• Title/Summary/Keyword: Sensor arrays

Search Result 147, Processing Time 0.03 seconds

General Linearly Constrained Narrowband Adaptive Arrays in the Eigenvector Space

  • Chang, Byong Kun
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.3
    • /
    • pp.137-142
    • /
    • 2017
  • A general linearly constrained narrowband adaptive array is examined in the eigenvector space. The optimum weight vector in the eigenvector space is shown to have the same performance as in the standard coordinate system, except that the input signal correlation matrix and look direction steering vector are replaced with the eigenvalue matrix and transformed steering vector. It is observed that the variation in gain factor results in the variation in the distance between the constraint plane and the origin in the translated weight vector space such that the increase in gain factor decreased the distance from the constraint plane to the origin, thus affecting the nulling performance. Simulation results showed that the general linearly constrained adaptive array performed better at an optimal gain factor compared with the conventional linearly constrained adaptive array in a coherent signal environment and the former showed similar performance as the latter in a noncoherent signal environment.

Biological smart sensing strategies in weakly electric fish

  • Nelson, Mark E.
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.107-117
    • /
    • 2011
  • Biological sensory systems continuously monitor and analyze changes in real-world environments that are relevant to an animal's specific behavioral needs and goals. Understanding the sensory mechanisms and information processing principles that biological systems utilize for efficient sensory data acquisition may provide useful guidance for the design of smart-sensing systems in engineering applications. Weakly electric fish, which use self-generated electrical energy to actively sense their environment, provide an excellent model system for studying biological principles of sensory data acquisition. The electrosensory system enables these fish to hunt and navigate at night without the use of visual cues. To achieve reliable, real-time task performance, the electrosensory system implements a number of smart sensing strategies, including efficient stimulus encoding, multi-scale virtual sensor arrays, task-dependent filtering and online subtraction of sensory expectation.

Development of a smart wireless sensing unit using off-the-shelf FPGA hardware and programming products

  • Kapoor, Chetan;Graves-Abe, Troy L.;Pei, Jin-Song
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.69-88
    • /
    • 2007
  • In this study, Field-Programmable Gate Arrays (FPGAs) are investigated as a practical solution to the challenge of designing an optimal platform for implementing algorithms in a wireless sensing unit for structuralhealth monitoring. Inherent advantages, such as tremendous processing power, coupled with reconfigurable and flexible architecture render FPGAs a prime candidate for the processing core in an optimal wireless sensor unit, especially when handling Digital Signal Processing (DSP) and system identification algorithms. This paper presents an effort to create a proof-of-concept unit, wherein an off-the-shelf FPGA development board, available at a price comparable to a microprocessor development board, was adopted. Data processing functions, including windowing, Fast Fourier Transform (FFT), and peak detection, were implemented in the FPGA using a Matlab Simulink-based high-level abstraction tool rather than hardware descriptive language. Simulations and laboratory tests were carried out to validate the design.

Nanowell Array based Sensor and Its Packaging

  • Lee, JuKyung;Akira, Tsuda;Jeong, Myung Yung;Lee, Hea Yeon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • This article reviews the recent progress in nanowell array biosensors that use the label-free detection protocol, and are detected in their natural forms. These nanowell array biosensors are fabricated by nanofabrication technologies that should be useful for developing highly sensitive and selective also reproducible biosensors. Moreover, electrochemical method was selected as analysis method that has high sensitivity compared with other analysis. Finally, highly sensitive nanobiosensor was achieved by combining nanofabrication technologies and classical electrochemical method. Many examples are mentioned about the sensing performance of nanowell array biosensors will be evaluated in terms of sensitivity and detection limit compared with other micro-sized electrode without nanowell array.

Synthesis of Optimum Broadband Null in Randomly Perturbed Linear Arrays (무작위 오류가 있는 선형 어레이의 최적 광대역 영점 형성)

  • 장병건
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.105-113
    • /
    • 1995
  • If broadband interference signals are incident at an array of sensor/antenna elements, it is desirable to form a set of bnoadband nulls around the directions of the interference signals to improve the array performance. An efficient way of generating a broadband null is to synthesize a derivative null. The performance of a derivative null in a constrained linear array which is subjected to random variations with respect to array weight and element Position is discussed. Computer simulation results are presented.

