INFLUENCE OF APPICATION TIME OF SELF-ETCHING PRIMERS ON DENTINAL MICROTENSILE BOND STRENGTH

자가 산부식 프라이머의 적용시간이 상아질의 미세인장 결합강도에 미치는 영향

  • Cho, Young-Gon (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Lee, Young-Gon (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Kim, Jong-Uk (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Park, Byung-Cheul (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Kim, Jong-Jin (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Choi, Hee-Young (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Jin, Cheul-Hee (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Yoo, Sang-Hoon (Department of Conservative Dentistry, College of Dentistry, Chosun University)
  • 조영곤 (조선대학교 치과대학 치과보존학교실) ;
  • 이영곤 (조선대학교 치과대학 치과보존학교실) ;
  • 김종욱 (조선대학교 치과대학 치과보존학교실) ;
  • 박병철 (조선대학교 치과대학 치과보존학교실) ;
  • 김종진 (조선대학교 치과대학 치과보존학교실) ;
  • 최희영 (조선대학교 치과대학 치과보존학교실) ;
  • 진철희 (조선대학교 치과대학 치과보존학교실) ;
  • 유상훈 (조선대학교 치과대학 치과보존학교실)
  • Published : 2004.09.01

Abstract

This study evaluated the influence of application time of self-etching primers on microtensile bond strength (${\mu}$TBS) to dentin using three self-etching primer adhesive systems. Dentin surfaces were exposed from forty-eight human molars. They were conditioned with three self-etching primers (Clearfil SE Bond [SE], Unifil Bond [UF], Tyrian SPE + One Step Plus [TY]) and different primining times (10s, 20s, 30s and 40s). Composite resins were bonded to dentin surfaces and specimens were made. ${\mu}TBS$ was tested and statistically compared using by one-way ANOVA and Tukey's Test. The results of this study presented that priming time for 10s in SE and UF groups and for 30s and 40s in TY group was highly decreased ${\mu}TBS$ to dentin.

