• Title/Summary/Keyword: Scanning height

Search Result 248, Processing Time 0.022 seconds

Effect of polishing solution temperature and times by electro-polishing in dental casting Co-Cr-Mo alloy (치과 주조용 Co-Cr-Mo alloy에서 전해용액 온도와 전해시간에 따른 전해연마의 특성)

  • Jang, Jae-Young;Song, Jae-Sang;Nah, Jung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate to effect of the electro-polishing condition according to electrolyte temperature and current and polishing time on surface morphology and composition by scanning electron microscopy(SEM) and energy dispersive X-ray spectrometer(EDS) in dental casting Co-Cr-Mo alloys. Methods: 16 specimens were divided into 4 groups which have each 4 specimens. The size of specimens were 10mm wide and 5mm height. the electro-polishing of specimens are by polishing solution temperature and times in Co-Cr-Mo alloy by SEM and EDS analysis. Results: The results shows that most smooth surface is obtained when electro-polishing is performed at $49^{\circ}C$ for 30-40sec with electro gap of 10mm and 8 voltage. Conclusion: The morphologies of specimens after electro-polishing were scratch absent and significant between at $40^{\circ}C$ for 45sec and at $49^{\circ}C$ for 45sec.

Fabrication of Two-dimensional Photonic Crystal by Roll-to-Roll Nanoreplication (롤투롤 나노 복제 공정을 이용한 이차원 광결정 소자의 제작)

  • Kim, Young-Kyu;Byeon, Euihyeon;Jang, Ho-Young;Kim, Seok-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.16-22
    • /
    • 2013
  • A two-dimensional photonic crystal structure was investigated using a roll-to-roll nanoreplication and physical vapor deposition processes for the inexpensive enhanced fluorescence substrate which is not sensitive to the polarization directions of excitation light source. An 8 inch silicon master having nano dot array with a diameter of 200 nm, a height of 100 nm and a pitch of 400 nm was prepared by KrF laser scanning lithography and reactive ion etching processes. A flexible polymer mold was fabricated by flat type UV replication process and a deposition of 10 nm nickel layer as an anti-adhesion layer. A roll mold was prepared by warping the flexible polymer mold on an aluminum roll base and a roll-to-roll UV replication process was carried out using the roll mold. After the deposition of ~ 100 nm $TiO_2$ layer on the replicated nano dot array, a 2 dimensional photonic crystal structure was realized with a resonance wavelength of 635 nm for both p- and s-polarized light sources.

Fabrication of Blended PCL/β-TCP Scaffolds by Mixture Ratio of β-TCP using Polymer Deposition System (폴리머 적층 시스템을 이용한 β-TCP 혼합 비율에 따른 PCL/β-TCP 인공지지체의 제작)

  • Ha, Seong-Woo;Kim, Jong Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.791-797
    • /
    • 2014
  • Abstract Scaffold used as a carrier of the cell has been actively conducted using plenty of technology in tissue engineering. ${\beta}$-tricalcium phosphate (${\beta}$-TCP) material has shown good biocompatibility and osteoconductive ability when it was implanted as a bone graft substitute in osseous defect in human and animal studies for bone regeneration. In this study, we fabricated the blended polycaprolactone (PCL) and ${\beta}$-TCP scaffold by the polymer deposition system (PDS). The PCL/${\beta}$-TCP scaffold was fabricated at a temperature of $110^{\circ}C$, pressure of 650 kPa, and scan velocity of 100 mm/sec. The Overall geometry and size of the scaffold were fixed circle type with a diameter of 10 mm and a height of 4 mm. PCL/${\beta}$-TCP scaffold was observed by scanning electron microscopy. Cell attachment and proliferation of the scaffold containing 30 wt% ${\beta}$-TCP was superior to those containing 10 wt% and 20 wt% ${\beta}$-TCP.

Changes in Soluble Protein, Free Amino Acid and Starch of Jeungpyun Dough during Fermentation (발효과정 중 증편반죽의 가용성 단백질, 유리아미노산 및 전분의 변화)

  • 박영선;서정식
    • Korean journal of food and cookery science
    • /
    • v.11 no.3
    • /
    • pp.282-286
    • /
    • 1995
  • Physicochemical properties of Jeungpyun dough were analyzed during fermentation in the ranges of 0 to 10 hours. Solube Protein and total content of free amino acid of Jeungpyun dough were decreased at the early stage of fermentation, recording minimum value, 0.292 mg/g-dry matter and 13.31 mg/100g-dry matter at fermentation time, 2 hours and 4 hours respectively while they were increased since then. It was observed that, although few changes occurred at the early stage of fermentation, the height of peak on X-ray diffractogram was decreased somewhat and some disintegration of starch granule on scanning electron micrograph occurred slightly in dough samples of above 6 hours of fermentation time.