  • PDF

Frequency Response Compensation Technique for Capacitive Microresonator (용량형 마이크로 공진기의 주파수 응답 보상 기법)

  • Seo, Jin-Deok;Lim, Kyo-Muk;Ko, Hyoung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.235-239
    • /
    • 2012
  • This paper presents frequency response compensation technique, and a self-oscillation circuit for capacitive microresonator with the compensation technique using programmable capacitor array, to compensate for the frequency response distorted by parasitic capacitances, and to obtain stable oscillation condition. The parasitic capacitances between the actuation input port and capacitive output port distort the frequency response of the microresonator. The distorted non-ideal frequency response can be compensated using two programmable capacitor arrays, which are connected between anti-phased actuation input port and capacitive output port. The simulation model includes the whole microresonator system, which consists of mechanical structure, transimpedance amplifier with automatic gain control, actuation driver and compensation circuit. The compensation operation and oscillation output of the system is verified with the simulation results.

Association Algorithm for the Distributed Passive Linear Arrays and the Radar (분산 선배열 소나와 레이다를 이용한 표적 연관 기법)

  • Kim Jin-Seok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.1 s.20
    • /
    • pp.25-31
    • /
    • 2005
  • PLA(Passive Linear Array) system has been primarily utilized to detect and track underwater targets, such as submarines. This system has difficulty in distinguishing between underwater targets and surface ships in a dense target environment. And a single-PLA system does not provide target state observability. At least two PLAs are necessary to observe a track uniquely. To classify and localize the underwater targets effectively, first of all, it is very of importance to discriminate the surface ships in the multi-target environment. These problems can be overcome by the association of distributed PLAs and radars. In this paper, we present an algorithm to solve the track-to-track association of the heterogeneous data from three PLAs and one radar are noncollocated with known sensor positions. Also, this paper shows the simulation results to verify the proposed algorithm.

SDP-Based Adaptive Beamforming with a Direction Range (방향범위를 이용한 SDP 기반 적응 빔 형성)

  • Choi, Yang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.519-527
    • /
    • 2014
  • Adaptive arrays can minimize contributions from interferences incident onto an sensor array while preserving a signal the direction vector of which corresponds to the array steering vector to within a scalar factor. If there exist errors in the steering vector, severe performance degradation can be caused since the desired signal is misunderstood as an interference by the array. This paper presents an adaptive beamforming method which is robust against steering vector errors, exploiting a range of the desired signal direction. In the presented method, an correlation matrix of array response vectors is obtained through integration over the direction range and a minimization problem is formulated using some eigenvectors of the correlation matrix such that a more accurate steering vector than initially given one can be found. The minimization problem is transformed into a relaxed SDP (semidefinite program) problem, which can be effectively solved since it is a sort of convex optimization. Simulation results show that the proposed method outperforms existing ones such as ORM (outside-range-based method) and USM (uncertainty-based method).

Geophysical Study Through Infrasound Observation (인프라사운드 관측을 통한 지구물리학적 연구)

  • Che, Il-Young;Jeon, Jeong-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.495-505
    • /
    • 2006
  • Atmospheric infrasound is defined as low frequency inaudible sound waves generated from natural phenomena and human activities. One property of long-distance travelling of infrasound makes it possible to detect the wave propagated from remote sound sources and to understand many geophysical phenomena generating it. Recently, advanced global infrasound sensor arrays are being deployed to monitor the clandestine nuclear test and to study geophysical phenomena in the world. In Korea, five seismo-acoustic arrays consisting of co-located seismometer and micro-barometer have been operated to discriminate the artificial explosions from the natural earthquakes in and around the Korean Peninsula. In addition to the discrimination purpose, these ways also record distinct infrasonic signals from natural phenomena on global scale such as large earthquake, bolide event, volcanic explosion, typhoon, and so on. As a new frontier in monitoring the earth, infrasound is being applied to understand various phenomena in and above the earth's surface.

A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia (전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구)

  • Park, Mun-Kyu;Noh, Si-Cheol;Park, Jae-Hyun;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.