다. 장치의 에너지 분해능은 50 keV에서 0.3%보다 양호하며 신호대잡음비도 개량되었다. 이를 이용하여 몇가지 분석된 단일동위원소의 전단면적을 측정하고 R-matrix 전자계산 code로 분석하였다. 각 공명에 따르는 스핀식와 공명인수들을 찾아내었다.

  • PDF

수동형 원격탐지 FTIR 분광계의 Radiometric Calibration (Radiometric Calibration of FTIR Spectrometer For Passive Remote Sensing Application)

  • 김대성;박도현;최승기;나성웅
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.391-395
    • /
    • 2006
  • 본 논문에서는 온도 제어가 가능한 blackbody를 이용하여 수동형 FTIR 분광계의 radiometric calibration을 수행하고 타당성을 살펴보았다. Radiometric calibration은 분광계로 입사되는 radiance의 온도 변화에 대한 광 검출기의 파장 별 응답특성과 기기 내부에서 발생되는 온도 및 반사율에 의해 발생되는 측정 오차를 보정하여 Planck radiance로 변환하는 기법이다. 시료에 대한 calibration 과정을 수행한 스펙트럼을 spectral library와 비교한 결과, 흡수 스펙트럼의 파장 별 선폭과 상대적인 intensity가 매우 유사하게 나타났으며 입사 광원의 온도차와 비례하여 spectral intensity가 일정하게 증가됨을 확인할 수 있었다.

특이값분해 기반 동적의료영상 재구성기법의 특징 파악을 위한 시뮬레이션 연구 (Simulation Study for Feature Identification of Dynamic Medical Image Reconstruction Technique Based on Singular Value Decomposition)

  • 김도휘;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.119-130
    • /
    • 2019
  • Positron emission tomography (PET) is widely used imaging modality for effective and accurate functional testing and medical diagnosis using radioactive isotopes. However, PET has difficulties in acquiring images with high image quality due to constraints such as the amount of radioactive isotopes injected into the patient, the detection time, the characteristics of the detector, and the patient's motion. In order to overcome this problem, we have succeeded to improve the image quality by using the dynamic image reconstruction method based on singular value decomposition. However, there is still some question about the characteristics of the proposed technique. In this study, the characteristics of reconstruction method based on singular value decomposition was estimated over computational simulation. As a result, we confirmed that the singular value decomposition based reconstruction technique distinguishes the images well when the signal - to - noise ratio of the input image is more than 20 decibels and the feature vector angle is more than 60 degrees. In addition, the proposed methode to estimate the characteristics of reconstruction technique can be applied to other spatio-temporal feature based dynamic image reconstruction techniques. The deduced conclusion of this study can be useful guideline to apply medical image into SVD based dynamic image reconstruction technique to improve the accuracy of medical diagnosis.