• Title/Summary/Keyword: Shunt operation

Search Result 278, Processing Time 0.028 seconds

The Clinical Application and Results of Palliative Damus-Kaye-Stansel Procedure (고식적 Damus-Kaye-Stansel 술식의 임상적 적용 및 결과)

  • Lim, Hong-Gook;Kim, Soo-Jin;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul;Shinn, Sung-Ho;Yie, Kil-Soo;Lee, Jae-Woong;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Background: The Damus-Kaye-Stansel (DKS) procedure is a proximal MPA-ascending aorta anastomosis used to relieve systemic ventricular outflow tract obstructions (SVOTO) and pulmonary hypertension. The purpose of this study was to review the indications and outcomes of the DKS procedure, including the DKS pathway and semilunar valve function. Material and Method: A retrospective review of 28 patients who underwent a DKS procedure between May 1994 and April 2006 was performed. The median age at operation was 5.3 months ($13\;days{\sim}38.1\;months$) and body weight was 5.0 kg ($2.9{\sim}13.5\;kg$). Preoperative pressure gradients were $25.3{\pm}15.7\;mmHg$ ($10{\sim}60\;mmHg$). Eighteen patients underwent a preliminary pulmonary artery banding as an initial palliation. Preoperative main diagnoses were double outlet right ventricle in 9 patients, double inlet left ventricle with ventriculoarterial discordance in 6,. another functional univentricular heart in 5, Criss-cross heart in 4, complete atrioventricular septal defect in 3, and hypoplastic left heart variant in 1. DKS techniques included end-to-side anastomosis with patch augmentation in 14 patients, classical end-to-side anastomosis in 6, Lamberti method (double-barrel) in 3, and others in 5. The bidirectional cavopulmonary shunt and Fontan procedure were concomitantly performed in 6 and 2 patients, respectively. Result: There were 4 hospital deaths (14.3%), and 3 late deaths (12.5%) with a follow-up duration of $62.7{\pm}38.9$ months ($3.3{\sim}128.1$ months). Kaplan-Meier estimated actuarial survival was $71.9%{\pm}9.3%$ at 10 years. Multivariate analysis showed right ventricle type single ventricle (hazard ratio=13.960, p=0.004) and the DKS procedure as initial operation (hazard ratio=6.767, p=0.042) as significant mortality risk factors. Four patients underwent staged biventricular repair and 13 received Fontan completion. No SVOTO was detected after the procedure by either cardiac catheterization or echocardiography except in one patient. There was no semiulnar valve regurgitation (>Gr II) or semilunar valve-related reoperation, but one patient (3.6%) who underwent classical end-to-side anastomosis needed reoperation for pulmonary artery stenosis caused by compression of the enlarged DKS pathway. The freedom from reoperation for the DKS pathway and semilunar valve was 87.5% at 10 years after operation. Conclusion: The DKS procedure can improve the management of SVOTO, and facilitate the selected patients who are high risk for biventricular repair just after birth to undergo successful staged biventricular repair. Preliminary pulmonary artery banding is a safe and effective procedure that improves the likelihood of successful DKS by decreasing pulmonary vascular resistance. The long-term outcome of the DKS procedure for semilunar valve function, DKS pathway, and relief of SVOTO is satisfactory.

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF

Reoperations after Fontan Procedures (폰탄 술식 후에 시행한 재수술)

  • Lee, Cheul;Kim, Yong-Jin;Lee, Jeong-Ryul;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.457-462
    • /
    • 2003
  • Background: Surgical results of the Fontan procedures in patients with a single ventricle have improved. As the perioperative mortality continues to decline and late outcome is forthcoming, attention is now being directed toward late complications of the Fontan procedures. We retrospectively analyzed our experience with reoperations after Fontan procedures. Material and Method: Between January 1988 and December 2002, 24 patients underwent reoperations after Fontan procedures. The median age at Fontan procedures and reoperation was 3.3 years and 9.2 years, respectively. Types of initial Fontan procedures were atriopulmonary connection (n=11), lateral tunnel Fontan (n=11), and extracardiac conduit Fontan (n=2). Indications for reoperation included atrioventricular valve regurgitation (n=7), atrial arrhythmia (n=8), Fontan pathway stenosis (n=7), residual right-to-left shunt (n=5), etc. Result: Procedures performed at reoperation included atrioventricular valve replacement (n=6), conversion to lateral tunnel Fontan (n=5), conversion to extracardiac conduit Fontan (n=3), cryoablation of arrhythmia circuit (n=7), etc. There was no operative mortality. There were 2 late deaths. Mean follow-up duration was 2.7$\pm$2.1 years. All patients except two were in NYHA class I at the latest follow-up. Among 8 patients with preoperative atrial arrhythmia, postoperative conversion to normal sinus rhythm was achieved in 7 patients. Conclusion: Reoperations after Fontan procedures could be achieved with low mortality and morbidity. Reoperation may lead to clinical improvement in patients with specific target conditions such as atrioventricular valve regurgitation, refractory atrial arrhythmia, or Fontan pathway stenosis, especially in patients with previous atriopulmonary connection.

