• Title/Summary/Keyword: Sd

Search Result 5,884, Processing Time 0.04 seconds

A 12b 200KHz 0.52mA $0.47mm^2$ Algorithmic A/D Converter for MEMS Applications (마이크로 전자 기계 시스템 응용을 위한 12비트 200KHz 0.52mA $0.47mm^2$ 알고리즈믹 A/D 변환기)

  • Kim, Young-Ju;Chae, Hee-Sung;Koo, Yong-Seo;Lim, Shin-Il;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.48-57
    • /
    • 2006
  • This work describes a 12b 200KHz 0.52mA $0.47mm^2$ algorithmic ADC for sensor applications such as motor controls, 3-phase power controls, and CMOS image sensors simultaneously requiring ultra-low power and small size. The proposed ADC is based on the conventional algorithmic architecture with recycling techniques to optimize sampling rate, resolution, chip area, and power consumption. The input SHA with eight input channels for high integration employs a folded-cascode architecture to achieve a required DC gain and a sufficient phase margin. A signal insensitive 3-D fully symmetrical layout with critical signal lines shielded reduces the capacitor and device mismatch of the MDAC. The improved switched bias power-reduction techniques reduce the power consumption of analog amplifiers. Current and voltage references are integrated on the chip with optional off-chip voltage references for low glitch noise. The employed down-sampling clock signal selects the sampling rate of 200KS/s or 10KS/s with a reduced power depending on applications. The prototype ADC in a 0.18um n-well 1P6M CMOS technology demonstrates the measured DNL and INL within 0.76LSB and 2.47LSB. The ADC shows a maximum SNDR and SFDR of 55dB and 70dB at all sampling frequencies up to 200KS/s, respectively. The active die area is $0.47mm^2$ and the chip consumes 0.94mW at 200KS/s and 0.63mW at 10KS/s at a 1.8V supply.

A Hardware Implementation of Image Scaler Based on Area Coverage Ratio (면적 점유비를 이용한 영상 스케일러의 설계)

  • 성시문;이진언;김춘호;김이섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.43-53
    • /
    • 2003
  • Unlike in analog display devices, the physical screen resolution in digital devices are fixed from the manufacturing. It is a weak point on digital devices. The screen resolution displayed in digital display devices is varied. Thus, interpolation or decimation of the resolution on the display is needed to make the input pixels equal to the screen resolution., This process is called image scaling. Many researches have been developed to reduce the hardware cost and distortion of the image of image scaling algorithm. In this paper, we proposed a Winscale algorithm. which modifies the scale up/down in continuous domain to the scale up/down in discrete domain. Thus, the algorithm is suitable to digital display devices. Hardware implementation of the image scaler is performed using Verilog XL and chip is fabricated in a 0.5${\mu}{\textrm}{m}$ Samsung SOG technology. The hardware costs as well as the scalabilities are compared with the conventional image scaling algorithms that are used in other software. This Winscale algorithm is proved more scalable than other image-scaling algorithm, which has similar H/W cost. This image-scaling algorithm can be used in various digital display devices that need image scaling process.

Clinical Efficacy of Toothpaste Containing Chitosan;Multicenter study (키토산 함유 치약의 임상적 효과;Multicenter study)

