• Title/Summary/Keyword: Sewage Disposal

Search Result 164, Processing Time 0.024 seconds

Sewage disposal system management policy in Korea (우리나라의 하수도사업현황 및 시책방향)

  • 류지영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 1995
  • We had passed through a serious water pollution with a rapid urbanization and industrialization in the 1960's. Seoul Chunggyechun Sewage Disposal System set uP in 1966 and finished in 1976, as the first sewage disposal system in Korea, had covered only 4 percentage of the sewage disposal system per capita for 10 years. Through holding the Asian Games in 1986 and the Olympic Games in 1988, we expanded the sewage disposal system so that it became increased 18 percentage of the population in 1986. Finally, we have installed about 60 sewage disposal system by 1994 for a large environmental investment which was critically caused by "Phenol Accident in Nakdong River" . Now, the sewage disposal system per capita covers 42 percentage and the activity for water quality improvement is going on rapidly. The method of sewage disposal is mainly "activated sludge process" . However, the technical ability for the sewage disposal has largely developed since 1991 so the "extended aeration process" is used in Po$\v{u}$n, Tangyang, Mun$\v{u}$i, "rotating biological contact process" in Onch$\v{u}$ng, Pukok, and "oxidation ditch process" in K$\v{o}$ch'ana.

  • PDF

Development of an Environmentally Friendly Sewage Disposal Model for Agricultural and Fishing Village Areas (자연친화형 농어촌 하수처리장 모델개발)

  • Chung, Dong-Yang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.2 no.1
    • /
    • pp.10-19
    • /
    • 1999
  • In 1991, the ministry of Gov't. Administration and Home Affairs set up a minimum of one sewage disposal plant in each province. By 1995, 264 models of the capillary infiltration method were set up in 331(78%) villages and the contact oxidation method was set up in 52 places. Since the Gov't. sent a letter to each responsible officer across the country stating their disapproval of the capillary infiltration method, the environmentally friendly sewage disposal system has not been diffused. The current model(mechanical sewage disposal) being used, in agricultural and fishing villages, costs too much for maintenance and operation(\50,000 per capita per year). In particular, because of the difference in sewage characteristics of agricultural and fishing villages from urban sewage, the efficiency of the disposal system is very low. Also, because of the growing need for more disposal plants, the Gov't. is looking for cheaper alternatives. This study has analyzed 2 kinds of sewage disposal. The first is used widely in agricultural and fishing villages in Germany. The second is used widely in similar areas of Korea. It has intended to analyze the characteristics, merits and defects of the sewage disposal water plants and pebbles model which is used widely in Germany and developed compatibly for Korea.

  • PDF

Comparative Analysis on NIMBY Facility and Location - Suyeong·Nambu·Haeundae Sewage Disposal Plants Cases - (기피시설 입지의 지역별 비교 및 결정요인 분석 - 수영·남부·해운대하수처리장 사례중심 -)

  • Choi, Yeol;Choi, Jae Do
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.491-497
    • /
    • 2006
  • The goal of this research is to explore the opinions of the resident's neighboring within sewage disposal plants, to investigate the differences in accordance with each location of sewage disposal plants, and to examine the determinants to impact on the sewage disposal plants. The multivariate analysis of variance model and regression model are employed as the empirical analysis for this research. The major findings are as follows; as a rule, most of residents represented the sewage disposal plants are essential public facilities. The sewage disposal plants could be positively considered under proper compensation and negotiation, It is found that the satisfaction level against accomplishing process of the sewage disposal plants facilities are very low. In addition, it was revealed that the determinants to impact on the sewage disposal plants showed differently according to each current location of sewage disposal plants. It means that there are no absolutely concrete reasons to oppose the sewage disposal plants and they can be somewhat different by the each local characteristics. Therefore, these findings provide for the policy makers related with the NIMBY facilities including the sewage disposal plants with valuable information.

