• Title/Summary/Keyword: Sensitive analysis

Search Result 3,634, Processing Time 0.032 seconds

A Stuyd on the Load-sensitive Hydraulic Pump Control System (부하 감응형 유압 펌프 제어 시스템에 관한 연구)

  • 송창섭;이용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.585-588
    • /
    • 1995
  • In this study, the analysis of the static and dynamic characteristics of the load-sensitive hydraulic pump control system used in the hydraulic excavator was performed by hydraulic circuit ananlysis program. Thess results was verified by the experimental data of the hydraulic excavtor system. The responses on effective parameters of system at the controllable region and the pressure variation of the pump used in hydraulic excavator system was studied to enhance the static performace of the system. the parameter enhance dynamic sharacteristics was considerd.

  • PDF

Analysis of Adsorption Pattern of Orgnaic Gas Using Resonant Admittance Method (공진어드미턴스를 이용한 유기가스의 흡착패턴의 분석)

  • Kim, J.M.;Choi, Y.S.;Chang, J.S.;Kwon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1565-1568
    • /
    • 1996
  • The adsorption and desorption behavior of orgnaic gases were investigated using the resonant frequency and admittance method. Sensitive material were depositied on the quartz crystal microbalence by using Langmuir-Blodgett method. To investigate the response characteristics of organic gases, Resonant frequency-Resonant admittance (F-A) diagram was used. The quantity and quality information about organic gases can be obtained by that diagram. As a results, when the organic gases were adsorpted into sensitive material, the physical property changees of sensitive material were occured.

  • PDF

Cold Chain Management in Pharmaceutical Industry: Logistics Perspective

  • Yoon, Yuri
    • Journal of Distribution Science
    • /
    • v.12 no.5
    • /
    • pp.33-40
    • /
    • 2014
  • Purpose - This paper aims to review cold chain management, especially in the pharmaceutical industry, to explore the cold chain process of delivering temperature-sensitive pharmaceutical products, and to identify areas for further development. Research design, data, and methodology - The paper, based on literature review and corporate analysis, reviews the development and status of the cold supply chain system, including its important role in the pharmaceutical industry. Results - Logistics in this field requires more stages than are typically needed. Due to the unique characteristics of the market, few companies can provide the services; currently, only few global companies with large networks and high technologies can afford to do so. Expanding pharmaceutical markets to meet global demand will require cold chain development, especially in "pharmerging" markets. Conclusions - Cold chain is a highly sensitive market in terms of products being carried within the chain that itself is a complex system. However, at the same time, it is a niche market with new opportunities. Hence, a sound cold chain infrastructure is needed to satisfy companies, governments, and customers for both commercial and public reasons.

Analysis of Response Characteristics for Organic Gas of Polymeric Sensitive Films by Using Q. C. M. (수정진동자에 의한 감응성막의 유기가스 응답특성 분석)

  • 김경철;김정명;장상목;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.409-412
    • /
    • 1996
  • In this paper, the response characteristics of organic gases were investigated by using quartz crystal microbalance(Q.C.M) with different polymeric sensitive materials. The new linear parameter was discussed in order to develope gas sensing system using neural network and pattern recognition. We analyzed the response characteristics by the area of resonant frequency shift of quartz crystal, which mean affinities of organic gases for polymeric sensitive firm. The experimental results shows that the parameter made by the area of frequency shift which was linear with injection amount of organic gases has possibility to be used for pattern recognition and neural network. And they have different normalized pattern.

  • PDF

3D Nano Object Recognition based on Phase Measurement Technique

  • Kim, Dae-Suk;Baek, Byung-Joon;Kim, Young-Dong;Javidi, Bahram
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.108-112
    • /
    • 2007
  • Spectroscopic ellipsometry (SE) has become an important tool in scatterometry based nano-structure 3D profiling. In this paper, we propose a novel 3D nano object recognition method by use of phase sensitive scatterometry. We claims that only phase sensitive scatterometry can provide a reasonable 3D nano-object recognition capability since phase data gives much higher sensitive 3D information than amplitude data. To show the validity of this approach, first we generate various $0^{th}$ order SE spectrum data ($\psi$ and ${\Delta}$) which can be calculated through rigorous coupled-wave analysis (RCWA) algorithm and then we calculate correlation values between a reference spectrum and an object spectrum which is varied for several different object 3D shape.

Sensitivity Analysis of Strain on Notches under Cyclic Loading to 2-D Finite Element Density in Elasto-Plastic Finite Element Analysis (탄소성 유한요소해석시 2차원 유한요소 밀도에 대한 반복하중이 작용하는 노치부의 변형률의 민감도 분석)

  • Jong-Sung Kim;Hyun-Su Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • This paper presents sensitivity analysis results of strain on notches under cycling loading to 2-D finite element density considering plasticity. Cylindrical notched specimens having some stress concentrations were modeled with 2-D axisymmetrical finite element having various finite element densities. Elasto-plastic finite element analysis was performed for the various finite element models subjected to cycling loading considering plasticity. The finite element analysis results were compared to investigate sensitivity of the finite element analysis variables such as von-Mises effective stress, accumulated equivalent plastic strain, and equivalent plastic strain to 2-D finite element density. As a result of the comparison, it was found that the accumulated equivalent plastic strain is more sensitive than the others whereas the von-Mises effective stress is much less sensitive.

Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence (온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정)

  • Jung Woonseop;Kim Sungwook;Kim Ho-Young;Yoo Jung Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

A Study on the Susceptibility of Single-phase Sensitive Loads and the Three-phase Induction Motor by Voltage Sag (순간전압강하에 의한 단상 민감부하 및 삼상 유도전동기의 외란 민감도에 관한 연구)

  • Yun Sang-Yun;Moon Jong-Fil;Kim Jae-Chul;Lee Hee-Tae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • In this paper we explore the susceptibility of common sensitive loads by voltage sags of power distribution systems. The experimental approach was used for obtaining the susceptibility of single-phase loads and the three-phase induction motor. The experimental result of single-phase loads was transformed to the ITIC(Information of Technology Industry Council) format and used for evaluating the adverse impacts of a individual and repetitive sags using the performance contour of the foreign standard data. In order to assess the impact of voltage sags on three-phase induction motor, also, the experiment was peformed. The experiment was focused on the current, torque, and speed loss of the motor during a voltage sag. For comparing the impacts of individual and repetitive voltage sags, the variations of motor torque is focused among the experimental results. The sensitive curves of instantaneous current peak are used to describe the susceptibility of three-phase induction motor and 진so it were used for the quantitative analysis of the impact of three-phase induction motor due to voltage sags. Through the results of experiment, we verified that some types loads have more severe impact at repetitive voltage sags than individual ones and proposed method can be effectively used to evaluate the actual impact of voltage sags.

Preparation and Characterization of pH-Sensitive Poly(ethylene oxide) Grafted Methacrylic Acid and Acrylic Acid Hydrogels by ${\gamma}-ray $ Irradiation

  • Lim, Youn-Mook;Lee, Young-Moo;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.13 no.4
    • /
    • pp.327-333
    • /
    • 2005
  • pH-sensitive hydrogels were studied as a drug carrier for the protection of insulin from the acidic environment of the stomach before releasing it in the small intestine. In this study, hydrogels based on poly(ethylene oxide) (PEO) networks grafted with methacrylic acid (MAA) or acrylic acid (AAc) were prepared via a two-step process. PEO hydrogels were prepared by ${\gamma}-ray $ irradiation (radiation dose: 50 kGy, dose rate: 7.66 kGy/h), grafted by either MAA or AAc monomers onto the PEO hydrogels and finally underwent irradiation (radiation dose: 520 kGy, dose rate: 2.15 kGy/h). These grafted hydrogels showed a pH-sensitive swelling behavior. The grafted hydrogels were used as a carrier for the drug delivery systems for the controlled release of insulin. Drug-loaded hydrogels were placed in simulated gastric fluid (SGF, pH 1.2) for 2 hr and then in simulated intestinal fluid (SIF, pH 6.8). The in vitro drug release behaviors of these hydrogels were examined by quantification analysis with a UV-Vis spectrophotometer.

Psychological analysis of dental orthodontic patients using SCL-90-R (간이정신진단검사를 이용한 치과교정환자의 심리분석)

  • Ko, Hyo-Jin;Lee, So-Young;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2012
  • Objectives : This research was investigated to evaluate the psychological characteristics and changes of psychological state among dental orthodontic patients. Methods : This cross-sectional questionnaire research was conducted with 230 dental orthodontic patients in Busan from December 23, 2009 to March 6, 2010. The psychological analysis of dental orthodontic treatment patients was performed with Symptom checklist-90-revision(SCL-90-R) considering 5 general characteristics and 2 treatment period related characteristics. Estimated psychological results were changed T-score. Data analysis was performed with descriptive analysis, t-test and ANOVA using SAS(ver 9.1) program. Results : The levels of T-score of SCL-90-R were $43.88{\pm}7.50$ in hostility(HOS), $43.38{\pm}4.64$ in phobic anxiety(PHOB), $43.20{\pm}6.24$ in somatization(SOM), $42.13{\pm}6.71$ in paranoid ideation(PAR), $41.39{\pm}8.16$ in interpersonal sensitive(I-S), $41.01{\pm}7.90$ in obsessive-compulsive(O-C), $40.96{\pm}5.37$ in psychoticism(PSY), $40.96{\pm}5.19$ in anxiety(ANX) and $39.81{\pm}6.80$ in depression(DEP), respectively. The T-score of phobic anxiety in before treatment group was higher than that of treatment groups. The T-score of interpersonal sensitive and paranoid ideation in over 36 months treatment period group were higher than that of other treatment period groups. Conclusions : Phobic anxiety(PHOB), interpersonal sensitive(I-S) and paranoid ideation(PAR) were affected in pre-treatment and long-term treatment dental orthodontic patients. Psychological management methods considering treatment period are needed to improve mental health of dental orthodontic patients.