  • Kim, Min-Kyoung;Choi, Seong-Ho;Shin, Seung-Yun;Rhyu, In-Chul;Herr, Yeek;Park, Joon-Bong;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.167-178
    • /
    • 2003
  • Many researches are being done to study the effect of toothpaste containing natural extracts. The aim of this study was to evaluate the plaque control effect and therapeutic effect of toothpaste products containing chitosan extract. 120 healthy subjects with gingivitis or early periodontitis were divided into two groups. Subjects in the experimental group only used toothpaste containing chitosan and subjects in the control group used toothpaste without chitosan. At first, subjects received scaling and tooth brushing instruction. Gingival index, bleeding index, probing pocket depth, probing attachment level were scored at baseline, 2 months, and 3 months, and plaque index were scored at baseline, 1 month, 2 months, 3 months. Gingival index of experimental group and control group at baseline, 2 months, and 3 months use were 0.71${\pm}$0.66, 0.49${\pm}$0.55, 0.36${\pm}$0.49 and 0.62${\pm}$0.58, 0.51${\pm}$0.52, 0.48${\pm}$0.50 (mean${\pm}$SD), respectively (statistically significant different at p <0.05 ). Plaque index of experimental group and control group at baseline, 1 month, 2 months, and 3 months were 0.52${\pm}$0.50, 0.43${\pm}$0.50, 0.39${\pm}$0.49, 0.29${\pm}$0.46 and 0.49${\pm}$0.50, 0.50${\pm}$0.50, 0.51${\pm}$0.50, 0.45${\pm}$0.50, respectively (statistically significant different at p<0.05 ). Bleeding index of experimental group and control group were 0.40${\pm}$0.49, 0.33${\pm}$0.47, 0.24${\pm}$0.43 and 0.40${\pm}$0.49,0,38${\pm}$0.49,0.30${\pm}$0.46, respectively (statistically significant different at p<0.05). Probing depth of experimental group and control group were 2.41${\pm}$0.64, 2.31${\pm}$0.60, 2.28${\pm}$0.55 and 2.51${\pm}$0.67, 2.47${\pm}$0.63,2.42${\pm}$0.62, respectively (statistically significant different at p${\pm}$0.66, 2.32${\pm}$0.62 and 2.54${\pm}$0.70, 2.51${\pm}$0.69,2.46${\pm}$0.66, respectively (statistically significant different at p<0.05 ). From these finding, it can be concluded that toothpaste containing chitosan have better plaque control effect and therapeutic effect on gingivitis and early periodontitis compared to conventional toothpastes.

Translucency of ceramic veneers on glazing effect (세라믹 비니어의 글레이징에 따른 반투명도 변화)

  • Kim, Sung-Joon;Kahm, Se Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.138-143
    • /
    • 2015
  • Purpose: The aim of this study was to compare the translucency of two different laminate ceramic veneers with and without glazing. Materials and methods: Ten millimeter side square-shaped specimens in 0.3 mm and 0.6 mm thick were fabricated for the following materials with and without glazing (n=80): A1 shade IPS e.maxPress (IEM) and Styleveneers (STV). The color coordinates (CIE $L^*a^*b^*$) of the specimens were measured with a colorimeter. The Translucency parameter (TP) was calculated from the color difference of the material on a black versus a white background. For comparisons between materials and between the 'not glazed' and 'glazed' groups, unpaired t-test was used to analyze the data (P=.05). Results: The TP ($Mean{\pm}SD$) of 'not-glazed' and 'glazed' group of IEM specimens at 0.3 mm thickness were $45.99{\pm}3.00$ and $49.53{\pm}2.28$ and the TP at 0.6 mm thickness were $32.82{\pm}2.59$ and $43.02{\pm}0.98$, respectively. Likewise, the TP of 'not-glazed' and 'glazed' group of STV specimens at 0.3 mm thickness were $47.03{\pm}3.65$ and $50.95{\pm}3.05$ and the TP at 0.6 mm thickness group were $34.48{\pm}1.28$ and $43.39{\pm}1.20$, respectively. As the glazing of ceramic veneer differed, the TP of each ceramic veneer showed statistically significant difference. But, the result between the products was not statistically different. Conclusion: Within the limitations of this study, we are concluded that the glazing process changed translucency of laminate ceramic veneers and the TP would not be affected by products.

Inhibitory Effect of Rhus Verniciflua Extract on Lipid Peroxidation and Inflammatory Cytokines during Endurance Exercise Training (지구성 운동시 옻나무 추출액의 지질과산화 및 염증성사이토카인 억제효과)

  • Lee, Youn-Kyung;Kwon, Oh-Seon;Song, Young-Ju;Kim, Sea-Hyun;Kim, Pan-Gi;Ryu, Sung-Pil
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.102-110
    • /
    • 2010
  • This study was performed to find out the inhibitory effect of Rhus Verniciflua extract on lipid peroxidation and inflammatory cytokines during endurance exercise training for 8 weeks in rats. For this study, Sprague-Dawley rats were divided into 4 groups; sedentary (SED), exercise training (TRA), RVS extract ingestion (RVE), and RVS extract ingestion and exercise training (RVE-TRA). TRA and RVE-TRA were trained on treadmill with increasing speed gradually and administered 10 mL/kg/d of Rhus Verniciflua extract orally to RVE and RVE-TRA. In order to analyze antioxidant function, blood SOD (superoxide dismutase), GSH-Px (glutathione peroxidase), and MDA (malondialdehyde) were examined. And, analysis of inflammatory cytokines were examined using IL-6 (interleukin-6), TNF-${\alpha}$ (tumor necrosis factor-alpha), CRP (C-reactive protein), and NO (nitric oxide). SOD in TRA was significantly higher than SED and RVE (p<0.05), and RVE-TRA was highest among the groups (p<0.05). The MDA content of TRA, RVE and RVE-TRA were significantly lower than SED. GSH-Px activity of SED was significantly lower than other groups (p<0.05). IL-6 and TNF-${\alpha}$ content of RVE and RVE-TRA were significantly lower than SED and TRA (p<0.05). CRP concentration of SED was the lowest among groups (p<0.05). Finally, NO concentration of SED and TRA were higher than RVE and RVE-TRA (p<0.05). These results suggested that it is efficient for rats to reduce lipid peroxidation and induce anti-inflammatory by taking RVS extract during exercise training. Afterwards, if studies on the properties of RVS extract can be made with various ways, use of Rhus Verniciflua trees might be made widely which are growing naturally in mountains in Korea.