Keywords

References

  1. Bouillaguet S, Gysi P, Wataha JC, Ciucchi B, Cattani M, Godin C, Meyer JM. Bond strength of composite to dentin using conventional. one-step, and self-etching adhesive systems. J Dent 29(1):55-61, 2001 https://doi.org/10.1016/S0300-5712(00)00049-X
  2. Inoue S, Meerbeek BV, Vargas M, Yoshida Y, Lambrechts P, Vanherle G. Adhesion mechanism of self-etching adhesives. Advanced Adhesive Dentistry 3rd International Kuraray symposium. p131-148, 1999
  3. Miyazaki M, Platt JA, Onose H, Moore BK. Influence of dentin primer application methods on dentin bond strength. Oper Dent 21:167-172, 1996
  4. Miyazaki M, Iwasaki K, Onose H, Moore BK. Enamel and dentin bond strengths of single application bonding systems. Am J Dent 14:361-366, 2001
  5. Frankenberger R, Perdigao J, Rosa BT, Lopes M. 'No-bottle' vs 'multi-bottle' dentin adhesive-a microtensile bond strength and morphological study. Dent Mater 17:373-380, 2001 https://doi.org/10.1016/S0109-5641(00)00084-1
  6. Hashimoto M, Ohno H, Kaga M, Sano H, Oguchi H, Arki Y, Kubota M. Over-etching effects on micro-tensile bond strength and failure patterns for two dentin bonding systems. J Dent 30:99-105, 2001
  7. Kazemi RB, Meiers JC, Peppers K. Effect of caries disclosing agents on bond strengths of total-etching and self-etching primer dentin bonding systems to resin composite. Oper Dent 27:238-242, 2002
  8. 조영곤. 조공철. 자가 산부식 프라이머와 자가 산부식 접착제의 변연 미세누출. 대한치과보존학회지 27(5):493-501, 2002
  9. 조영곤. 이석종. 정진호. 이영곤. 김수미. 치질에 접착된 자가 산부식 프라이머와 자가 산부식 접착제의 형태학적인 양상. 대한치과보존학회지 28(1):23-33, 2003
  10. Kubo S, Yokota H, Sata Y, Hayashi Y, Microleakage of self-etching primers after thermal and flexural load cycling. Am J Dent 14:163-169, 2001
  11. Perdigao J, Frankenberger R, Rosa RT. New trends in dentin/enamal adhesion. Am J Dent 13:25-30, 2000
  12. Kwong SM, Cheung GSP, Kei LH, Itthagatun A, Smales RJ, Tay FR. Micro-tensile bond strengths to sclerotic dentin using a self-etching and a total-etching technique. Dent Mater 18:359-369, 2002 https://doi.org/10.1016/S0109-5641(01)00051-3
  13. Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas P, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G. Adhesion to enamel and dentin: Current status and future challenges. Oper Dent 28:215-235, 2003
  14. Li H, Burrow MF, Tyas MJ, The effect of load cycling on the nanoleakage of dentin bonding systems. Dent Mater 18(2):111-119, 2002 https://doi.org/10.1016/S0109-5641(01)00029-X
  15. Prati C, Chersoni S, Mongiorgi R, Pashley DH. Resin-infiltrated dentin layer formation of new bonding systems. Oper Dent 23:185-194, 1998
  16. Tay FR, Pashley DH. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 17:296-308, 2001 https://doi.org/10.1016/S0109-5641(00)00087-7
  17. Yoshiyama M, Carvalho R, Sano H, Horner J, Brewer P, Pashley D. Regional bond strengths of resin human root dentin. J Dent Res 24:435-442, 1996 https://doi.org/10.1016/0300-5712(95)00102-6
  18. Yoshiyama M, Matsuo T, Ebisu S, Pashley D. Regional bond strengths of self-etching/self-priming adhesive systems. J Dent 26:609-616, 1998 https://doi.org/10.1016/S0300-5712(97)00046-8
  19. Shimada Y, Senawonge P, Harnirattisai C, Burrow MF, Nakaoki Y, Tagami J. Bond strength of two adhesive systems to primary and permanent enamel. Oper Dent 27:403-409, 2002
  20. Schreiner RF, Chappell RP, Glaros SG, Erick JD. Microtensile testing of dental adhesives. Dent Mater 14:194-201, 1998 https://doi.org/10.1016/S0109-5641(98)00030-X
  21. Van Noort R, Cardew GE, Howard IC, Noroozi S. The effect of local interfacial geometry on the measurement of the tensile bond strength to dentin. J Dent Res 70:889-893, 1991 https://doi.org/10.1177/00220345910700050501
  22. Erickson RL, Glasspoole EA. Bonding to tooth structure: a comparison of glass-ionomer and composite-resin system. J Esth Dent 6:227-244, 1994 https://doi.org/10.1111/j.1708-8240.1994.tb00864.x
  23. Sano H, Shono T, Sonoda H, Takatsu T, Ciccuchi B, Horner JA, Pashley DH. Tensile bond strength versus surface area for dentine bonding-Evaluation of a method using limited surface areas. Japan J Conserv Dent 37:882-887, 1994
  24. Tanumiharja M, Burrow MF, Tyas M. Microtensile bond strengths of glass ionomer(polyalkenoate) cements to dentin using four conditioners. J Dent 28:361-366, 2000 https://doi.org/10.1016/S0300-5712(00)00009-9
  25. Pashley DH, Carvalho RM, Sano H, Ciucchi B, Nakajima M, Yoshiyama M, Shono T, Fernades CA, Tay F. The micro-tensile bond test: a review. J Adhes Dent 1:299-309, 1999
  26. Phrukkanon S, Burrow MF, Tyas M. The influence of cross-sectional shape and surface area on the microtensile bond test. Dent Mater 14:212-222, 1998 https://doi.org/10.1016/S0109-5641(98)00034-7
  27. Miyazaki M, Onose H, Moore BK. Effect of operator variability on dentin bond strength of two-step bonding systems. Am J Dent 13:101-104, 2000
  28. Kanemura N, Sano H, Tagami J. Tensile bond strengths to and SEM evaluation of ground and intact enamel surface. J Dent 27:523-530, 1999 https://doi.org/10.1016/S0300-5712(99)00008-1
  29. Ogata M, Harada N, Yamaguchi S, Nakajima M, Pereira PNR, Tagami J. Effects of different burs on dentin bond strengths of bonding systems Oper Dent 26:375-382, 2001
  30. Toledano M, Osorio R, de Leonardi G, Rosales-Leal JI, Ceballos L, Cabrerizo-Vilchez MA. Influence of self-etching primer on the resin adhesion to enamel and dentin. Am J Dent 14(4):205-210, 2001
  31. Sano H, Yoshikawa T, Pereira PN, Kanemura M, Morigami M, Tagami J, Pashley DH. Long-term durability of dentin bonds made with a self-etching primer, in vivo. J Dent Res 78:906-911, 1999 https://doi.org/10.1177/00220345990780041101
  32. Agostini FG, Kaaden C, Powers JM. Bond strength of self-etching primers to enamel and dentin of primer teeth. Pediatric Dent 23:481-486, 2001
  33. Ferrari M, Mannocci F, Kugel G, Garcia-Godoy F. Standardized microscopic evaluation of the bonding mechanism of NRC/Prime & Bond NT. Am J Dent 12:77-83, 1999
  34. Rosa BT, Perdigao J. Bond strengths of nonrinsing adhesives. Quintessence Int 31:353-358, 2000
  35. Nikaido T, Kunzelmann KH, Chen H, Ofata M, Harada N, Yamaguchi S, Cox CF, Hickel R, Tagami J. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater 18:269-275, 2002 https://doi.org/10.1016/S0109-5641(01)00048-3
  36. Shono Y, Ogawa T, Terashita M, Carvalho RM, Pashley DH. Regional measurement of resin-dentin bonding as an array. J Dent Res 78:699-705, 1999 https://doi.org/10.1177/00220345990780021001
  37. Cardoso PEC, Braga RR. Carrilho MRO: Evaluation of micro-tensile, shear and tensile tests determining the bond strengths of three adhesive systems. Dent Mater 14:394-398, 1998 https://doi.org/10.1016/S0300-5712(99)00012-3
  38. Nunes MF, Swift JR EJ, Perdigao J, Effects of adhesive composition on microtensile bond strength to humam dentin, Am J Dent 14:340-343, 2001
  39. Pashley DH, Sano H, Ciucchi B, Yoshiyama M, Carvalho RM. Adhesion of testing of dentin bonding agents: a review. Dent Mater 11:117-125, 1995 https://doi.org/10.1016/0109-5641(95)80046-8
  40. Van Meerbeek B, Yoshiyama M, Inoue S, Vargas M, Fukuda R, Okazaki M, Lambrechts P, Vanherle G. Bonding mechanism and micro-tensile bond strength of a 4-MET-based self-etching adhesive. J Dent Res 79(Special Issue) abstract #845, p 249, 2000
  41. Yoshida Y, Van Meerbeek B, Nakayama Y, Snauwaert J, Hellemans L, Lambrechts P, Vanherle G, Wakasa K. Evidence of chemical bonding at biometerial-hard tissue interfaces. J Dent Res 79:709-714, 2000 https://doi.org/10.1177/00220345000790020301

Cited by

  1. Dental health capacity of the first permanent molars among children and adolescents in Korea for the year 2010 vol.37, pp.2, 2013, https://doi.org/10.11149/jkaoh.2013.37.2.103
  2. Logistic regression analysis of factors affecting the survival of first molars in Korean adults vol.39, pp.2, 2015, https://doi.org/10.11149/jkaoh.2015.39.2.88
  3. The utility of dental health capacity of the first permanent molars as an oral health indicator among children and adolescents vol.39, pp.3, 2015, https://doi.org/10.11149/jkaoh.2015.39.3.174