The Infiltration Velocity of a Sewage Disposal System with Water Plant and Gravel Bed (수초·골재 하수처리장의 투수속도)

  • Chung, Dong Yang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.29-34
    • /
    • 2003
  • This paper describes the effects of sewage amount, temperature, and years in operation on the infiltration rate of a sewage disposal system. The self-purifying sewage disposal system, which is typically used in rural areas, consists of reeds and fine gravel. Water plants are planted on the gravel bed which provides the habitat for microbes. The basic process is that the gravel bed filters incoming sewage. Thus this system requires the smooth flow of sewage through the gravel. However, the efficiency of the disposal system will be lowered if the gravel bed is clogged with sewage sludge. A three year study shows that infiltration rate slows down significantly until the 7th day, depending on the sewage amount and the temperature. After the 7th day, the infiltration rate remains almost constant. In addition, the infiltration rate decreases as the temperature falls. It also decreases as the number of years in operation increase. But there is no significant change in the infiltration rate after the 7th day, independent of the temperature, the sewage amount, and years in operation. In order to take advantage of high infiltration rate, which improves the efficiency of the disposal system in its early stages, having two gravel beds and using them alternatively will be efficient. This operation method is called intermittent load and makes the disposal system last longer. The water plant roots above the gravel bed make the effective filtration possible because they delay accumulation of the sewage sludge and stabilize the filtration ability.

Treatment, Disposal and Beneficial Use Option for Sewage Sludge (하수슬러지 처리기술 동향 및 최적화 처리방안)

  • Choe, Yong-Su
    • 수도
    • /
    • v.24 no.5 s.86
    • /
    • pp.29-44
    • /
    • 1997
  • Sewage sludge produced in Korea was 1,275,800 tons (dewatered sludge cake) per year in 1996, which is 3,495 tons per day, 0.303% of 11,526,100 tons per day of sewage treated in 79 sewage treatment plants. Sludge production has been and will be increasing in accordance with construction of new facilities for sewage treatment. Most of the sludge is currently disposed by landfill and ocean dumping, but it is becoming difficult to find suitable sites for landfill, particularly in big cities such as Seoul. In addition, rapid increase of landfill cost is anticipated in a near future. Current trend for sludge disposal in advanced countries is land application. Over the past 10 to 20 years in the United States, sludge management practices have changed significantly, moving from disposal to beneficial use. They use biosolid for utilization instead of sludge for disposal. Under the Clean Water Act of 1972, amended in 1987 by Congress, the U.S. EPA was required to develop regulations for the use and disposal of sewage sludge. The EPA assessed the potential for pollutants in sewage sludge to affect public health and the environment through a number of different routes of exposure. The Agency also assessed the potential risk to human health through contamination of drinking water sources or surface water when sludge is disposed on land. The Final Rules were signed by the EPA Administrator and were published (Federal Register, 1993). These rules state that sewage sludge shall not be applied to land if the concentration of any pollutant in the sludge exceeds the ceiling concentration. In addition, the cumulative loading rate for each pollutant shall not exceed the cumulative pollutant loading rate nor should the concentration of each pollutant in the sludge exceed the monthly average concentration for the pollutant. The annual pollutant loading rate generally applies to applications of sewage sludge on agricultural lands. The most popular beneficial use of sewage sludge is land application. The sludge has to be stabilized for appling to land. One of the stabilization process for sewage sludge is lime stabilization process. The stabilization process is consisted of the stabilizing process and the drying process. Stabilization reactor can be a drum type reactor in which a crossed mixer is equipped. The additive agents are a very reactive mixture of calcium oxide and others. The stabilized sludge is dried in sun drier or rotary kiln.

