Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator |
Kim, Joong-Hyun
(Department of Nuclear Medicine, Seoul National University College of Medicine)
Lee, Jae-Sung (Department of Nuclear Medicine, Seoul National University College of Medicine) Kim, Jin-Su (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Byeong-Il (Department of Nuclear Medicine, Seoul National University College of Medicine) Kim, Soo-Mee (Department of Nuclear Medicine, Seoul National University College of Medicine) Choung, In-Soon (Department of Nuclear Medicine, Seoul National University College of Medicine) Kim, Yu-Kyeong (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Won-Woo (Department of Nuclear Medicine, Seoul National University College of Medicine) Kim, Sang-Eun (Department of Nuclear Medicine, Seoul National University College of Medicine) Chung, June-Key (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Myung-Chul (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Dong-Soo (Department of Nuclear Medicine, Seoul National University College of Medicine) |
1 | Kim YH, Lee DS, Kang JH, Lee YJ, Chung JK, Roh JK, et al. Reversing the silencing of reporter sodium/iodide symporter transgene for stem cell tracking. J Nucl Med 2005;46:305-11 |
2 | So MK, Kang JH, Chung JK, Lee YJ, Shin JH, Kim KI, et al. In vivo imaging of retinoic acid receptor activity using a sodium/iodide symporter and luciferase dual imaging reporter gene. Mol Imaging 2004;3:163-71 DOI ScienceOn |
3 | Kim JH, Lee JS, Kim JS, Lee BI, Kim SM, Lee WW, et al. Performance evlution of an animal SPECT system using Phillips ARGUS scintillation camera and pinhole collimator. J Nucl Med 2005;46[suppl]:250 [abstract] |
4 | Bai C, Shao L, Ye J, DurbinM. The Effects of Center of Rotation Errors on Cardiac SPECT Imaging. IEEE Trans Nucl Sci 2003;50:1528-35 DOI ScienceOn |
5 | Li J, Jaszczak RJ, Greer KL, Coleman RE. A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation. Phys Med Biol 1994;39:165-176 DOI ScienceOn |
6 | Kim KI, Chung JK, Kang JH, Lee YJ, Shin JH, Oh HJ, et al. Visualization of endogenous p53-mediated transcription in vivo using sodium iodide symporter. Clin Cancer Res 2005;11:123-8 PUBMED |
7 | Cherry SR, Shao Y, Silverman RW, Meadors K, Siegel S, Chatziioannou A, et al. MicroPET: a high resolution PET scanner for imaging small animals. IEEE Trans Nucl Sci 1997;44:1161-6 DOI ScienceOn |
8 | MacDonald LR, Patt BE, Iwanczyk JS, Tsui BMW, Wang Y, Frey EC et al. Pinhole SPECT of mice using the LumaGEM gamma camera. IEEE Trans Nucl Sci 2001;48:830-6 DOI ScienceOn |
9 | Smith MF, Jaszczak RJ. An analytic model of pinhole aperture penetration for 3D pinhole SPECT image reconstruction. Phys Med Biol 1998;43:761-775 DOI ScienceOn |
10 | Missimer J, Maldi Z, Honer M, Keller C, Schubiger A, Ametamey S-M. Performance evaluation of the 16-module quad-HIDAC small animal PET camera. Phys Med Biol 2004;49:2069-81 DOI ScienceOn |
11 | Shin JH, Chung JK, Kang JH, Lee YJ, Kim KI, So Y, et al. Noninvasive imaging for monitoring of viable cancer cells using a dual-imaging reporter gene. J Nucl Med 2004;45:2109-15 |
12 | Beekman FJ, van der Have F, Vastenhouw B, van der Linden AJ, van Rijk PP, Burbach JP, et al. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice. J Nucl Med 2005;46:1194-200 PUBMED |
13 | Tai C, Chatziioannou A, Siegel S, Young J, Newport D, Goble RN, et al. Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. Phys Med Biol 2001;46:1845-1862 DOI ScienceOn |
14 | Vanhove C, Defrise M, Franken PR, Everaert H, Deconinck F, Bossuyt A. Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study. Eur J Nucl Med 2000;27:140-6 DOI ScienceOn |
15 | National Electrical Manufacturers Association: NEMA standards publication NU1-2001: performance measurements of scintillation cameras. Rosslyn, VA, National Electrical Manufacturers Association, 2001 |
16 | Wu MC, Gao DW, Sievers RE, Lee RJ, Hasegawa BH, Dae MW. Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice. J Am Coll Cardiol 2003;42:576-82 DOI ScienceOn |
17 | Wu MC, Hasegawa BH, Dae MW. Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice. Med Phys 2000;29:2830-9 |
18 | Knoess C, Siegel S, Smith A, Newport D, Richerzhagen N, Winkeler A, et al. Performance evaluation of the microPET R4 PET scanner for rodents. Eur J Nucl Med Mol Imaging 2003 May;30:737-47 DOI PUBMED ScienceOn |