Inhibitory Effects of Chios Mastic Gum on Gastric Acid Secretion by Histamine-Related Pathway in a Rat Model and Primary Parietal Cells (위염 동물모델과 위 벽세포에서 히스타민 경로를 통한 매스틱검(Chios Mastic Gum)의 위산 분비 억제효과 및 기전 연구)

  • Nam, Da-Eun;Kim, Ok Kyung;Shim, Tae Jin;Lee, Jum Kyun;Hwang, Kwon-Tack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1500-1509
    • /
    • 2014
  • The object of this study was to investigate the inhibitory effects of chios mastic gum (MG) on gastric acid secretion in an ethanol-induced SD rat model and primary parietal cells. Rats were randomly divided into four groups: Vehicle (normal group), Control (treated with ethanol), MG50 (treated with ethanol and mastic gum at 50 mg/kg b.w), MG100 (treated with ethanol and mastic gum at 100 mg/kg b.w). Groups treated with both MG50 and MG100 showed attenuation of gastric mucosal injury, sub-epithelial loss, hemorrhaging, and gastric juice secretion. We also examined the acidity of gastric juice during gastric injury. Oral administration of both MG50 and MG100 significantly decreased acidity of gastric juice by % and %, respectively. To examine the stimulatory factors related to gastric acid secretion, mRNA expression levels of H2r, M3r, CCK2r, and $H^+/K^+$ ATPase were measured by real-time PCR. Compared with a vehicle group, mRNA expression levels of H2r, CCK2r, and $H^+/K^+$ ATPase clearly increased in the control group. However, levels of H2r, CCK2r, and $H^+/K^+$ ATPase slightly but significantly decreased in MG-treated groups compared with control. Blood level of histamine significantly decreased in MG-treated groups, which indicates the involvement of MG on in histamine-related acid secretion. To identify the mode of action of MG in regulating histamine-related pathways, intracellular level of cAMP and mRNA levels of H2r, M3r, CCK2r, and $H^+/K^+$ ATPase were measured in primary parietal cells. While mRNA levels of M3r and CCK2r remained unchanged, levels of H2r and $H^+/K^+$ ATPase significantly decreased upon MG treatment. Subsequently, intracellular levels of cAMP decreased. These results suggest that mastic gum has the ability to inhibit gastric acid secretion by regulating a histamine-related pathway.