  • PDF

Development of Automatic Manufacturing System of FRP Sewage Disposal Tanks for Safety (작업자 안전을 위한 FRP 정화조 제조의 자동화 시스템 개발)

  • 박강;한영근;박주식;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.37-47
    • /
    • 2004
  • The processes of manufacturing FRP sewage disposal tanks are very dangerous and hazardous jobs for workers because of large size and heavy weight of the tank, toxic fiberglass dust, nasty smell, and dangerous tools such as hand-grinders. This paper introduces an automatic manufacturing system of the FRP sewage disposal tank to enhance the safety of workers. The system consists of 3 components: the FRP body rotation jig, the automatic manhole cutting machine, the automatic sanding processing machine. The safety of workers and working environment are greatly improved, because the dangerous jobs are automatized and the toxic fiberglass dust is automatically collected. Also, the productivity is greatly improved and the cost is reduced.

The Impact of a Basic Environmental Facility Siting on Land Prices : A Case of Sewage Disposal Plant (환경기초시설의 입지가 지가에 미치는 영향 : 하수처리장을 사례로)

  • JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.170-180
    • /
    • 2017
  • This research analyzed the effect of a basic environmental facility siting on the difference in land prices using a case study of Jisan sewage disposal plant in Daegu metropolitan city. To do so, two buffer zones were generated around Jisan sewage disposal plant to 400m at an interval of 200m as a setback distance and 822 officially announced individual land prices were acquired from Korea Ministry of Land, Infrastructure and Transport(MOLIT). Paired samples t-test was performed to compare the mean difference in land prices before and after Jisan sewage disposal plant siting. Results show that the mean land price from each buffer zone was slightly increased after the siting and the difference was statistically significant. Also, the results indicate that the mean land price within 200m was lower than that between 200m and 400m before the siting while there was not different in the mean land price for both buffer zones after the siting. Because Jisan sewage disposal plant did not have a stench and a larger capacity and its surrounding areas were blended by commercial and residential uses, a sewage disposal plant siting had little effect on the fall in land prices unlike previous studies. The findings from this research will provide new reference data for local government and local people with conflicting views on the siting of a basic environmental facility.

Water Quality Variations in Jinhae Bay by Dredging & Operating the Sewage Disposal Plant (마산만 준설사업 및 하수처리장 가동에 따른 진해만의 수질변동)

  • YOON SUK-JIN;LEE IN-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.117-122
    • /
    • 2004
  • This study investigates the spatial and temporal distribution characteristics and relationships among water quality parameters, which based on 6 years' data(from 1989 to 1994) measured at 16 stations on Jinhae Bay. The results of these analysis, monthly variations range between surface and bottom layer of water quality had a tendency to increase and decrease, and appeared to be at the maximum value in August. The relationships between concentration of COD ana nutrients(DIN and DIP), which obtained by correlation analysis of water quality, were shown $85\%$ and $74\%$, respectively. Using the cluster analysis to develop the division of the sea basin by the dendrogram, before and after dredging of Masan bay and operating a sewage disposal plant, the variation characteristics of water quality of Jinhae Bay were discussed. Through it, we can see the serious pollution of northen sea basin of Jinhae Bay(B2) although dredging Masan bay and operating the sewage disposal plant. As the results, it doesn't appear the improvement effect of water quality in spite of carrying out the effort of water quality improvement.

  • PDF

Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant (지하 수처리시설 유지관리층 환기설비의 성능평가)

  • Kang, Han-Gi;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.

Study on Design Method of Control & Monitoring System by Module Network Constitution in Sewage Disposal Facility (오수처리시설의 모듈 네트워크 구성에 의한 제어 및 감시 시스템의 설계방법에 관한 연구)

  • Park, Seung-Hwan;Ku, Ja-Yl;Chae, Su-Kuern
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.66-72
    • /
    • 2009
  • In field of environments, the control and monitoring devices for sewage disposal facilities have been developed to overcome a problem of the water contamination according to industrialization and urbanization. In order to control and monitor the driving motor and the surroundings states of the sewage disposal facilities installed in local stations, this paper presents the design method of efficient module system interconnected by internal network with serial interface. It is expected that the proposed method in this paper is able to provide the more adaptive and flexible design technique for the specification of condition and factors needed in the fast-changed environment market.