• Title/Summary/Keyword: Sensor calibration

Search Result 730, Processing Time 0.038 seconds

Calibrating Capacitance Sensor for Determining Water Content of Volcanic-Ash Soils (화산회토양의 수분함량측정을 위한 Capacitance Soil Moisture Sensor의 Calibration)

  • Moon, Kyung-Hwan;Joa, Jae-Ho;Choi, Kyung-San;Seo, Hyoeng-Ho;Lim, Han-Cheol;Hyun, Hae-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.331-336
    • /
    • 2011
  • Capacitance soil moisture sensor is extensively used by soil research and irrigation management with its convenience and accuracy. This experiment was conducted to evaluate the acceptability of capacitance soil moisture sensor, named EnviroSCAN made by Sentek Ltd., in Jeju Island where volcanic ash soils are widely distributed, and to calibrate it to various soils with different amount of soil organic matter. For sensor calibration equation of volcanic ash soils, a logarithm function is better than a typical power function of non-volcanic ash soils. So there are possibilities of under evaluated in soil water contents in very wet and very dry conditions by using typical power function with volcanic ash soil areas. We suggested practical coefficients of typical calibration equation for using capacitance sensor in volcanic ash soils, also suggested equations for estimation of them with soil organic matter contents. The measurement of soil water content with a capacitance sensor can be affected by some soil characteristics such as porosity, soil organic matter content, EC, etc. So those factors should be controlled for improving the accuracy of measurement.

Variable Temperature Cryostat for Cryogenic Temperature Sensor Calibration

  • Kim, Myung Su;Choi, Yeon Suk;Kim, Dong Lak
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.46-49
    • /
    • 2012
  • The selection of the temperature sensor in the cryogenic system depends on the temperature range, shape and accuracy. The accuracy of the temperature sensor is essential to improve the reliability of experiment. We have developed the variable temperature cryostat using a two-stage cryocooler. In order to reduce heat load, thermal shield is installed at the first stage with MLI (Multiple layer insulation). We have also developed the sensor holder calibrating more than twenty sensors at the same time for saving time and money. The system can calibrate sensor at variable temperature by controlling electric heater. In this paper, we present design and fabrication of variable temperature cryostat and representative result of Cernox sensor calibration.

Laboratory geometric calibration simulation analysis of push-broom satellite imaging sensor

  • Reza Sh., Hafshejani;Javad, Haghshenas
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.1
    • /
    • pp.67-82
    • /
    • 2023
  • Linear array imaging sensors are widely used in remote sensing satellites. The final products of an imaging sensor can only be used when they are geometrically, radiometrically, and spectrally calibrated. Therefore, at the first stages of sensor design, a detailed calibration procedure must be carefully planned based on the accuracy requirements. In this paper, focusing on inherent optical distortion, a step-by-step procedure for laboratory geometric calibration of a typical push-broom satellite imaging sensor is simulated. The basis of this work is the simulation of a laboratory procedure in which a linear imager mounted on a rotary table captures images of a pin-hole pattern at different angles. By these images and their corresponding pinhole approximation, the correction function is extracted and applied to the raw images to give the corrected ones. The simulation results illustrate that using this approach, the nonlinear effects of distortion can be minimized and therefore the accuracy of the geometric position of this method on the image screen can be improved to better than the order of sub-pixel. On the other hand, the analyses can be used to proper laboratory facility selection based on the imaging sensor specifications and the accuracy.

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

Development of the Calibration Algorithm of 3 Axis Vector Sensor Using Ellipsoid (타원체를 이용한 3축 센서의 실시간 보정 알고리듬 개발)

  • Hwang, Jung Moon;Kim, Jung Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.643-651
    • /
    • 2015
  • Multi-axis magnetic and accelerometer sensor are widely used in consumer product such as smart phones. The vector output of multi-axis sensors have errors on each axis such as offset error, scale error, non-orthogonality. These errors cause many problems on the performance of the applications. In this paper, we designed the effective inline compensation algorithm for calibrating of 3 axis sensors using ellipsoid for mass production of multi-axis sensors. The outputs with those kinds of errors can be modeled by ellipsoid, and the proposed algorithm makes sequential mappings of the virtual ellipsoid to perfect sphere which is calibrated function of the sensor on three-dimensional space. The proposed calibrating process composed of four main stages and is very straightforward and effective. In addition, another imperfection of the sensor such as the drift from temperature can be easily inserted in each mapping stage. Numerical simulation and experimental results shows great performance of the proposed compensation algorithm.