THE LUMINOSITY-LINEWIDTH RELATION AS A PROBE OF THE EVOLUTION OF FIELD GALAXIES

  • GUHATHAKURTA PURAGRA;ING KRISTINE;RIX HANS-WALTER;COLLESS MATTHEW;WILLIAMS TED
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.63-64
    • /
    • 1996
  • The nature of distant faint blue field galaxies remains a mystery, despite the fact that much attention has been devoted to this subject in the last decade. Galaxy counts, particularly those in the optical and near ultraviolet bandpasses, have been demonstrated to be well in excess of those expected in the 'no-evolution' scenario. This has usually been taken to imply that galaxies were brighter in the past, presumably due to a higher rate of star formation. More recently, redshift surveys of galaxies as faint as B$\~$24 have shown that the mean redshift of faint blue galaxies is lower than that predicted by standard evolutionary models (de-signed to fit the galaxy counts). The galaxy number count data and redshift data suggest that evolutionary effects are most prominent at the faint end of the galaxy luminosity function. While these data constrain the form of evolution of the overall luminosity function, they do not constrain evolution in individual galaxies. We are carrying out a series of observations as part of a long-term program aimed at a better understanding of the nature and amount of luminosity evolution in individual galaxies. Our study uses the luminosity-linewidth relation (Tully-Fisher relation) for disk galaxies as a tool to study luminosity evolution. Several studies of a related nature are being carried out by other groups. A specific experiment to test a 'no-evolution' hypothesis is presented here. We have used the AUTOFIB multifibre spectro-graph on the 4-metre Anglo-Australian Telescope (AAT) and the Rutgers Fabry-Perot imager on the Cerro Tolalo lnteramerican Observatory (CTIO) 4-metre tele-scope to measure the internal kinematics of a representative sample of faint blue field galaxies in the red-shift range z = 0.15-0.4. The emission line profiles of [OII] and [OIII] in a typical sample galaxy are significantly broader than the instrumental resolution (100-120 km $s^{-l}$), and it is possible to make a reliable de-termination of the linewidth. Detailed and realistic simulations based on the properties of nearby, low-luminosity spirals are used to convert the measured linewidth into an estimate of the characteristic rotation speed, making statistical corrections for the effects of inclination, non-uniform distribution of ionized gas, rotation curve shape, finite fibre aperture, etc.. The (corrected) mean characteristic rotation speed for our distant galaxy sample is compared to the mean rotation speed of local galaxies of comparable blue luminosity and colour. The typical galaxy in our distant sample has a B-band luminosity of about 0.25 L$\ast$ and a colour that corresponds to the Sb-Sd/Im range of Hub-ble types. Details of the AUTOFIB fibre spectroscopic study are described by Rix et al. (1996). Follow-up deep near infrared imaging with the 10-metre Keck tele-scope+ NIRC combination and high angular resolution imaging with the Hubble Space Telescope's WFPC2 are being used to determine the structural and orientation parameters of galaxies on an individual basis. This information is being combined with the spatially resolved CTIO Fabry-Perot data to study the internal kinematics of distant galaxies (Ing et al. 1996). The two main questions addressed by these (preliminary studies) are: 1. Do galaxies of a given luminosity and colour have the same characteristic rotation speed in the distant and local Universe? The distant galaxies in our AUTOFIB sample have a mean characteristic rotation speed of $\~$70 km $s^{-l}$ after correction for measurement bias (Fig. 1); this is inconsistent with the characteristic rotation speed of local galaxies of comparable photometric proper-ties (105 km $s^{-l}$) at the > $99\%$ significance level (Fig. 2). A straightforward explanation for this discrepancy is that faint blue galaxies were about 1-1.5 mag brighter (in the B band) at z $\~$ 0.25 than their present-day counterparts. 2. What is the nature of the internal kinematics of faint field galaxies? The linewidths of these faint galaxies appear to be dominated by the global disk rotation. The larger galaxies in our sample are about 2"-.5" in diameter so one can get direct insight into the nature of their internal velocity field from the $\~$ I" seeing CTIO Fabry-Perot data. A montage of Fabry-Perot data is shown in Fig. 3. The linewidths are too large (by. $5\sigma$) to be caused by turbulence in giant HII regions.

  • PDF

Correlation of Exercise-Induced Bronchoconstriction to $PC_{20}$ and Maximal Airway Narrowing on the Dose-Response Curve to Methacholine (운동유발성 기관지수축의 정도와 Methacholine 유발시험의 민감도 및 최대기도협착과의 관련성)