Echocardiographic Parameters of Pulmonary Atresia with Intact Ventricular Septum(PA/IVS) (심실 중격 결손을 동반하지 않은 폐동맥 폐쇄 환아에서의 심초음파 계측치)

  • Lee, Young Seok;Kim, Yeo Hyang;Hyum, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.484-489
    • /
    • 2003
  • Purpose : To understand morphologic and hemodynamic variations in patients with pulmonary atresia with intact ventricular septum(PA/IVS), and to decide the best treatment modalities, we measured right ventricular volume, inflow, and outflow valvular annulus size in these patients and compared them with those of normal newborns. Methods : Eight patients with PA/IVS diagnosed by echocardiography from January to December 2001 were enrolled in this study. Among the total eight patients, five were male and three were female. The mean age of patients was 6.9 days(1-34 days), and the mean body weight was 3,343 gm (2,970-4,000 gm). Ten fullterm newborn infants with sepsis or hyperbilirubinemia without heart disease were enrolled as a control group. Echocardiographic and Doppler studies using Acuson Aspen (7Mh probe) were recorded on super-VHS videotape and later on, with review mode. We measured volumes of right and left ventricles, aortic, pulmonic, mitral and tricuspid valvular annulus sizes using an installed program, and then these parameters were compared with those of the control group. Results : Mean Z-value of tricuspid valvular annulus in PA/IVS was $-3.69{\pm}2.80$(-8.4--0.45), and tricuspid/mitral valvular annulus size ratio $0.68{\pm}0.15$(0.43--0.84). The more the tricuspid/mitral valvular annulus size ratio, the more Z-value of tricuspid valvular annulus(P=0.003, r=0.885). Those patients who underwent pulmonary valvuloplasty(balloon or surgical) had a tendency toward larger volume of the right ventricle, more Z-value of pulmonic and tricuspid valvular annulus, and more tricuspid/mitral valvular annulus size ratio than those patients who underwent a shunt operation. Conclusion : Compared to a measurement of the volume of the right ventricle, measurements of tricuspid/mitral valvular annulus size ratio and Z-value of tricuspid valvular annulus may be easier and better parameters to decide the treatment method and to predict prognosis in PA/IVS patients.

Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava

  • Lee, Sub;Kim, Han-Woong;Kang, Hyoung-Seok;Bae, Chi-Hoon;Jheon, Sang-Hoon;Kwon, Oh-Choon;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.672-679
    • /
    • 2001
  • Background: Surgical correction of partial anomalous pulmonary venous connection to the superior vena cava has been associated with postoperative venous obstruction and sinus node dysfunction. In this paper we describe our current approach and its short-term results. Material and Method: Between April 1999 and January 2000, 5 consecutive patients, ranging from 2 months to 66 years old, underwent corrective operation for partial anomalous pulmonary venous connection to the superior vena cava at Sejong General Hospital and Daegu Catholic University Medical Center. Surgical correction involved diversion of the pulmonary venous drainage to the left atrium using a right atrial flap(2 patients) or prosthetic patch(3 patients) with division of the superior vena cava superior to the restore site of the pulmonary veins and reimplantation on the right atrial appendage to restore systemic venous drainage. Result: All patients were discharged between postoperative day 9 and 15 without complications. One Russian boy returned to his country, therefore, he was lost to follow-up after discharge. Remaining 4 patients were asymptomatic and in normal regular sinus rhythm at a mean follow-up of 17.75$\pm$4.27 months. Follow-up echocardiographic study (range, 12 to 24 months) revealed no incidence of narrowing of the venous pathways or of residual shunt. Conclusion: Our current approach is relatively simple and reproducible in achieving unobstructive pulmonay venous and SVC pathways. By avoiding incision across the cavoatrial junction, surgical injury to the sinus node and its artery may be minimized. The presented surgical technique can be safely and effectively applied to the selected patients.

  • PDF

Aortopulmonary Window (대동맥폐동맥창)

  • Kim Dong-Jin;Min Sun-Kyung;Kim Woong-Han;Lee Jeong-Sang;Kim Yong-Jin;Lee Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.275-280
    • /
    • 2006
  • Background: Aortopulmonary window (APW) is a very rare congenital heart anomaly, often associated with other cardiac anomalies. It causes a significant systemic to pulmonary artery shunt, which requires early surgical correction. Accurate diagnosis and surgical correction will bring good outcomes. The purpose of this study was to describe our 20-year experience of aortopulmonary window. Material and Method: Between March 1985 and January 2005, 16 patients with APW underwent surgical repair. Mean age at operation was $157.8{\pm}245.3$ ($15.0{\sim}994.0$) days and mean weight was $4.8{\pm}2.5$ ($1.7{\sim}10.7$) kg. Patent ductus arteriosus (8), atrial septal defect (7), interruptedaortic arch (5), ventricular septal defect (4), patent foramen ovate (3), tricuspid valve regurgitation (3), mitral valve regurgitation (2), aortic valve regurgitation (1), coarctation of aorta (1), left superior vena cavae (1), and dextrocardia (1) were associated. Repair methods included 1) division of the APW with primary closure or patch closure of aorta and pulmonary artery primary closure or patch closure (11) and 2) intra-arterial patch closure (3). 3) Division of the window and descending aorta to APW anastomosis (2) in the patients with interrupted aortic arch or coarctation. Result: There was one death. The patient had 2.5 cm long severe tracheal stenosis from carina with tracheal bronchus supplying right upper lobe. The patient died at 5th post operative day due to massive tracheal bleeding. Patients with complex aortopulmonary window had longer intensive care unit and hospital stay and showed more morbidities and higher reoperation rates. 5 patients had reoperations due to left pulmonary artery stenosis (4), right pulmonary artery stenosis (2), and main pulmonary artery stenosis (1). The mean follow-up period was $6.8{\pm}5.6$ (57.0 days$\sim$16.7 years)years and all patients belonged to NYHA class 1. Conclusion: With early and prompt correction of APW, excellent surgical outcome can be expected. However, optimal surgical method needs to be established to decrease the rate of stenosis of pulmonary arteries.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.