• Title/Summary/Keyword: Scanned data

Search Result 478, Processing Time 0.036 seconds

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Permanent Preservation and Use of Historical Archives : Preservation Issues Digitization of Historical Collection (역사기록물(Archives)의 항구적인 보존화 이용 : 보존전략과 디지털정보화)

  • Lee, Sang-min
    • The Korean Journal of Archival Studies
    • /
    • no.1
    • /
    • pp.23-76
    • /
    • 2000
  • In this paper, I examined what have been researched and determined about preservation strategy and selection of preservation media in the western archival community. Archivists have primarily been concerned with 'preservation' and 'use' of archival materials worth of being preserved permanently. In the new information era, preservation and use of archival materials were faced with new challenge. Life expectancy of paper records was shortened due to acidification and brittleness of the modem papers. Also emergence of information technology affects the traditional way of preservation and use of archival materials. User expectations are becoming so high technology-oriented and so complicated as to make archivists act like information managers using computer technology rather than traditional archival handicraft. Preservation strategy plays an important role in archival management as well as information management. For a cost-effective management of archives and archival institutions, preservation strategy is a must. The preservation strategy encompasses all aspects of archival preservation process and practices, from selection of archives, appraisal, inventorying, arrangement, description, conservation, microfilming or digitization, archival buildings, and access service. Those archival functions should be considered in their relations to each other to ensure proper preservation of archival materials. In the integrated preservation strategy, 'preservation' and 'use' should be combined and fulfilled without sacrificing the other. Preservation strategy planning is essential to determine the policies of archives to preserve their holdings safe and provide people with a maximum access in most effective ways. Preservation microfilming is to ensure permanent preservation of information held in important archival materials. To do this, a detailed standardization has been developed to guarantee the permanence of microfilm as well as its product quality. Silver gelatin film can last up to 500 years in the optimum storage environment and the most viable option for permanent preservation media. ISO and ANIS developed such standards for the quality of microfilms and microfilming technology. Preservation microfilming guidelines was also developed to ensure effective archival management and picture quality of microfilms. It is essential to assess the need of preservation microfilming. Limit in resources always put a restraint on preservation management. Appraisal (and selection) of what to be preserved was the most important part of preservation microfilming. In addition, microfilms with standard quality can be scanned to produce quality digital images for instant use through internet. As information technology develops, archivists began to utilize information technology to make preservation easier and more economical, and to promote use of archival materials through computer communication network. Digitization was introduced to provide easy and universal access to unique archives, and its large capacity of preserving archival data seems very promising. However, digitization, i.e., transferring images of records to electronic codes, still, needs to be standardized. Digitized data are electronic records, and st present electronic records are very unstable and not to be preserved permanently. Digital media including optical disks materials have not been proved as reliable media for permanent preservation. Due to their chemical coating and physical character using light, they are not stable and can be preserved at best 100 years in the optimum storage environment. Most CD-R can last only 20 years. Furthermore, obsolescence of hardware and software makes hard to reproduce digital images made from earlier versions. Even if when reformatting is possible, the cost of refreshing or upgrading of digital images is very expensive and the very process has to be done at least every five to ten years. No standard for this obsolescence of hardware and software has come into being yet. In short, digital permanence is not a fact, but remains to be uncertain possibility. Archivists must consider in their preservation planning both risk of introducing new technology and promising possibility of new technology at the same time. In planning digitization of historical materials, archivists should incorporate planning for maintaining digitized images and reformatting them in the coming generations of new applications. Without the comprehensive planning, future use of the expensive digital images will become unavailable. And that is a loss of information, and a final failure of both 'preservation' and 'use' of archival materials. As peter Adelstein said, it is wise to be conservative when considerations of conservations are involved.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.