• Title/Summary/Keyword: Scanning height

Search Result 248, Processing Time 0.028 seconds

Penetration of ACQ Treatment and its Effect of Degradation on Wood Tissues (Structure) (ACQ 약제의 목재 내 침투 및 부후 특성에 미치는 목재 조직의 영향)

  • Lee, Hyun-Mi;Lee, Dong-Heub;Hwang, Won-Joung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.576-582
    • /
    • 2013
  • To obtain the basic information on wood preservative process using copper, the penetration ACQ-2 preservative agent into Douglas fir wood and its degradational characteristics were investigated. Douglas fir is known to be difficult for preservative agent injection. To find the hindrance factor of the preservatives movement, the ray height, ray density, and length of tracheid were measured and observed by a stereoscopic microscope and scanning electron microscope. The results were compared in the well-penetrated parts of preservatives and insufficient parts. There were no significant differences in height, length, and density between both parts, except for the pits of the wood elements observed in SEM micrograph. More declosed pits were found in the well-penetrated parts of preservatives. Decay characteristics of wood specimen treated with various ACQ concentrations by brown-rot fungi was observed by an optical microscope. The decayed properties of tracheid, rays, and resin canals was found in the non-treated wood specimens and it was also found that some extent of preservatives concentration is necessary to protect the decay.

A STUDY ON THE RELATIONS OF VARIOUS PARTS OF THE PALATE FOR PRIMARY AND PERMANENT DENTITION (유치열과 영구치열의 구개 각부의 관계에 관한 연구)

  • Lee, Yong-Hoon;Yang, Yeon-Mi;Lee, Yong-Hee;Kim, Sang-Hoon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.569-578
    • /
    • 2004
  • The purpose of this study was to clarify the palatal arch length, width and height in the primary and permanent dentition. Samples were consisted of normal occlusions both in the primary dentition(50 males and 50 females) and in the permanent dentition(50 males and 50 females). With their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve and loft surface, fit and horizontal plane were based to measure the palatal arch length, width and height(Surfacer 10.0, Imageware, U.S.A.). T-tests were applied for the statistical analyze of the data. The results were as follows : 1. In the measurement values, the values of the male were higher than those of the female except primary anterior palatal height. There were not only statistically significant differences in anterior palatal width(p<0.05) and posterior palatal width(p<0.01) in primary dentition but palatal width(p<0.05), anterior palatal length(p<0.01), middle and posterior palatal length(p<0.05) in permanent dentition between male and female. 2. In the indices of palate, there were statistically significant differences in height-length index(p<0.05) and width-length index(p<0.01) between male and female in primary dentition. In permanent dentition, there was statistically difference between male and female. 3. In the measurement values, posterior palatal width was increased most greatly. Posterior palatal height, anterior palatal width and anterior palatal length were followed by descending order. On the other hand, anterior palatal height and posterior palatal length were decreased. 4. In the indices of palate, the height-length index, the width-length index and posterior height-width index were increased, but the others were decreased.

  • PDF

Property and Microstructure Evolution of Nickel Silicides on Nano-thick Polycrystalline Silicon Substrates (나노급 다결정 실리콘 기판 위에 형성된 니켈실리사이드의 물성과 미세구조)

  • Kim, Jong-Ryul;Choi, Young-Youn;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We fabricated thermally-evaporated 10 nm-Ni/30 nm and 70 nm Poly-Si/200 nm-$SiO_2/Si$ structures to investigate the thermal stability of nickel silicides formed by rapid thermal annealing(RTA) of the temperature of $300{\sim}1100^{\circ}C$ for 40 seconds. We employed for a four-point tester, field emission scanning electron microscope(FE-SEM), transmission electron microscope(TEM), high resolution X-ray diffraction(HRIXRD), and scanning probe microscope(SPM) in order to examine the sheet resistance, in-plane microstructure, cross-sectional microstructure evolution, phase transformation, and surface roughness, respectively. The silicide on 30 nm polysilicon substrate was stable at temperature up to $900^{\circ}C$, while the one on 70 nm substrate showed the conventional $NiSi_2$ transformation temperature of $700^{\circ}C$. The HRXRD result also supported the existence of NiSi-phase up to $900^{\circ}C$ for the Ni silicide on the 30 nm polysilicon substrate. FE-SEM and TEM confirmed that 40 nm thick uniform silicide layer and island-like agglomerated silicide phase of $1{\mu}m$ pitch without residual polysilicon were formed on 30 nm polysilicon substrate at $700^{\circ}C\;and\;1000^{\circ}C$, respectively. All silicides were nonuniform and formed on top of the residual polysilicon for 70 nm polysilicon substrates. Through SPM analysis, we confirmed the surface roughness was below 17 nm, which implied the advantage on FUSI gate of CMOS process. Our results imply that we may tune the thermal stability of nickel monosilicide by reducing the height of polysilicon gate.

