• 제목/요약/키워드: Scattering parameters

검색결과 436건 처리시간 0.029초

Monte-Carlo Simulation for dust scattering in the Ophiuchus molecular complex

  • Lim, Tae-Ho;Min, Kyoung-Wook;Seon, Kwang-Il
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.71.2-71.2
    • /
    • 2010
  • We present the results of FUV dust scattering simulation, which is based on the Monte-Carlo method. In this simulation, we focus on the multiple scattering in the Ophiuchus complex region because the single scattering case in the region already reported by Lee et al. 2008. We compare the simulation result to the FUV intensity with FIMS and the single scattering result. We also discuss the parameters related to the results of this simulation, such as asymmetry factor, albedo and other different setting-ups.

  • PDF

태양전지 실리콘 웨이퍼에서의 레일리기준 기반 레이저산란 패턴 분석 및 결함 검출 (Investigation of Laser Scattering Pattern and Defect Detection Based on Rayleigh Criterion for Crystalline Silicon Wafer Used in Solar Cell)

  • 연정승;김경범
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.606-613
    • /
    • 2011
  • In this paper, patterns of laser scattering and detection of micro defects have been investigated based on Rayleigh criterion for silicon wafer in solar cell. Also, a new laser scattering mechanism is designed using characteristics of light scattering against silicon wafer surfaces. Its parameters are to be optimally selected to obtain effective and featured patterns of laser scattering. The optimal parametric ranges of laser scattering are determined using the mean intensity of laser scattering. Scattering patterns of micro defects are investigated at the extracted parameter region. Among a lot of pattern features, both maximum connected area and number of connected component in patterns of laser scattering are regarded as the important information for detecting micro defects. Their usefulness is verified in the experiment.

G-Band 도파관 산란 계수 정밀 측정 (Precise Measurements of Waveguide Scattering Parameters in G-Band)

  • 강진섭;김정환;조치현;김대찬
    • 한국전자파학회논문지
    • /
    • 제24권9호
    • /
    • pp.892-899
    • /
    • 2013
  • 본 논문에서는 (서브)밀리미터파 대역에서 산란 계수 정밀 측정이 어려운 요인 및 보다 정확한 측정을 하기 위한 방안을 기술하였으며, G-band(140~220 GHz)에서의 측정 사례를 제시하였다. 우선 마이크로파 대역과 (서브)밀리미터파 대역에서 사용되는 산란 계수 측정시스템(벡터회로망 분석기)의 동작 원리에 대한 차이점을 파악하고, (서브)밀리미터파 대역 산란 계수 측정시스템을 보다 잘 운영하기 위한 방안을 기술하였다. 그리고 더 좋은 도파관 전송 특성 및 연결 반복도를 얻기 위한 방안과 반사 계수 크기가 작은 피측정기를 정밀 측정하기 위한 방안을 기술하였다.

Physical interpretation on eigen-parameters of polarimetric SAR data for microwave scattering from leaf

  • Park, Sang-Eun;Moon, Wooil M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.316-318
    • /
    • 2003
  • An eigen-analysis of the coherency matrix provides the polarimetric scattering mechanisms with the matrix characterizing parameters. In this paper, the coherency matrices of deciduous and coniferous vegetation are calculated using the analytical method. The Generalized Rayleigh-Gans approximation is used to model backscattering from distributed coniferous and deciduous leaves. The characteristics of eigen-parameters of simulated coherency matrix for deciduous and coniferous leaves with respect to the leaf shapes and orientations are illustrated.

  • PDF

혼탁 매질에서 광산란에 의한 광학적 파라미터들의 측정에 관한 연구 (Studies on the Measurements of Optical Parameters in Turbid Material by Light Scattering)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.151-156
    • /
    • 1995
  • The influences of fluorophor, scatterer, absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by laser induced fluorescence spectroscopy. It has been found that the effects of optical properties in scattering media by the optical parameters(${\mu}_{s}$, ${\mu}_{a}$, ${\mu}_{t}$). The value of scattering coefficient ${\mu}_{s}$ is large by means of the increasing particles of scatterer, it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, laser medicine and application of medical engineering.