  • PDF

Investigation of Oxygen Incorporation in AlGaN/GaN Heterostructures

  • Jang, Ho-Won;Baik, Jeong-Min;Lee, Jong-Lam;Shin, Hyun-Joon;Lee, Jung-Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.2
    • /
    • pp.96-101
    • /
    • 2003
  • Direct evidence on the incorporation of high concentration of oxygen into undoped AlGaN layers for the AlGaN/GaN heterostuctures is provided by scanning photoemission microscopy using synchrotron radiation. In-situ annealing at $1000^{\circ}C$ resulted in a significant increase in the oxygen concentration at the AlGaN surface due to the predominant formation of Al-O bonds. The oxygen incorporation into the AlGaN layers resulting from the high reactivity of Al to oxygen can enhance the tunneling-assisted transport of electrons at the metal/AlGaN interface, leading to the reduction of the Schottky barrier height and the increase of the sheet carrier concentration near the AlGaN/GaN interface.

Design and Implementation of a Real-Time Vehicle's Model Recognition System (실시간 차종인식 시스템의 설계 및 구현)

  • Choi Tae-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.877-889
    • /
    • 2006
  • This paper introduces a simple but effective method for recognizing vehicle models corresponding to each maker by information and images for moving vehicles. The proposed approach is implemented by combination of the breadth detection mechanism using the vehicle's pressure, exact height detection by a laser scanning, and license plate recognition for classifying specific vehicles. The implemented system is therefore capable of robust classification with real-time vehicle's moving images and established sensors. Simulation results using the proposed method on synthetic data as well as real world images demonstrate that proposed method can maintain an excellent recognition rate for moving vehicle models because of image acquisition by 2-D CCD and various image processing algorithms.

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF

3D RECONSTRUCTION OF LANDSCAPE FEATURES USING LiDAR DATAAND DIGITAL AERIAL PHOTOGRAPH FOR 3D BASED VISIBILITY ANALYSIS

  • Song, Chul-Chul;Lee, Woo-Kyun;Jeong, Hoe-Seong;Lee, Kwan-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.548-551
    • /
    • 2007
  • Among components of digital topographic maps used officially in Korea, only contours have 3D values except buildings and trees that are demanded in landscape planning. This study presented a series of processes for 3Dreconstructing landscape features such as terrain, buildings and standing trees using LiDAR (Light Detection And Ranging) data and aerial digital photo graphs. The 3D reconstructing processes contain 1) building terrain model, 2) delineating outline of landscape features, 3) extracting height values, and 4) shaping and coloring landscape features using aerial photograph and 3-D virtual data base. LiDAR data and aerial photograph was taken in November 2006 for $50km^{2}$ area in Sorak National Park located in eastern part of Korea. The average scanning density of LiDAR pulse was 1.32 points per square meter, and the aerial photograph with RGB bands has $0.35m{\times}0.35m$ spatial resolution. Using reconstructed 3D landscape features, visibility with the growing trees with time and at different viewpoints was analyzed. Visible area from viewpoint could be effectively estimated considering 3D information of landscape features. This process could be applied for landscape planning like building scale with the consideration of surrounding landscape features.

  • PDF

Development of Nipkow Disk for High-Speed Confocal Probe Using Micro-lens and Pinhole Disks (마이크로 렌즈 디스크와 핀홀 디스크를 이용한 고속 공초점용 닙코 디스크 개발)

  • Kim, Gee Hong;Lee, Hyung Seok;Kim, Chang Kyu;Lim, Hyung Jun;Lee, Jae Jong;Choi, Kee Bong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.636-641
    • /
    • 2014
  • This paper discusses the fabrication process for a Nipkow disk using micro-lens and pinhole disks. The confocal measuring system that uses the Nipkow disk has the advantage in measuring speed, because the Nipkow disk can simultaneously provide confocal images of all pixels in a CCD camera without requiring a lateral scanning unit. A micro-lens configuration, which focuses illumination on a pinhole, overcomes the low optical efficiency of the Nipkow disk system and allows its use in practical applications. This paper describes how to design the Nipkow disk in terms of numerical aperture, particularly for measuring the height of solder bumps in packaging application and for hybrid processes combining mechanical and semiconductor processes.

Vibration Evaluation and Accuracy Improvement for a Digital Pile Rebounding and Penetration Monitoring System (DPRMS) (디지털 항타관리기(DPRMS)의 진동영향 평가 및 측정 정밀도 향상 방안에 관한 연구)

  • Hong, Jung-Taek;Lee, Kye-Young;Lee, Sang-Hun;Han, Song-Soo;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.514-520
    • /
    • 2006
  • In this study, the performance of a digital pile rebounding and penetration monitoring system (DPRMS) is evaluated and the measurement precision of the DPRMS is improved. The DPRMS is a high speed line-scanning camera system to measure the rebound and penetration of a pile in a construction work. A main problem in the DPRMS is a measurement error, which is caused by a shock or vibration due to a hammer impact. The measurement error is investigated by analyzing vibration signals of the DPRMS during the impact. Moreover, the frequency response functions of the DPRMS are also analyzed. As a result, it is found that the tripod height has an influence on the DPRMS performance and a shorter tripod is better. One more founding in this study is that the DPRMS should be placed with a appropriate distance from a pile for improving the measurement precision.