• 제목/요약/키워드: Scanning Sensor

검색결과 449건 처리시간 0.038초

단층 탄소나노튜브의 일산화질소 가스에 대한 감응특성과 열처리 효과 (NO Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect)

  • 김민주;윤광현;허증수
    • 센서학회지
    • /
    • 제13권4호
    • /
    • pp.292-297
    • /
    • 2004
  • Carbon nanotubes (CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in ${\alpha}$-Terpinol($C_{10}H_{17}OH$) solution. The CNT tilms were fabricated by screen printing method on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film was observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NO response and recovery time. The CNT sensor with a heater was compared to that without a heater. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

이중센서 위너필터를 이용한 디지탈 라디오 그라피 영상 복원 (Image Restoration in Digital Radiography Using Dual Sensor Wiener Filer)

  • Lee, Tae-Soo;Park, Kwang-Suk;Min, Byoumg-Goo;Lim, Jeong-Gee;Han, Man-Chung
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.293-302
    • /
    • 1989
  • A Dual Sensor Wiener Filter technique was used to improve the image quality of the scanning type digital radiographic system (resolution and SNR). In this method, two images were acquried simultaneously using two sensors with high and low resolution and SNR values. Using the cross Power spectrum between dual sensor outputs of the same chest radiographic image. we design a new type of Wiener Filter and implement it with fast algorithm. We compared the performance of this new dual sensor filter with conventional single sensor filters (Wiener Filter and Parametric Projec- tion Filter) . In simulation studies, it is shown that this new method has SNR improvement of 1-3 dB better than conventional filters.

  • PDF

레이져 변위센서를 이용한 용접선 자동추적에 관한 연구(2) (A Study on Automatic Seam Tracking of Arc Welding Using an Laser Displacement Sensor)

  • 양상민;조택동;전진환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.729-733
    • /
    • 1997
  • Due to the variety of disturbance, it is not ease to accomplish the in-process detection of weld line with non-contact sensor. To get around this difficulties problem develop an automatic seam tracking weld system, the reliable signal processing algorithm has been recommanded. In this research, laser displacement sensor is applied as a seam finder in the automatic tracking system. The sensor is controlled by a dc servo motor which is mounted at X-Y moving table. X-Y moving table manipulated by an ac servo motor controls the position and velocity of the welding torch. First, X-Y table moves to Y-axis to search the welding joint feature before starting the welding, and welding joint is from the scanning data and weighting factor for each other. Second, weld line is determined using proposed signal processing algorithm during welding process. Form the experimental results, we could see the possibility that laser displacement sensor with procesed algorithm can be used as a seam finder in welding process under the severe noise (spatter,arc light etc.) condition

  • PDF

The influence of nonlinear damping on the response of a piezoelectric cantilever sensor in a symmetric or asymmetric configuration

  • Habib, Giuseppe;Fainshtein, Emanuel;Wolf, Kai-Dietrich;Gottlieb, Oded
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.239-243
    • /
    • 2022
  • We investigate the influence of nonlinear viscoelastic damping on the response of a cantilever sensor covered by piezoelectric layers in a symmetric or asymmetric configuration. We formulate an initial-boundary-value problem which consistently incorporates both geometric and material nonlinearities including the effect of viscoelastic damping which cannot be ignored for micro- and nano-mechanical sensor operation in a vacuum environment. We employ an asymptotic multiple-scales methodology to yield the system nonlinear frequency response near its primary resonance and employ a model-based estimation procedure to deduce the system damping backone curve from controlled experiments in vacuum. We discuss the effect of nonlinear damping on sensor applications for scanning probe microscopy.

Development and Evaluation of Non-Hydrous Skin Analogue Liquid Crystal using Thermo-Sensitivity Smart Sensor

  • Yoo, Kwang-Ho;Hong, Jae-Hwa;Eun, So-Hee;Jeong, Tae-Hwa;Jeong, Kwan-Young
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.367-374
    • /
    • 2014
  • In this study, skin permeation enhancement was confirmed by designing it to have a structure and composition similarity to the intercellular lipids that improve miscibility with skin by cross-linked lipids poloxamer. The cross-linked lipids poloxamer was synthesized and analyzed by 1H NMR that structure dose had conjugated pluronic with ceramide3. Active component is released by modification of liquid crystal structure because PPO part, large-scale molecule block of pluronic, has hydrophobic nature at skin temperature of $35^{\circ}C$. Conjugated pluronic with ceramide3 was synthesized using Pluronic F127 and p-NPC (4-nitrophenyl chloroformate) at room temperature yielded 89%. Pluronic(Ceramide 3-conjugated Pluronic) was synthesized by reaction of p-NP-Pluronic with Ceramide3 and DMAP. The yield was 51%. This cross-linked lipids poloxamer was blended and dissolved at isotropic state with skin surface lipids, phospholipid, ceramide, cholesterol and anhydrous additive solvent. Next step was preceded by ${\alpha}$-Transition at low temperature for making the structure of Meso-Phase Lamella, and non-hydrous skin analogue liquid crystal using thermo-sensitivity smart sensor, lamellar liquid crystal structure through aging time. For confirmation of conjugation thermo-sensitivity smart sensor and non-hydrous skin analogue liquid crystal, structural observation and stability test were performed using XRD(Xray Diffraction), DSC(Differential Scanning Calorimetry), PM (Polarized Microscope) And C-SEM (Cryo-Scanning Electron Microscope). Thermo-sensitivity observation by Franz cell revealed that synthesized smart sensor shown skin permeation effect over 75% than normal liquid crystal. Furthermore, normal non-hydrous skin analogue liquid crystal that not applied smart sensor shown similar results below $35^{\circ}C$ of skin temperature, but its effects has increased more than 30% above $35^{\circ}C$.