ISO 방법론 및 1:10 축소잔향실을 이용한 확산률 측정 (Measuring Scattering Coefficient in 1:10 Reverberation Chamber Using the ISO Method)

  • 전진용;이병권;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.252-256
    • /
    • 2001
  • Scattering of surface materials has been known as one of the most important aspects in evaluating the acoustics of concert halls are designed. One of the methods that can reduce the errors in estimating the reverberation time and other acoustic parameters through computer modeling is to calculate scattering coefficient of surface materials. However. so far, no objective and reliable methods measuring scattering coefficient has been suggested. In this situation, ISO has suggested the method of measuring the random-incidence scattering coefficient on surfaces in diffuse field, whereas AES has introduced a method on directional-incidence in free field. In this study, the scattering coefficients of five kinds of hemispheres (1.5, 2.0. 2.5. 3.0. 3.5cm) were measured by using the ISO method in 1:10 reverberation chamber. It was found that 3.0cm hemisphere has the highest scattering coefficient satisfying 95% reliability.

  • PDF

토양 표면에서의 편파별 후방 산란 계수 측정을 통한 산란 모델과 Inversion 알고리즘의 검증 (Verification of Surface Scattering Models and Inversion Algorithms with Measurements of Polarimetric Backscattering Coefficients of a Bare Soil Surface)

  • 홍진영;정승건;오이석
    • 한국전자파학회논문지
    • /
    • 제17권12호
    • /
    • pp.1172-1180
    • /
    • 2006
  • 본 논문은 풀이 없는 지표면에서의 후방 산란 계수(backscattering coefficients)를 측정하고, 이 측정 결과를 이용하여 여러 표면 산란 모델들과 inversion 알고리즘의 성능을 비교, 분석하였다. 우선, R-밴드 주파수($1.7{\sim}2.0GHz$)에서 완전 편파 scatterometer를 이용하여 풀 층이 없는 지표면에 대해서 편파별로 후방 산란 계수를 측정하고, 동시에 수분 함유량과 표면 거칠기를 측정하였다. 그런 다음 측정된 지표면 변수들을 표면 산란 모델들에 입력하여 후방 산란 계수를 계산하고, 이 계산 결과를 측정 결과와 비교 분석하였다. 또한, inversion 알고리즘들을 적용하여 측정된 편파별 후방 산란 계수로부터 수분 함유량을 추출하고, 이 추출된 수분 함유량이 현장에서 측정한 수분 함유량과 잘 맞는지 여부를 확인하였다. 표면 산란 모델들 중에서 정확도가 높은 모델들을 제시하였으며, inversion 모델들의 계산 결과도 나타내었다.

Radar Remote Sensing of Soil Moisture and Surface Roughness for Vegetated Surfaces

  • Oh, Yi-Sok
    • 대한원격탐사학회지
    • /
    • 제24권5호
    • /
    • pp.427-436
    • /
    • 2008
  • This paper presents radar remote sensing of soil moisture and surface roughness for vegetated surfaces. A precise volume scattering model for a vegetated surface is derived based on the first-order radiative transfer technique. At first, the scattering mechanisms of the scattering model are analyzed for various conditions of the vegetation canopies. Then, the scattering model is simplified step by step for developing an appropriate inversion algorithm. For verifying the scattering model and the inversion algorithm, the polarimetric backscattering coefficients at 1.85 GHz, as well as the ground truth data, of a tall-grass field are measured for various soil moisture conditions. The genetic algorithm is employed in the inversion algorithm for retrieving soil moisture and surface roughness from the radar measurements. It is found that the scattering model agrees quite well with the measurements. It is also found that the retrieved soil moisture and surface roughness parameters agree well with the field-measured ground truth data.

입자 이동 방식에서 Laser Induced Fluorescence와 뭉침에 관한 연구 (A Study on Laser Induced Fluorescence and Coagulation in Particle Transport Mode)

  • 김기준
    • 한국응용과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.340-346
    • /
    • 2006
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF). The effects of optical properties in scattering media have been found by the optical $parameters({\mu}_s,\;{\mu}_a,\;{\mu}_t)$. Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process, The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, biopharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

산업재해 방지를 위한 New Austria Tunnel Method 수지에서 빔산란에 의한 Monte Carlo 시뮬레이션에 관한 연구 (A Study on Monte Carlo Simulation by beam scattering in Resin of New Austria Tunnel Method for Safety of Industrial Disaster)

  • 남상성;이주엽
    • 한국응용과학기술학회지
    • /
    • 제30권3호
    • /
    • pp.444-450
    • /
    • 2013
  • The influences of scatterer and absorber in turbid material by light scattering on silica fume of additive were interpreted for the scattered intensity and wavelength. The molecular properties have been studied by Monte Carlo simulation in resin of New Austria Tunnel Method. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_s$, ${\mu}_a$,${\mu}_t$). Monte Carlo Simulation method for modelling of light transport in the civil engineering and construction field was applied. The results using a phantom were discussed that the distance from source to detector is closer, and scattering intensity is stronger with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for coatings and corrosion for the durability of metal constructions.