• 제목/요약/키워드: Self-etching primer

검색결과 61건 처리시간 0.027초

The effect of casein phosphopeptide amorphous calcium phosphate on the in vitro shear bond strength of orthodontic brackets

  • Park, Sun-Youn;Cha, Jung-Yul;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제43권1호
    • /
    • pp.23-28
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) on the shear bond strength (SBS) of brackets bonded to non-demineralized teeth with either phosphoric acid etching or self-etching primer. Methods: Sixty human premolars were randomly assigned to 1 of 4 treatment groups (n = 15 each): phosphoric acid etching (group 1); self-etching primer (group 2); CPP-ACP for 2 weeks + phosphoric acid etching (group 3), and CPP-ACP for 2 weeks + self-etching primer (group 4). After bonding of the maxillary premolar metal brackets, specimens were subjected to shear forces in a testing machine. Scanning electron microscopy was used to observe etching patterns on the enamel surfaces of all teeth. A 2-way analysis of variance was used to test for effects of CPP-ACP and etching system on SBS. Results: Significantly higher mean SBSs were observed in groups subjected to phosphoric acid etching (i.e., groups 1 and 3; p < 0.05). On the other hand, SBSs did not appear to be influenced by CPP-ACP (i.e., groups 3 and 4; p > 0.05). We observed a uniform and clear etched pattern on the enamel surface of the phosphoric acid etching groups. Conclusions: CPP-ACP does not significantly affect the SBS of orthodontic brackets bonded to non-demineralized teeth, regardless of which adhesive method is used to bond the brackets.

Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향 (The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive)

  • 김유신;이형순;이현정;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제34권5호
    • /
    • pp.439-447
    • /
    • 2004
  • 이 연구는 self-etching primer와 adhesive를 사용하여 법랑질 표면에 교정용 브라켓을 접착할 때 수분과 타액, 그리고 혈액에 의한 오염이 브라켓의 전단결합강도에 어떤 영향을 미치는지 알아보고자 시행되었다. 96개의 발거된 치아를 4개의 군으로 나누어서 self-etching primer와 adhesive를 사용하여 다음의 4가지 방법에 따라 교정용 브라켓을 접착하였다 첫 번째 군은 치면을 건조시킨 상태에서 부착하였고 두 번째, 세 번째, 네 번째 군은 각각 증류수, 인공타액. 혈액을 적용한 후 브라켓을 접착하였다 각 시편의 전단결합강도를 측정하였고 debonding 후에 브라켓과 치아 표면은 stereomicroscope을 사용하여 관찰하였다. 각 군에서 4개씩의 시편을 선택하여 표면처리된 법랑질 표면과 접착계면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 건조군과 증류수군의 전단결합강도는 각각 $15.22{\pm}2.86$ MPa과 $160.20{\pm}3.85MPa$로 혈액군의 전단결합강도$(12.50{\pm}2.94MPa)$보다 높았다.(P<0.05). 건조군과 증류수군, 그리고 인공타액군간에는 전단결합강도에 통계적 차이가 없었다(p>0.05). 혈액군은 다른군에 비해서 debonding 후 법랑질 표면에 잔류한 레진의 양이 더 적었다.(p<0.06). self-etching primer로 처리된 치면의 주사전자현미경 소견에서 건조군과 증류수군의 치면에서는 인공타액군과 혈액군에 비해서 더욱 뚜렷한 산부식 구조를 볼 수 있었다. 이상의 결과로서 self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 수분이나 타액의 오염은 결합력에 거의 영향을 미치지 않음을 알 수 있으며. 혈액으로 오염시에는 결합력에 영향을 미치지만. 임상적으로 유용한 최소 결합강도(5.9-7.8 MPa) 이상을 보이고 있음을 알 수 있었다.

Moisture Insensitive Primer와 Self-Etching Primer를 사용한 교정용 브라켓 접착 시 타액오염이 전단결합강도에 미치는 영향 비교 (Effects of Saliva Contamination on Shear Bond Strength with Conventional, Moisture Insensitive, and Self-Etching Primers)

  • 오윤정;오소희
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.21-28
    • /
    • 2019
  • 이 연구의 목적은 브라켓 부착 시 Conventional primer (CP), Moisture insensitive primer (MIP), Self-etching primer (SEP)을 사용하였을 때의 전단결합강도를 비교하고, 타액 오염 여부와 타액 오염의 시기가 전단결합강도에 미치는 영향을 평가하는 것이다. 총 135개의 소의 하악 절치가 연구에 사용되었다. 시편은 I, II, III 3개의 군으로 나누어 CP, MIP, SEP를 사용하여 브라켓을 부착하였다. 각 군은 3개의 하위군으로 나누어져서 타액 오염이 없는 군, 타액 오염 후 프라이머를 도포한 군, 프라이머 도포 후 타액 오염이 있는 군으로 설정하고 전단결합강도를 측정하였다. 연구 결과, 건조한 환경에서 전단결합강도는 CP, MIP, SEP의 순서로 높게 나타났다. CP는 타액 오염이 있는 경우에는 유의한 전단결합강도의 저하를 보였다. MIP, SEP를 사용한 경우에는 프라이머 도포 전 후 타액 오염이 있는 경우에 약간의 전단결합강도의 저하를 보였지만, 건조한 환경에서와 비교하여 유의한 차이는 보이지 않았다. 따라서 브라켓 접착 시 타액의 격리가 힘든 상황에서는 MIP 또는 SEP의 사용이 브라켓 전단결합강도의 저하를 방지하기 위하여 유용할 것으로 보인다.

자가 산부식 프라이머 시스템 사용시 인산에 의한 부가적인 산부식이 미세누출에 미치는 영향 (THE EFFECT OF ADDITIONAL ENAMEL ETCHING ON MICROLEAKAGE OF THE ADHESION OF SELF-ETCHING PRIMER SYSTEM)

  • 윤정진;민경산;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.363-368
    • /
    • 2003
  • The purpose of this study is to evaluate the effect of additional enamel etching with phosphoric acid on the microleakage of the adhesion of self-etching primer system. Class V cavity($4mm{\times}3mm{\times}1.5mm$) preparations with all margins in enamel were prepared on buccal surface of 42 extracted human upper central incisor teeth. Prepared teeth were randomly divided into 3 groups. Group 1:no additional pretreatment with 37% phosphoric acid (NE). Group 2:additional pretreatment with 37% phosphoric acid for 10 seconds (E10s). Group 3:additional pretreatment with 37% phosphoric acid for 20 seconds (E20s). The adhesives(Clearfil SE $Bond^{\circledR}$, Kuraray, Osaka, Japan) and composite resins(Clearfil $AP-X^{\circledR}$, Osaka, Kuraray, Japan) were applied following the manufacturer's instructions. All the specimens were finished with the polishing disc(3M dental product, St Paul, MN, USA), thermocycled for 500 cycles between $5^{\circ}C$ and $55^{\circ}C$ and resected apical 3-mm root. 0.028 stainless steel wire was inserted apically into the pulp chamber of each tooth and sealed into position with sticky wax. Surrounding tooth surface was covered with a nail varnish 2 times except areas 1mm far from all the margins. After drying for one day, soaked the samples in the distilled water. Microleakage was assessed by electrochemical method(System 6514, $Electrometer^{\circledR}$), Keithley, USA) in the distilled water. In this study, the microleakage was the lowest in group 1 (NE) and the highest in group 3(E20s)(NE

제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가 (A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES)

  • 김형수;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

자가 산부식 프라이머의 세포독성에 관한 실험적 연구 (In vitro cytotoxicity of self-etching primers)

  • 이창훈;김인령;김규천;김성식;손우성
    • 대한치과교정학회지
    • /
    • 제36권6호
    • /
    • pp.422-433
    • /
    • 2006
  • 자가 산부식 프라이머는 세포독성이 있는 것으로 알려져 있어 교정치료를 하는 동안 치주조직에 손상을 일으킬 수 있다. 본 연구의 목적은 자가 산부식 프라이머가 치주조직에 미치는 영향을 평가해 보고 이를 전통적인 접착법에 사용되는 프라이머와 비교하기 위하여 시행되었다. 시편은 임상에서 브라켓 접착 시 사용하는 Transbond XT Adhesive (3M Unitek, Monrovia, CA, USA)를 각각 Transbond XT Primer (3M Unitek, Monrovia, CA, USA), Clearfil SE bond (Kuraray, Osaka, Japan), Transbond Plus Self Etching Primer, Adper Prompt L-Pop (3M Unitek, Monrovia, CA, USA)과 혼합한 후 광중합하여 제작하였고, Transbond XT Adhesive를 중합한 대조군과 비교하였다. 이를 배양된 HGF-1 (Human eingiva Fibroblast), HaCaT (Human Keratinocyte cell line), RHEK (immorialized Human Epidermal Keratinocyte)에 노출시킨 후 세포의 형태 변화를 관찰하였고, MTT assay를 시행하여 세포독성을 비교, 평가하였다. 실험결과 72시간 후 HGF-1, HaCaT, RHEK를 이용한 실험에서 모든 프라이머의 세포독성이 높게 나타나 세포 돌기의 위축, 세포 형태의 변화, 세포 수의 감소, 세포의 괴사가 관찰되었다. MTT assay 실험 시 HGF-1 을 이용한 실험에서 Clearfil SE Bond, Transbond XT Primer, Transbond Plus SEP, Adper Prompt L-Pop의 순으로 세포독성이 높게 나타났고, HaCaT를 이용한 실험에서 Cleafil SE Bond, Adper Prompt L-Pop, Transbond Plus SEP, Transbond XT Primer 순으로 세포독성이 높게 나타났으며, RHEK를 이용한 실험에서 Clearfil SE Bond, Transbond XT Primer, Adper Prompt L-Pop, Transbond Plus SEP 순으로 세포독성이 높게 나타났다. 자가 산부식프라이머는 전통적으로 사용되는 프라이머와 마찬가지로 세포독성이 유의하게 높으므로 구강내 사용시 주의가 필요하다.

오염된 유치 상아질에 대한 자가 부식 프라이머의 결합강도에 관한 연구 (SHEAR BOND STRENGTH OF SELF-ETCHING PRIMER SYSTEMS TO CONTAMINATED DENTIN IN PRIMARY TEETH)

  • 서주희;이광희;김대업
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.107-114
    • /
    • 2002
  • 연구목적은 자가부식 프라이머의 적용 시기에 따른 타액과 혈액 오염에 대한 결합력에 미치는 영향을 알아보는 것이었다. 유치 시편을 각각 10개씩 제작하여 대조군, 접착전 타액 오염, 접착제 중합후 타액 오염, 접착전 혈액 오염, 접착제 중합후 혈액 오염된 상황으로 2가지 종류의 자가부식 접착제와 복합레진을 적용하여 만능 물성 시험기로 전단결합강도를 측정, 분석하였다. 접착제 적용전 타액 오염(I군)시에는 대조군과 비교하여 결합력이 유사하거나 약간 감소되었으나, 통계학적 유의한 차이가 없었다(P>0.05). 접착후 타액 오염(II군)이나 접착 전후의 혈액 오염(III, IV군)시 유의하게 결합력이 감소하였다. (P<0.01). Clearfil SE Bond가 AQ Bond보다 유의하게 높은 결합강도를 보였다(P<0.05).

  • PDF

접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향 (The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system)

  • 류원일;손원준;백승호;이인한;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.385-396
    • /
    • 2011
  • 연구목적: 본 연구는 치근벽의 전처리 개념과 접착제의 중합방법이 레진계 근관충전제의 치근단 밀폐능에 미치는 영향을 평가하였다. 연구 재료 및 방법: 3가지 다른 접착변수를 조합하여 충전한 Resilon-RealSeal 시스템의 근단미세누출을 색소침투법을 이용하여 통상의 가타퍼쳐 충전과 비교하였다. 실험군은 자가부식형 RealSeal primer와 이중중합형 RealSeal sealer를 이용하여 Resilon 충전한 SEDC군, 산부식없이 Scotchbond Multi-Purpose primer를 적용한 후 접착제는 광중합하고 Resilon을 충전한 NELC군, 및 Scotchbond Multi-Purpose의 접착강화제와 접착제를 total etch/wet bonding과 광중합의 술식을 정확하게 지켜서 Resilon을 충전한 TELC군으로 구분하였다. 대조군(GPCS)에서는 통상의 AH26 plus sealer를 사용하여 가타퍼쳐를 충전 하였다. 결과: 치아장축방향의 색소침투는 TELC군에서 GPCS군과 SEDC군에 비해 유의하게 작았다(Kruskal-Wallis test, p < 0.05). 횡단면의 미세누출 점수도 TELC군이 근첨으로부터 2 - 5 mm의 범위에서 다른 군에 비해 유의하게 낮았다(Kruskal-Wallis test, p < 0.05). 결론: 레진계 근관충전제를 사용 시에는, 자가부식형 전처리제와 이중중합형 sealer보다는, total etch/wet bonding 개념과 적절한 광중합을 도모하는 전처리제 및 접착제의 사용이 치근단 미세누출을 감소시키므로 추천된다.

자가 산부식 프라이머의 적용시간이 상아질의 미세인장 결합강도에 미치는 영향 (INFLUENCE OF APPICATION TIME OF SELF-ETCHING PRIMERS ON DENTINAL MICROTENSILE BOND STRENGTH)

  • 조영곤;이영곤;김종욱;박병철;김종진;최희영;진철희;유상훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.430-438
    • /
    • 2004
  • This study evaluated the influence of application time of self-etching primers on microtensile bond strength (${\mu}$TBS) to dentin using three self-etching primer adhesive systems. Dentin surfaces were exposed from forty-eight human molars. They were conditioned with three self-etching primers (Clearfil SE Bond [SE], Unifil Bond [UF], Tyrian SPE + One Step Plus [TY]) and different primining times (10s, 20s, 30s and 40s). Composite resins were bonded to dentin surfaces and specimens were made. ${\mu}TBS$ was tested and statistically compared using by one-way ANOVA and Tukey's Test. The results of this study presented that priming time for 10s in SE and UF groups and for 30s and 40s in TY group was highly decreased ${\mu}TBS$ to dentin.

치질에 접착된 자가 산부식 프라이머와 자가 산부식 접착제의 형태학적 양상 (MORPHOLOGICAL PATTERNS OF SELF-ETCHING PRIMERS AND SELF-ETCHING ADHESIVE BONDED TO TOOTH STRUCTURE)

  • 조영곤;이석종;정진호;이영곤;김수미
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.23-33
    • /
    • 2003
  • The purpose of this study was to compare in vitro interfacial relationship of restorations bonded with three self-etching primer adhesives and one self-etching adhesive. Class I cavity preparations were prepared on twenty extracted human molars. Prepared teeth were divided into four groups and restored with four adhesives and composites Clearfil SE $Bond/Clearfil^{TM}$ AP-X (SE), UniFil $Bond/UniFil^{\circledR}$ F (UF), FL $Bond/Filtek^{TM}$ Z 250 (FL) and Prompt $L-Pop/Filtek^{TM}$ Z 250 (LP) After storing in distilled water of room temperature for 24 hours, the specimens were vertically sectioned and decalcified. Morphological patterns between the enamel/dentin and adhesives were observed under SEM. The results of this study were as follows : 1. They showed close adaptation between enamel and SE, UF and FL except for LP. 2. The hybrid layer in dentin was $2{\;}\mu\textrm{m}$ thick in SE, $1.5{\;}\mu\textrm{m}$ thick in UF, and $0.4{\;}\mu\textrm{m}$ in both FL and LP. So, the hybrid layers of SE and UF were slightly thicker than that of FL and LP. 3. The lengths and diameters of resin tags in UF and FL were similar, but those of LP were slightly shorter and slenderer than those of SE. 4. The resin tags were long rod shape in SE, and funnel shape in other groups Within the limitations of this study, it was concluded that self-etching primer adhesives showed close adaptation on enamel. In addition, the thickness of hybrid layer ranged from $0.4-1.5{\;}\mu\textrm{m}$ between adhesives and dentin. The resin tags were long rod or funnel shape, and dimension of them was similar or different among adhesives.