유전 센서 및 광섬유 센서를 이용한 EMC 유효 경화 수축 측정 (Measurement of effective cure shrinkage of EMC using dielectric sensor and FBG sensor)

  • 백정현;박동운;김학성
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.83-87
    • /
    • 2022
  • 최근 반도체 패키지 두께가 점점 얇아짐에 따라 휨(warpage) 문제가 대두되고 있다. 휨(warpage)은 패키지 구성요소들 간의 물성 차이로 인해 발생하기 때문에, 휨(warpage)을 예측하기 위해서는 주된 구성요소인 EMC(Epoxy molding compound)의 정확한 물성 파악이 필수적으로 요구된다. 특히 EMC는 경화 공정 중 경화 수축을 보이는데, 겔점 이후에 발생하는 유효 경화 수축은 휨(warpage) 발생의 핵심 요소이다. 본 연구에서는 유전 센서를 이용해 측정한 소실 계수로부터 실제 반도체 패키지 경화 공정 동안 발생하는 EMC의 겔점이 정의되었다. 유전 센서로부터 얻은 결과를 분석하기 위해 DSC(Differential scanning calorimetry) 시험과 rheometer 시험이 수행되었다. 그 결과, 유전 측정법이 EMC 경화상태 모니터링에 효과적인 방법임이 검증되었다. 유전 측정과 동시에 광섬유 센서를 이용해 EMC의 경화 공정 중 변형률 변화 추이가 함께 측정되었다. 위 결과들로부터 경화 공정 중 발생하는 EMC의 유효 경화 수축이 측정되었다.

The realization of 3D Display by using 2D sensor

  • Lee, Kyu-Tae;Um, Kee-Tae;Kim, Sang-Jo;Chae, Kyung-Pil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.765-768
    • /
    • 2008
  • To make 3D camera system, we check the possibility of advanced range camera module based on measuring the time delay of modulated infrared light, using a single detector chip fabricated on standard CMOS process. To depth information, electronic shutter and interlaced scanning method of 2D sensor is needed. Especially, we design "lens system, illumination unit" and review simulation result.

  • PDF

소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량 (Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope)

  • 백범;이승민;윤주환;김정구
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF

CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구 (A Study on Graylevel Image Scanning System Realization Using CIS)

  • 김영빈;김윤호;류광렬
    • 한국정보통신학회논문지
    • /
    • 제6권3호
    • /
    • pp.470-474
    • /
    • 2002
  • 본 논문은 CIS를 이용한 문서의 전자문서화 또는 OMR, OCR 인식에 적합한 고속 스캐너스케닝시스템 설계 및 구현에 관한 연구이며 설계기법은 CIS스케닝 센서를 고정한 상태에서 스텝모터를 이용한 기구적 조사방식을 적용하였다. 최적화 시스템을 구현하기 위해 전용의 영상처리프로세서를 사용하였다. 센서를 통해 피딩 스텝단위의 라인 당 입력된 데이터는 시스템 메모리에 저장되고 스케닝 종료위치에 이르면 페이지 당 보관된 메모리의 데이터는 USB 인터페이스 방식을 이용하여 PC로 전송하도록 설계하였다. 구현된 시스템은 소형이며 최대 A4 사이즈의 이미지 스케닝이 가능하고 이미지 스캐닝 시스템 처리속도는 초당 300mm를 유지한다 인식률은 OCR과 바 코드에서 98%이다.

CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구 (A Study on Graylevel Image Scanning System Realization Using CIS)

  • 김영빈;김윤호;류광렬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.581-584
    • /
    • 2002
  • 본 논문은 CIS를 이용한 문서의 전자문서화 또는 OMR, OCR 인식에 적합한 고속 스캐너스케닝시스템 설계 및 구현에 관한 연구이며 설계기법은 CIS스케닝 센서를 고정한 상태에서 스텝모터를 이용한 기구적 조사방식을 적용하였다. 최적화 시스템을 구현하기 위해 전용의 영상처리프로세서를 사용하였다. 센서를 통해 피딩 스텝단위의 라인 당 입력된 데이터는 시스템 메모리에 저장되고 스케닝 종료위치에 이르면 페이지 당 보관된 메모리의 데이터는 USB 인터페이스 방식을 이용하여 PC로 전송하도록 설계하였다. 구현된 시스템은 소형이며 최대 A4 사이즈의 이미지 스케닝이 가능하고 이미지 스케닝 시스템 처리속도는 초당 300mm를 유지한다. 인식률은 OCR과 바 코드에서 98%이다.

  • PDF