  • Lim, Hyung-Suk;Yoon, Kyung-Ae;Koh, Young-Yull
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 1995
  • Background: Exercise is one of the most common precipitants of acute asthma encountered in clinical practice. The development of airflow limitation that occurs several minutes after vigorous exercise, i. g. exercise-induced bronchoconstriction(EIB), has been shown to be closely correlated with the nonspecific bronchial hyperresponsiveness, which is the hallmark of bronchial asthma. All previous reports that assessed the correlation of EIB to nonspecific bronchial hyperresponsiveness have focused on airway sensitivity($PC_{20}$) to inhaled bronchoconstrictor such as methacholine or histamine. However, maximal airway narrowing(MAN), reflecting the extent to which the airways can narrow, when being exposed to high dose of inhaled stimuli, has not been studied in relation to the degree of EIB. Methods: Fifty-six children with mild asthma(41 boys and 15 girls), aged 6 to 15 years(mean${\pm}$SD, $9.9{\pm}2.5$ years) completed this study. Subjects attended the laboratory on two consecutive days. Each subject performed the high-dose methacholine inhalation test at 4 p.m. on the first day. The dose-response curves were characterized by their position($PC_{20}$) and MAN, which was defined as maximal response plateau(MRP: when two or three data points of the highest concentrations fell within a 5% response range) or the last of the data points(when a plateau could not be measured). On the next day, exercise challenge, free running outdoors for ten minutes, was performed at 9 a.m.. $FEV_1$ was measured at graduated intervals, 3 to 10 minutes apart, until 60 minutes after exercise. Response(the maximal ${\triangle}FEV_1$ from the pre-exercise value) was classified arbitrarily into three groups; no response((-) EIB: ${\triangle}FEV_1$<10%), equivocal response ($({\pm})$EIB:10%<${\triangle}FEV_1$<20%) and definite response($({\pm})$EIB:${\triangle}FEV_1$>20%). Results: 1) When geometric mean $PC_{20}$ of the three groups were compared, $PC_{20}$ of (+) EIB group was significantly lower than that of (-)EIB group. 2) There was a close correlation between $PC_{20}$ and the severity of EIB in the whole group(r=-0.568, p<0.01). 3) Of the total 56 subjects, MRP could be measured in 36 subjects, and the MRP of these subjects correlated fairly with the severity of EIB(r=0.355, p<0.05) 4) The MAN of (+) EIB group was significantly higher than that of (-)EIB group(p<0.01). 5) The MAN correlated well with the severity of EIB in the whole group(r=0.546, p<0.01). Conclusion: The degree of MAN as well as bronchial sensitivity($PC_{20}$) to methacholine is correlated well with the severity of EIB. The results suggest that the two main components of airway hyperresponsiveness may be equally important determinants of exercise reactivity, although the mechanism may be different from each other. The present study also provides further evidence that EIB is a manifestation of the increased airway reactivity characteristic of bronchial asthma.

  • PDF

Clinical Significance of Nasal Peak Inspiratory Flow Rate in Patients with Chronic Cough (만성기침환자에서 비강최대흡기유속 측정의 의의)

  • An, Chang-Hyeok;Lee, Byung-Hun;Park, Yong-Bum;Choi, Jae-Chul;Jee, Hyun-Suk;Park, Sung-Jin;Kang, Sun-Bok;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whi;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.654-661
    • /
    • 1999
  • Background : The upper respiratory tract is the primary target organ of various airborne pollutants and is easily accessible part of the respiratory tract, and also is the predominant structure where chronic cough originates. The nasal peak inspiratory flow(PIFn), which is the peak inspiratory flow via nose with nasal mask and spirometry, could be a reliable parameter of nasal obstruction. The validity of PIFn has been evaluated in several studies by assessing the correlation between PIFn measurements and other parameters of nasal air flow. This study was designed to show the reproducibility of PIFn, the difference of PIFn between patients with chronic cough and normal subjects, and the usefulness of PIFn in the evaluation of nasal obstruction in patients with chronic cough. Methods : PIFn was measured by spirometry with nasal mask, twice a day for 3 consecutive days in 7 young normal subjects to evaluate validity of the test. In 32 patients with chronic cough and 25 age-matched normal subjects, PIFn and pulmonary function test($FEV_1$, $FEV_1%$ pred, FVC, and FVC% pred) were measured at first visiting. Results : Values of PIFn, $FEV_1$, and FVC were nearly constant in 7 young normal adults. Patients with chronic cough were 32 (14 males and 18 females) and the mean age was $41.4{\pm}15.9$ years. Normal subjects were 32(22 males and 10 females) and the mean age was $39.8{\pm}18.6$ years. There was no significant difference of age and pulmonary function test between patients with chronic cough and normal subjects(p<0.05). The PIFn values in patients with chronic cough was significantly lower than those of normal subjects($2.25{\pm}0.68\;L/sec$ vs. $2.75{\pm}1.00\;L/sec$ ; p=0.02). The postnasal drip syndrome(PNDS) comprised the majority of patients with chronic cough(27). The PIFn in patients with PNDS was significantly lower than that of normal subjects (mean$\pm$SD ; $2.18{\pm}0.66$ vs. $2.75{\pm}1.00\;L/sec$, p=0.006). Conclusion : There was a significant difference of PIFn between patients with chronic cough and normal subjects. Among the patients with chronic cough, patients with PNDS showed the most significant difference with normal subjects in PIFn. The PIFn could be a useful parameter of nasal obstruction in patients with chronic cough, especially in patients with PNDS.

  • PDF

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF