• Title/Summary/Keyword: Sensory system

Search Result 811, Processing Time 0.03 seconds

Laser Speckle Contrast Imaging for Measuring Cerebral Blood Flow Changes Caused by Electrical Sensory Stimulation

  • Cho, Ahra;Yeon, Chanmi;Kim, Donghyeon;Chung, Euiheon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.88-93
    • /
    • 2016
  • Recently laser speckle contrast (LSC) imaging has become a widely used optical method for in vivo assessment of blood flow in the animal brain. LSC imaging is useful for monitoring brain hemodynamics with relatively high spatio-temporal resolution. A speckle contrast imaging system has been implemented with electrical sensory stimulation apparatus. LSC imaging is combined with optical intrinsic signal imaging in order to measure changes in cerebral blood flow as well as neural activity in response to electrical sensory stimulation applied to the hindlimb region of the mouse brain. We found that blood flow and oxygen consumption are correlated and both sides of hindlimb activation regions are symmetrically located. This apparatus could be used to monitor spatial or temporal responses of cerebral blood flow in animal disease models such as ischemic stroke or cortical spreading depression.

Optimization of the Reduced-Calorie Yellow Layer Cake Preparations (저열량 레이어 케익 제조 공정의 최적화)

  • Kim, Yang-Hwa;L.Kim, Hye-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • Fat and sugar reduced yellow layer cake system was developed with varied replacement level of 30%, 60%, and 90% for AD(amylodextrin) and 10%, 30%, and 50% for PD(polydextrose). Physicochemical and sensory characteristics were investigated and optimum replacement level was also decided using response surface methodology. Sample groups of PD10AD30 had significantly the lowest specific gravity and viscosity, indicating the stable batter system with high air incorporation. Sample groups with PD10AD90 showed the highest volume index and were not significantly different from those of the PD10AD30. Sensory results indicated that PD30AD30 were significantly the most springy and moist, and the least hard of all sample groups. Sample groups with PD10AD90 had the least adhesiveness value. To establish the optimum substitution level using RSM, the restriction level was set up as moistness over five point, hardness under five points, and adhesiveness under four points. The optimum substitution level was 20% for PD and 88% for AD.

DNA diagnostic testing in hereditary motor and sensory neuropathies (유전성 운동 및 감각 신경병의 DNA 진단 검사)

  • Choi, Byung-Ok
    • Journal of Genetic Medicine
    • /
    • v.4 no.2
    • /
    • pp.115-121
    • /
    • 2007
  • Hereditary motor and sensory neuropathy (HMSN; Charcot-Marie-Tooth disease, CMT) was first described by Charcot and Marie in France and, independently, by Tooth in England in 1886. HMSN is the most common form of inherited motor and sensory neuropathy, and is a genetically heterogeneous disorder of the peripheral nervous system. Using positional cloning methods, the chromosomal localization (locus) of more than 40 inherited peripheral neuropathies was found in the last 15 years. However, these genetic analyses also show that many entities do not show linkage to the known loci. This issue deals with a clinical survey of inherited peripheral neuropathies regarding diagnostic approaches based on the molecular findings.

  • PDF

XML Based Heterogeneous Sensory Data Management System (XML 기반의이기종 센서 데이터 관리 시스템)

  • Nawaz, Waqas;Fahim, Muhammad;Lee, Sung-Young;Lee, Young-Koo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06b
    • /
    • pp.305-306
    • /
    • 2011
  • The Wireless sensor networks (WSN) continuously generates large volumes of raw data which own natural heterogeneity. These networks are normally application specific with no sharing or reusability of sensor data among applications. In order for applications and services to be developed independently of particular network, sensor data need to be available in more standardized form. In this paper, we propose Architecture for Sensory data management. This Extensible Markup Language (XML) oriented architecture allows the sensor data to be understood and processed in a meaningful way by a variety of applications with different purposes. We developed a middle layer which performs transformation on raw sensory data to XML and vice versa.

Nature-Inspired high sensitivity tactile sensor technology (자연모사 고감도 촉각센서 기술)

  • Kim, Tae Wi;Lee, Eun Han;Kang, Daeshik
    • Vacuum Magazine
    • /
    • v.4 no.3
    • /
    • pp.6-11
    • /
    • 2017
  • The tactile sensor of the future robot is becoming a necessity as a sensory organ which can communicate with the person most directly. Recently, the Nature-inspired technology has provided a new direction for the development of these tactile sensors. Here, we review three different nature-inspired tactile sensory system; high sensitivity pressure sensor inspired by beetle wings, highly sensitive strain sensor inspired by the spider's sensory organs, Tactile sensor inspired by human fingertip. These nature-inspired tactile sensors are expected to provide a breakthrough that not only can sensitively measure the pressure, but also delicately recognize the softness and texture of the material just like human.

Review of Somato Sensory Evoke Potential Test (체성감각유발전위검사에 대한 고찰)

  • Kim Myung-Chul;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.64-74
    • /
    • 2002
  • The SSEP(SomatoSensory Evoke Potentials) test is a valid and repeatable technique which correlates with clinically assessed joint position & vibration sense, skin touch & pressure sense. Also SSEP study is a simple and quantitative test, and has been used to evaluate the sensoty system along the somatosensory pathway from peripheral sensory receptor to the cortex. The ascending pathway of SSEP has been know to be posterior column-lemniscal pathway, but not without controversy. There are two kind of test mathods : one of test is median nerve SSEP and other test is posterior tibial nerve SSEP. Recently, SSEP used to performed to evaluate the usefulness of dermatomal SSEP(D-SSEP) and segmental SSEP(5-SSEP) for the diagnosis of lumbasacral radiculopathy, and it can be measure of ingual ahd palatine evoked potentials & indicator of medullary function useful for the diagnosis of brain death.

  • PDF

Self-adjusting Motion Generation Based on Sensory Feedback System (Sensory 피드백 시스템을 활용한 자율 적응 모션 생성)

  • Kwon, J.S.;Yang, W.; Park, G.T.;You, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1789-1790
    • /
    • 2007
  • 이 논문에서 우리는 생체모방 시스템을 구현하기 위해 일반적인 기계 시스템과 인간의 신경 진동자 모델을 결합하였다. 이러한 시스템은 외부환경의 변화에 따른 효과적인 자율 적응 운동 형태를 생성할 수 있다. 인간 및 동물의 주기적 자율 운동을 관장하는 Central Pattern Generator (CPG)는 신경 진동자 네트웍에 의해서 표현가능하고 이는 신경 진동자 모델 내부의 sensory 피드백 신호를 통해, 주기성을 같은 외란에 상호 작용하여 적절한 운동을 생성해 낸다. 따라서 이를 기계 시스템에 결합하면 이러한 시스템은 변화되는 환경이나 잘 알지 못하는 외란에 대하여 자율적으로 적응된 운동을 보일 수 있다. 이를 위해 본 논문은 이러한 신경 진동자 모델과 결합된 realtime 시스템을 구현하고 그 자율 적응 운동의 생성 가능성을 살펴본다.

  • PDF

Approach to food taste with meta food physics (식품의 맛에 대한 초식품물리학적 해석)

  • Chun, Jae Kun
    • Food Science and Industry
    • /
    • v.51 no.1
    • /
    • pp.61-71
    • /
    • 2018
  • The evaluation of food taste is one of the important activities of human consciousness and it is practiced by sensory analysis using 5 terminal sensorial consciousness among many other functions. These consciousness activities may be conducted by 3 way branching transformation (3-WBT) logic, which choose one out of 3 options under the multi-layered consciousness decision making system. On the basis of this logic, cognitive sensory evaluation (CSE) method was developed to carry out questionnaire survey covering objective and subjective issues during consumption of food for pregnant women. The results of the CSE for several food items was presented with the Table-pattern called CSET covering consciousness factors and their effects on the food consumers.

Improvement of Equilibrium Sensory of the Elderly Using A Virtual Bicycle Training System

  • Jeong, Sung-Hwan;Piao, Yong-Jun;Chong, Woo-Suk;Kim, Young-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2464-2467
    • /
    • 2005
  • The purpose of this study was to explore the effectives of a virtual bicycle system in improving the ability of equilibrium sense of normal healthy adults. Experiments were performed to find the factors related to the training of equilibrium sense. The subjects consisted of young and elderly people and the group of young people was compared against the group of elderly people. We investigated three different running modes of virtual bicycle system with two successive sets in total. W measured the parameters related to the running time, the velocity, the weight movement, the degree of the deviation from the road, and the location of the center of pressure (COP). The results showed that the running capability of the elderly became much better after repeated training. In addition, it was found out that the ability to control postural balance and the capability of equilibrium sensory were improved with the presentation of the visual feedback information of the distribution of weight. We also found that the running time and the running velocity reduced when there was no visual feedback information. From the results, our newly developed bicycle system seems to be effective in the diagnosis of equilibrium sense as well as in the improvement of the sense of sight, and vestibular function of the elderly in the field of rehabilitation training.

  • PDF

The Measurement of the Magnitude of Sensory Perception and Displeasure to the Vibration Stimuli applied on Forearm in upper Limb Amputees (진동자극에 대한 상지 절단자의 전완부 감각 인지 크기와 불쾌감 측정)

  • Kim, Sol-Bi;Chang, Yun-Hee;Kim, Shin-Ki;Kim, Gyoo-Suk;Mun, Mu-Sung;Bae, Tae-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.705-710
    • /
    • 2012
  • Research involving discomfort or pain related to haptic vibratory stimulation the for prosthesis users of myoelectrical hand is very lacking. Our objective of this study was to evaluate the displeasure and sensitivity of areas in forearm using vibration stimulation system between upper limb amputees and non-amputees. Twenty transradial amputees and forty non-amputees (20 youth, 20 elderly) were involved. We set up custom-made vibration stimulation system including eight actuators (4 medial parts and 4 lateral parts) and GUI-based acquisition system, to investigate changes of residual somatosensory sensibility and displeasure at proximal 25% of forearm. Eight vibration actuators were attached to the circumference of proximal 25% point of forearm at regular intervals. Sensitivity tests were used to stimulate the 120Hz and discomfort experiment was used to 37 ~ 223Hz. The subjective responses were evaluated by 10 point scale. The results showed that both groups were similar in sensitive areas. Response at around of radius was most sensitive than other areas in all subjects. Elderly group do not appear discomfort of vibrotactile; however, youth group and amputee presented discomfort of vibrotactile. Prosthesis with a vibrotactile feedback system should be developed considering the sensitivity. Furthermore, Future studies should investigate the scope of application of that principle.