Browse > Article
http://dx.doi.org/10.6117/kmeps.2014.21.3.019

Nanowell Array based Sensor and Its Packaging  

Lee, JuKyung (Department of Mechanical and Industrial Engineering, College of Engineering, Northeastern University)
Akira, Tsuda (Department of Environmental Health, Harvard School of Public Health)
Jeong, Myung Yung (Department of Congo-Mechatronics Engineering, Pusan National University)
Lee, Hea Yeon (Department of Mechanical and Industrial Engineering, College of Engineering, Northeastern University)
Publication Information
Journal of the Microelectronics and Packaging Society / v.21, no.3, 2014 , pp. 19-24 More about this Journal
Abstract
This article reviews the recent progress in nanowell array biosensors that use the label-free detection protocol, and are detected in their natural forms. These nanowell array biosensors are fabricated by nanofabrication technologies that should be useful for developing highly sensitive and selective also reproducible biosensors. Moreover, electrochemical method was selected as analysis method that has high sensitivity compared with other analysis. Finally, highly sensitive nanobiosensor was achieved by combining nanofabrication technologies and classical electrochemical method. Many examples are mentioned about the sensing performance of nanowell array biosensors will be evaluated in terms of sensitivity and detection limit compared with other micro-sized electrode without nanowell array.
Keywords
Nanowell Arrays (NWA); Nanobiosensor; Electrochemical (EC) method; Chip-packaging;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. M. Kim, H. S. Jung, J. W. Park, H. Oka, T. Yukimasa, H. Y. Lee and T. Kawai, "Spontaneous Immobilization of Liposomes on Electron Beam Technique", J. Am. Chem. Soc., 127(7), 2358 (2005).   DOI   ScienceOn
2 H. S. Jung, J. M. Kim, J. W. Park, H. Y. Lee and T. Kawai. "Amperometric immunosensor for direct detection based upon functional lipid vesicles immobilized on nanowell array electrode", Langmuir : the ACS journal of surfaces and colloids., 21(13), 6025 (2005).   DOI
3 J. L. Wilbur, E. Kim and Y. Xia. "Whitesides GM. Lithographic molding: A convenient route to structures with submicrometer dimensions**", Advanced Materials., 7(7), 649 (1995).   DOI
4 P. Kim, B. K. Lee, H. Y. Lee, T. Kawai and K. Y. Suh. "Molded Nanowell Electrodes for Site-Selective Single Liposome Arrays", Advanced Materials., 20(1), 31 (2008).   DOI
5 J. Lee, S. Cho, H. Ryu, J. Park, S. Lim, B. Oh, C. Lee, W. Huang, A. Busnaina and H. Lee. "Wafer-scale nanowell array patterning based electrochemical impedimetric immunosensor", Journal of biotechnology., 168(4), 584 (2013).   DOI
6 B. K. Lee, N. G. Choa, H. Tanaka, N. Y. Hong, D. P. Kim, H. Y. Lee, T. Kawai. "Photocurable Polyhedral Oligomeric Silsequioxane-based Resists for Nanoimprint Lithography: Fabrication of High-aspect Ratio Structures and Replica Molds", Langmuir : the ACS journal of surfaces and colloids., 26(18), 14915 (2010).   DOI
7 D. C. Ng, T. Nakagawa, T. Mizuno, T. Tokuda, M. Nunoshita, H. Tamura, Y. Ishikawa, S. Shiosaka and J. Ohta. "Integrated in vivo neural imaging and interface CMOS devices: design, packaging, and implementation" Sensors Journal, IEEE., 8(1), 121 (2008).   DOI