Camera Calibration when the Accuracies of Camera Model and Data Are Uncertain (카메라 모델과 데이터의 정확도가 불확실한 상황에서의 카메라 보정)

  • Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • Camera calibration is an important and fundamental procedure for the application of a vision sensor to 3D problems. Recently many camera calibration methods have been proposed particularly in the area of robot vision. However, the reliability of data used in calibration has been seldomly considered in spite of its importance. In addition, a camera model can not guarantee good results consistently in various conditions. This paper proposes methods to overcome such uncertainty problems of data and camera models as we often encounter them in practical camera calibration steps. By the use of the RANSAC (Random Sample Consensus) algorithm, few data having excessive magnitudes of errors are excluded. Artificial neural networks combined in a two-step structure are trained to compensate for the result by a calibration method of a particular model in a given condition. The proposed methods are useful because they can be employed additionally to most existing camera calibration techniques if needed. We applied them to a linear camera calibration method and could get improved results.

Development of Calibration Jet System for Calibrating a Flow Sensor (유동센서 보정용 캘리브레이션 제트 시스템 개발)

  • Chang, J.W.;Byun, Y.H.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.11 no.1
    • /
    • pp.41-55
    • /
    • 2003
  • A calibration jet system using separate blower is developed to calibrate a flow sensor effectively. Designed open circuit type mini calibration jet system, which has the dimension of $0.5m(W){\times}1.17m(H)$ is small compared with conventional calibration jet systems. The exit of nozzle has exchangeable contractions with a cross section area of $38.5cm^2$ , and a cross section area of $113.1cm^2$, respectively. The ranges of wind speed at exit of exchangeable nozzles are $7.5{\sim}42\;m/s$ and $1.8{\sim}16.5\;m/s$, respectively. The input power for the high pressure blower is 1.18kW. The turning vanes for corner was rolled flat plate parallel to the flow direction. The flow conditioning screen was located immediately downstream of the wide-angle diffuser. The honeycomb and two flow conditioning screens were located in the stagnation chamber. From the economical point of view and the simplicity of the calibration jet system set up and handling, it can be said that the developed calibration jet system is an effective calibration jet system. This system can also be used to calibrate the flow sensor with high resolution.

  • PDF

RADIOMETRIC CHARACTERISTICS OF KOMPSAT-2 HIGH RESOLUTION IMAGES

  • Chi, Jun-Hwa;Yoon, Jong-Suk;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.390-393
    • /
    • 2007
  • KOMPSAT-2, the first Korean high resolution earth observing satellite, continuously acquires high resolution images since July 2006. The quality of satellite images should be geometrically and radiometrically ensured before distribution to users. This study focused on absolute radiometric calibration which is a prerequisite procedure to ensure the radiometric quality of optical satellite images. In this study, we performed reflectance-based vicarious calibration methods on several uniform targets collected through several field campaigns in 2007. The radiative transfer model, MODTRAN, was used to estimate the amount of energy received at the sensor. The energy reached at the sensor are affected by several factors such as reflectance of targets, atmospheric condition, geometry condition between Sun and the sensor, etc. This study proposes the absolute radiometric calibration coefficients of KOMPSAT-2 MSC images combining several types of collected data through field works and tried to compare dynamic range of sensor-detected energy with other commercial high resolution sensors.

  • PDF

Estimation Technique of Fixed Sensor Errors for SDINS Calibration

  • Lee, Tae-Gyoo;Sung, Chang-Ky
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.4
    • /
    • pp.536-541
    • /
    • 2004
  • It is important to estimate and calibrate sensor errors in maintaining the performance level of SDINS. In this study, an estimation technique of fixed sensor errors for SDINS calibration is discussed. First, the fixed errors of gyros and accelerometers, excluding gyro biases are estimated by the navigation information of SDINS in multi-position. The SDINS with RLG includes flexure errors. In this study, the gyros flexures are out of consideration, but the proposed procedure selects certain positions and rotations in order to minimize the influence of flexures. Secondly, the influences of random walks, flexures and orientation errors are verified via numerical simulations. Thirdly, applying the previous estimated errors to SDINS, the estimation of gyro biases is conducted via the additional control signals of close-loop self-alignment. Lastly, the experiments illustrate that the extracted calibration parameters are available for the improvement of SDINS.

Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer (삼직교 열선유속계의 간편한 측정법 개발)

  • Kim, Jin-Kwon;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.