Scattered Point Noise Filtering Method for Image Reconstruction Performance Enhancing of White Light Interfrometry (높이영상에 산포되어 있는 점 노이즈 처리를 통한 백색광 간섭계의 영상 복원력 향상)

  • Yim, Hae-Dong;Lee, Min-Woo;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • In this paper, in order to enhance the image reconstruction performance of white light scanning interferometry(WLI), we demonstrate the scattered point noise filtering performance of post-processing methods. Median filtering is similar to using an averaging filter. Because the median value is less sensitive than the mean to extreme values, the median filter can remove the scattered point noise from a height-map without significantly reducing the sharpness of the image. In several specific cases, however, the median filter can't remove the scattered point noise. Therefore, we propose a comparative mean filter that uses order-statistic filtering and the mean of the neighborhood pixels. The performance is demonstrated by measuring an array of metal solder balls fabricated on PCB. The proposed method reduced the noise pixels by 4.4 percent.

A Study on the Back shape and self-conscious symptoms of the students in S High school Using the Moire measurement and Questionnaire investigation (모아레 측정법과 설문지 조사를 통한 경기도 S고등학교 재학생의 신체자각증상과 배부체형에 대한 실태조사)

  • Chang, Gyu-Tae;Kim, Jang-Hyun;Baek, Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.55-74
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the back shape and self-conscious symptoms of the students in S High school using the phase-shifting scanning grating projection Moire interferometer and Questionnaire investigations. Methods : In this study the subjects consisted of 317 pupils[168 boys(53%), 149girls(47%)] attending S high school in Sungnamsi, Kyoungkido in 2002. Their ages ranged from sixteen to eighteen. With the phase-shifting scanning grating projection moire interferometer, the posterior views of the body were taken to see if there are correlation of remainder value of the height spot of left & right shoulder blade and gluteal region in Moire topography. And using questionnaire investigation, we investigated the self-conscious symptoms. Results : 1. In questionnaire investigation, we observed that the ratios of self-conscious symptoms of girls are more than that of boys. The ratios of headache, neck pain, lower back pain, digestive symptom were more than 70% in boys and girls. 2. In Moire topography, more frequent findings of scapular region were observed that left scapular area were higher than right(in boys 69.3%, 60%, 100%, aged 16,17,18, in girls 66.8%, 40.5%, 58.8% aged 16,17,18). 3. More frequent findings of gluteal region were observed that left scapular area were higher than right(in boys 75.2%, 60%, 36.4% aged 16,17,18, in girls 61.1%, 46.8%, 64.7% aged 16,17,18) 4. More frequent findings of reminder value of the vertical lines of cervical and buttock region in Moire topography were observed that the vertical lines of cervical region were inclined to left than the vertical lines of buttock(in boys 73.3%, 92.2%, 100% aged 16,17,18, in girls 72.2%, 77.2%, 73.5% aged 16,17,18) Conclusion : From these results, we found that the self-conscious symptoms were more than in girls than boys; the ratio of headache, neck pain, Lower back pain, digestive symptom was more than the others; the back shape of high school students were not balanced in scapular and buttock region; necks were inclined to left than buttock.

  • PDF

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

The effect of Zirconium Nitride coating on shear bond strength with denture base resin in Co-Cr alloy and titanium alloy (질화 지르코늄 코팅이 코발트 크롬 합금과 타이타늄 합금에서 의치상 레진과의 전단결합강도에 미치는 영향)

  • Park, Chan;Lee, Kyoung-Hun;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate of Zirconium Nitride (ZrN) coating on shear bond strength with denture base resin in Co-Cr and Ti-6Al-4V alloy. Materials and Methods: Co-Cr and Ti-6Al-4V alloy disks (10 mm in diameter, 2.5 mm in thickness; each other: n = 14) were prepared and divided with 2 groups each other by ZrN coating. After primer was applied to disks surface, denture base resin with diameter 6 mm, height 5 mm was bonded on metal disk surface. After surface roughness was measured by Profiler, shear bond strength was determined with Universal testing machine and analyzed with two-way ANOVA. The specimen surfaces and failure mode were examined using a scanning electron microscope. Results: ZrN coated groups showed significantly higher rough surface than non-coated groups (P < 0.05). Irrespective of alloy materials, shear bond strength of ZrN coated groups were lower than non-coated groups (P < 0.001). The scanning electron microscope (SEM) of ZrN coated groups showed mixed and adhesive fractures. Conclusion: ZrN coating weakened bonding strength between denture base resin and Co-Cr, Ti-6Al-4V alloy.

Effects of maize straw treated with various levels of CaO and moisture on composition, structure, and digestion by in vitro gas production

  • Shi, Mingjun;Ma, Zhanxia;Tian, Yujia;Zhang, Xuewei;Shan, Huiyong
    • Animal Bioscience
    • /
    • v.34 no.12
    • /
    • pp.1940-1950
    • /
    • 2021
  • Objective: The objective of this study was to explore the effects of maize straw treated with calcium oxide (CaO) and various moisture, on the composition and molecular structure of the fiber, and gas production by fermentation in an in vitro rumen environment. Methods: The experiment used 4×3 Factorial treatment. Maize straws were treated with 4 concentrations of CaO (0%, 3%, 5%, and 7% of dry straw weight) and 3 moisture contents (40%, 50%, and 60%). Scanning electron microscopy, Fourier transform infrared spectroscopy and X-ray fluorescence spectroscopy were employed to measure the surface texture, secondary molecular structure of carbohydrate, and calcium (Ca) content of the maize straw, respectively. The correlation of secondary molecular structures and fiber components of maize straw were analyzed by CORR procedure of SAS 9.2. In vitro rumen fermentation was performed for 6, 12, 24, 48, and 72 h to measure gas production. Results: Overall, the moisture factor had no obvious effect on the experimental results. Neutral detergent fiber (NDF), acid detergent fiber, acid detergent lignin, hemicellulose and cellulose contents decreased (p<0.05) with increasing concentrations of CaO treatment. Surface and secondary molecular structure of maize straw were affected by various CaO and moisture treatments. NDF had positive correlation (p<0.01) with Cell-H (H, height), Cell-A (A, area), CHO-2-H. Hemicellulose had positive correlation (p<0.01) with Lignin-H, Lignin-A, Cell-H, Cell-A. Ca content of maize straw increased as the concentration of CaO was increased (p<0.01). Gas production was highest in the group treated with 7% CaO. Conclusion: CaO can adhere to the surface of the maize straw, and then improve the digestibility of the maize straw in ruminants by modifying the structure of lignocellulose and facilitating the maize straw for microbial degradation.

The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin

  • Su, Naichuan;Yue, Li;Liao, Yunmao;Liu, Wenjia;Zhang, Hai;Li, Xin;Wang, Hang;Shen, Jiefei
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.214-223
    • /
    • 2015
  • PURPOSE. To measure the surface loss of dental restorative zirconia and the short-term bond strength between an indirect composite resin (ICR) and zirconia ceramic after various sandblasting processes. MATERIALS AND METHODS. Three hundred zirconia bars were randomly divided into 25 groups according to the type of sandblasting performed with pressures of 0.1, 0.2, 0.4 and 0.6 MPa, sandblasting times of 7, 14 and 21 seconds, and alumina powder sizes of 50 and $110{\mu}m$. The control group did not receive sandblasting. The volume loss and height loss on zirconia surface after sandblasting and the shear bond strength (SBS) between the sandblasted zirconia and ICR after 24-h immersion were measured for each group using multivariate analysis of variance (ANOVA) and Least Significance Difference (LSD) test (${\alpha}$=.05). After sandblasting, the failure modes of the ICR/zirconia surfaces were observed using scanning electron microscopy. RESULTS. The volume loss and height loss were increased with higher sandblasting pressure and longer sandblasting treatment, but they decreased with larger powder size. SBS was significantly increased by increasing the sandblasting time from 7 seconds to 14 seconds and from 14 seconds to 21 seconds, as well as increasing the size of alumina powder from $50{\mu}m$ to $110{\mu}m$. SBS was significantly increased from 0.1 MPa to 0.2 MPa according to the size of alumina powder. However, the SBSs were not significantly different with the sandblasting pressure of 0.2, 0.4 and 0.6 MPa. The possibilities of the combination of both adhesive failure and cohesive failure within the ICR were higher with the increases in bonding strength. CONCLUSION. Based on the findings of this study, sandblasting with alumina particles at 0.2 MPa, 21 seconds and the powder size of $110{\mu}m$ is recommended for dental applications to improve the bonding between zirconia core and ICR.

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.