• Title/Summary/Keyword: Sep-pak $C_{18}$

Search Result 87, Processing Time 0.026 seconds

Analysis of Preservatives in Flavor-Containing Foods (향기성분이 있는 식품의 보존료 분석)

  • Kim, Jin-Ho;Kim, Hyeon-Wee;Cha, Ik-Soo;Lee, Yoon-Kyoung;Park, Ki-Moon
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.1033-1037
    • /
    • 1996
  • An attempt was made to analyze preservatives in flavor-containing curry and tomato ketchup without interference due to their of flavor components. Samples were steam-distillated and extracted with ether. Sorbic acid, benzoic acid, dehydroacetic acid and salicylic acid were analyzed by GC with capillary column. Benzoic acid and dehydroacetic acid in curry were interfered by flavor components, but there was no interference in case of tomato ketchup. Samples were pretreated with Sep-Pak $C_{18}$ cartridge and analyzed with HPLC to avoid any interference due to flavor components. The recoveries by HPLC were higher than those by GC. Recoveries of sorbic acid, benzoic acid and salicylic acid from curry were 79.9%, 71.2% and 64.4%, respectively. Recoveries of sorbic acid, benzoic acid and salicylic acid from tomato ketchup were 83.4%, 87.8% and 77.7%, respectively.

  • PDF

Determination of several families of antibacterial agent residues in fish by disk assay (미생물학적 방법에 의한 어체내 잔류 항균물질의 계열별 동정시험)

  • Jung, Sung-Hee;Kim, Jin-Woo
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.125-135
    • /
    • 1997
  • The possibility of identification of families of antibacterial agent residues in fish tissue was studied by disk assay using three test organisms, Bacillus subtilis BGA, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778. In the present method, a simple clean-up procedure was performed to obtain the aqueous solution from homogenized flounder muscle sample(10g) in Mcilvaine buffer. Then, aqueous solution was fractionated into A and B to be used in disk assay by choloroform and Sep-Pak $C_{18}$ cartridge column after being defatted in hexane. The chloroform layer of fraction A was used for the analysis of macrolide antibiotics(ML), sulfa drugs(SA), chloramphenicol(CP), and quinolone antibiotics(QN). Adsorbed materials to Sep-Pak $C_{18}$ of fraction B were also employed for the analysis of penicillins(PC), tetracyclines(TC), and nitrofuran derivatives(NF) Minimun-detectable concentrations by the present method were, $0.1{\mu}g$/g for oxytetracycline, tetracycline, doxycycline, spiramycin and ciprofloxacin, $0.025{\mu}g$/g for erythromycin and ampicillin, $1.0{\mu}g$/g for sodium nifurstyrenate and florfenical, $0.25{\mu}g$/g for sulfamonomethoxie and sulfadimethoxine, $2.5{\mu}g$/g for oxolinic acid and flumequine, and $15{\mu}g$/g for piromidic acid, respectively. Three test organisms showed different sensitivity patterns for each family of antibacterial agent. Sensitivity patterns were B. cereus > B. subtilis > M. luteus for TC and NF, M. luteus > B, subtilis > B. cereus for ML and PC, B. cereus = B. subtilis > M. luteus for CP and QN, and B. subtilis > B. cereus=M. luteus for SA. The present method utilizing these characteristics could be useful as a routine screening test for the determination of family of antibacterial agent residues in fish tissue.

  • PDF

Development of Radiosynthetic Methods of 18F-THK5351 for tau PET Imaging (타우 PET영상을 위한 18F-THK5351의 표지방법 개발)

  • Park, Jun-Young;Son, Jeong-Min;Chun, Joong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.51-54
    • /
    • 2018
  • Purpose $^{18}F-THK5351$ is the newly developed PET probe for tau imaging in alzheimer's disease. The purpose of study was to establish the automated production of $^{18}F-THK5351$ on a commercial module. Materials and Methods Two different approaches were evaluated for the synthesis of $^{18}F-THK5351$. The first approach (method I) included the nucleophilic $^{18}F$-fluorination of the tosylate precursor, subsequently followed by pre-HPLC purification of crude reaction mixture with SPE cartridge. In the second approach (method II), the crude reaction mixture was directly introduced to a semi-preparative HPLC without SPE purification. The radiosynthesis of $^{18}F-THK5351$ was performed on a commercial GE $TRACERlab^{TM}$ $FX-_{FN}$ module. Quality control of $^{18}F-THK5351$ was carried out to meet the criteria guidelined in USP for PET radiopharmaceuticals. Results The overall radiochemical yield of method I was $23.8{\pm}1.9%$ (n=4) as the decay-corrected yield (end of synthesis, EOS) and the total synthesis time was $75{\pm}3min$. The radiochemical yield of method II was $31.9{\pm}6.7%$ (decay-corrected, n=10) and the total preparation time was $70{\pm}2min$. The radiochemical purity was>98%. Conclusion This study shows that method II provides higher radiochemical yield and shorter production time compared to the pre-SPE purification described in method I. The $^{18}F-THK5351$ synthesis by method II will be ideal for routine clinical application, considering short physical half-life of fluorine-18 ($t_{1/2}=110min$).

Study on analytical method of residual macrolide antibiotics in livestock products by LC/MS (LC/MS를 이용한 축산물 중 잔류 마크로라이드계 항생물질 분석법 연구)

  • 황래홍;윤은선;김연주;김동언;양윤모;이정학;이병동
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • This study was carried out to confirm analytical method of residual macrolides in livestock products by LC/MS. 1. Macrolides were analyzed by LC/MS on XTerra C$\sub$18/ column with 0.1% TFA(trifluoroacetic acid)-methanol in a gradient mode as mobile phase, and that were identified by positive chemical ionization with selective ion monitoring at 50~1000 mass range. 2. Residual macrolides were extracted from tissue with acetonitrile, and the extract is purified with a Sep-pak C$\sub$18/ cartridge, and elute macrolides with 0.1M methanolic ammonium acetate. 3. The procedure confirms the presence of each macrolide at 50$\mu\textrm{g}$/kg in spiked sample.

The Simultaneous Analysis of Oxytetracycline, Chloramphenicol and Sulfamethoxazole in Pork by HPLC (HPLC를 이용한 돈육 중의 Oxytetracycline, Chloramphenicol 및 Sulfamethoxazole의 동시검출)

  • 조혜연;조진국;이치호
    • Food Science of Animal Resources
    • /
    • v.21 no.1
    • /
    • pp.64-70
    • /
    • 2001
  • The extraction procedure and HPLC condition were modified to analyze the residues of oxytetracycline, sulfamethoxazole and chloramphenicol in pork, simultaneously. The antibacterial agents in pork were extracted with 0.02M EDTA-Mcilivine buffer:ethanol:acetonitrile (5:3:2). After the removal of fat with n-hexane, the extracts were evaporated and purified with Sep-pak $C_{18}$ cartridge column using 0.01M oxalic acid 0.1% (v/v) triethylamine (TEA) in acetonitrile. The peak of antibacterial agents was detected with $\mu$ Bondapak C18 column, UV detector (280nm) and 0.01M oxalic acid: methanol: acetonitrile (7.5:2.0:0.5). Detection limits for three antibacterial standards were 0.03 ppm. Calibration curves were linear between 0.03 and 2.0 ppm (R$^2$>0.999). When spiked the level of 1.0 ppm of oxytetracycline, sulfamethoxazole and chloramphenicol into meats, the recoveries from meats were 77.3%, 79.7% and 59.3%, respectively. These results showed that the modified extraction method provided good analytical resolution and the recoveries of the above antibacterial agents in meats.

  • PDF

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

HPLC Determination of Carboxyl Group Using 2-Bromoacetyltriphenylene as a Pre-labeling Reagent - Separative determination of bile acids by HPLC (2-Bromoacetyltriphenylene 유도체화제를 이용한 카르복실기 함유 성분의 분석법 (II) - 담즙산 혼합물의 HPLC에 의한 분리정량)

  • 박만기;정해수;양호길
    • YAKHAK HOEJI
    • /
    • v.31 no.2
    • /
    • pp.105-111
    • /
    • 1987
  • A high performance liquid chromatographic method was developed for the simultaneous determination of free and glycine conjugated bile acids. Free and glycine conjugated bile acids were extracted from bear gall bladder by methanol and from serum using a Sep-pak $C_{18}$ catridge. The extracted bile acids were labeled with 2-bromoacetyltriphenylene in acetonitrite using 18-crown-6-ether as a catalyst. Derivatized bile acids were separated from the individual bile acids on a reversedphase column (Chemcosorb 5-ODS-H) using acetonitrile-methanol-water(10:50:30) as a mobile phase and monitored by an UV-detector at 254nm. Linearities of calibration curve were obtained between 4 ng and 24 ng, and recoveries from bear gall bladder sample were higher than 94%.

  • PDF

Determination of blood concentration of higenamine by high pressure liquid chromatography

  • Park, Sun-Oak;Hong, Chang-Yee;Paik, Seung-Whan;YunChoi, Hye-Sook
    • Archives of Pharmacal Research
    • /
    • v.10 no.1
    • /
    • pp.60-66
    • /
    • 1987
  • A procedure utilizing high pressure liquid chroatography coupled with UV detection is described for the determination of blood concentration of higenamine. Deproteinized serum was pretreated with$C_{18}$(Sep-pak $C_{18}$ cartridge) and the 70% EtOH eluent was applied onto a reversed-phase column ($\mu$ Bondapak $C_{18}]$) with a 15% acetonitrile in 0.05 N $NaH_2$$PO_4$-trichloroacetic acid mixed buffer (pH 2.8) as a mobile phase. With the UV detection at 232 nm, the retention times of higenamine and 1, 2, 3, 4-tetrahydropapaveroline, an internal standard, were 5.2 min and 3.9 min respectively. The blood concentration of higenamine was meausred at regular intervals after i. v. injection of higenamine to rabbit. A drastic decrease in higenamine concentration to 30% of the maximum value obtained immediately after the injection, was observed during the first 1-2 min period and thereafter the rate of decrease was slowed down. The analytical result seemed to coincide with the pharmacological effect of higenamine exerting the maximum chronotropic and hypotensive effect at the completion of the injections which were progressively recovered.

  • PDF

Determination of alkylphenol ethoxylate in water by high performance liquid chromatography/electrospray ionization/mass spectrometry (HPLC/ESI/MS를 이용한 물 중의 알킬페놀에톡실레이트 분석)

  • Lee, Jeongae;Park, Song-Ja;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.263-270
    • /
    • 2004
  • A method is described for the analysis of short-chain alkylphenol ethoxylates (APEOs), 4-octylphenol-di-ethoxylate (OP2EO) and 4-nonylphenol-di-ethoxylate (NP2EO), in drinking water or wastewater using reversed phase high-performance liquid chromatography with electrospray ionization mass spectrometry. The solvent system was water and methanol containing $10{\mu}M$ trifluoroacetic acid as an ionization solvent. We acidified 1 L of water samples to less than pH 2 with concentrated $H_2SO_4$ and loaded onto Sep-Pak $C_{18}$, and eluted with acetone. The calibration of OP2EO and NP2EO was performed for the concentration range from 20 to 500 ng/L and the correlation coefficients were 0.999 and 0.990, respectively. The limits of detection were 20 ng/L (OP2EO) and 50 ng/L (NP2EO) at a signal-to-noise ratio of 3. Accuracy and precision of this analytical method were 85.8 ~ 122.1% and 8.2 ~ 18.8%, respectively. The proposed method allowed a sensitive and rapid detection of OP2EO and NP2EO and it could be applied for monitoring of APEOs from environmental samples.

Comparison of Sesquiterpenes in Korean and American Ginsengs (한국인삼과 북미산 서양상의 Sesquiterpene 성분 비교)

  • 위재준;신지영
    • Journal of Ginseng Research
    • /
    • v.21 no.3
    • /
    • pp.209-213
    • /
    • 1997
  • Sesquiterpenes of Korean ginseng (Panax ginseng C.A. Meyer, KG) and American ginseng (Panax quinquefolium, AG) were Isolated by simultaneous distillation and extraction (SDE) with 30% methanol and n-hexane or adsorption using C18 Sep-Pak . The sesquiterpenes in KG and AG were compared each other by using TLC and GC/MS. Thin layer chromatogram of KG gave 4~5 spots of terpenes colored by vanillin-sulfuric acid, while AG did one major spot. Total ion chromatogram of KG showed about 30 peaks of sesquiterpene having molecular weight 204. Among these, 9 components such as alloaromadendrene, germacrene B, isocaryophyllene, $\alpha$-neoclovene, ${\gamma}$-muurolene and $\beta$-panasinsene together occupied 81.5% of total sesquiterpenes identified. In AG, however, only 3 components, i.e., isocaryophyllene, $\beta$-bisabolene, $\beta$-sesquiphellandrene occupied 79.3% of total sesquiterpenes identified. Especially isocaryophyllene was a dominant component of AG occupying 56.6%. Eight sesquiterpenes, including alloaromadendrene, germacrene B and $\alpha$-humulene, were not detected in AG. These results indicate that sesquiterpenes could be used as indices for the chemical difference between KG and AG.

  • PDF