• 제목/요약/키워드: Scan-based test

검색결과 208건 처리시간 0.029초

Hybrid Test Data Transportation Scheme for Advanced NoC-Based SoCs

  • Ansari, M. Adil;Kim, Dooyoung;Jung, Jihun;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권1호
    • /
    • pp.85-95
    • /
    • 2015
  • Network-on-chip (NoC) has evolved to overcome the issues of traditional bus-based on-chip interconnect. In NoC-reuse as TAM, the test schedulers are constrained with the topological position of cores and test access points, which may negatively affect the test time. This paper presents a scalable hybrid test data transportation scheme that allows to simultaneously test multiple heterogeneous cores of NoC-based SoCs, while reusing NoC as TAM. In the proposed test scheme, single test stimuli set of multiple CUTs is embedded into each flit of the test stimuli packets and those packets are multicast to the targeted CUTs. However, the test response packets of each CUT are unicast towards the tester. To reduce network load, a flit is filled with maximum possible test response sets before unicasting towards the tester. With the aid of Verilog and analytical simulations, the proposed scheme is proved effective and the results are compared with some recent techniques.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

다중 시스템 클럭으로 동작하는 보드 및 SoC의 연결선 지연 고장 테스트 (Interconnect Delay Fault Test in Boards and SoCs with Multiple System Clocks)

  • 이현빈;김영훈;박성주;박창원
    • 대한전자공학회논문지SD
    • /
    • 제43권1호
    • /
    • pp.37-44
    • /
    • 2006
  • 본 논문은, IEEE 1149.1 및 IEEE P1500 기반의 보드 및 SoC의 연결선 지연 고장 테스트를 위한 회로 및 테스트 방법을 제안한다. IDFT 모드 시, 출력 셀의 Update와 입력 셀의 Capture가 한 시스템 클럭 간격 내에 이루어지도록 하는 시스템 클럭 상승 모서리 발생기를 구현한다. 이 회로를 이용함으로써, 단일 시스템 클럭 뿐만 아니라 다중 시스템 클럭을 사용하는 보드 및 SoC의 여러 연결선의 지연 고장 테스트를 쉽게 할 수 있다. 기존의 방식에 비해 면적 오버헤드가 적고 경계 셀 및 TAP의 수정이 필요 없으며, 테스트 절차도 간단하다는 장점을 가진다.

음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구 (Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements)

  • 옹장우;문순일;정현조
    • 비파괴검사학회지
    • /
    • 제13권3호
    • /
    • pp.7-13
    • /
    • 1993
  • AISI 4130 금속재를 사용한 균열 컴팩터 인장시편의 파괴거동이 음향방출(AE) 및 초음파 C-scan을 이용하여 조사되었다. 모든 시편들을 특정 수준의 하중까지 증가시키면서, 크랙 개구변위 (COD)와 더불어 여러가지의 음향방출 인자들을 얻었다. 크랙 선단의 크랙 개구변위와 손상(소성)역을 계산하기 위하여 탄소성 유한요소 해석이 수행되었다. 펄스-반사, 침수형으로한 초음파 C-scan은 손상역 크기와 상사시키기 위하여 행해졌다. 유한요소 해석 결과와 측정된 크랙개구변위는 만족할 정도로 일치하였다. 음향방출 결과에서, 시험시편들은 연성거동을 나타내었다. 총 사상수대 크랙 개구변위의 기울기는 크랙 개시점을 결정하는 데에 유용하였다. 예비 시험적인 C-scan 화상은 손상역의 초음파 진폭변화를 보여주었고, 손상역의 형상 및 크기가 유한요소 결과와 정성적으로 부합되었다. 손상역 크기에 관한 추가적인 연구가 요약되었다.

  • PDF

미국 여성의 3차원 바디 스캔 이미지 분석을 통한 상반신 측면체형 분류 (Classification of Side Somatotype of Upper Lateral Torso Analyzing 3D Body Scan Image of American Females)

  • 나현신
    • 복식
    • /
    • 제57권4호
    • /
    • pp.9-17
    • /
    • 2007
  • Somatotype is human body shape and physique type which can be classified not only by the size, but also by the shape or posture of the body. Postural variations in the alignment of the back, shoulder, and neck can have an adverse effect on the fit of garments designed to hang from the shoulders. There have been some previous studies about the lateral upper torso by analyzing photographic measurements. In this study, 3D body scan images were used to classify the side somatotype of upper lateral method even though they are major data in the classification of upper torso. This study focused on following objective.; 1) To apply new and developing technology into the apparel industry analyzing 3D body scan images. 2) To classify upper laterla torso using the data through the new improver technology, 3D body scanner. 3) To propose basic materials for well fitted garments for each type of figure. The test subjects for this study were two hundreds nine female aged 19 years and up who were recruited in Cornell university body scan research team. Seventeen Variables(12 angles, 5 lengths) out of 3D body scan data were measured based on these landmarks and applied to analyze. The result of factor analysis indicated that 6 factors were extracted through factor analysis and orthogonal rotation by the method of Varimax and those factors comprise 62.5% of total variance. And the somatotype of upper body is classified into 3 types of figures according to cluster analysis; Bent forward posture, Straight posture, Swayback posture. Future study could be addressed about the somatotype of body by the age group based on the large database with wide variety of age.

복합재 연소관의 초음파 결함 분석 프로그램 개발 (Development of Ultrasonic Defect Analysis Program for a Composite Motor Case)

  • 김동륜;임수용;정상기;이경훈
    • 한국추진공학회지
    • /
    • 제16권2호
    • /
    • pp.65-72
    • /
    • 2012
  • 초음파 결함 분석 프로그램은 초음파 반사법을 기반으로 초음파 신호처리 기법을 적용하여 개발되었고, FRP 층간분리 및 FRP/내열고무 미접착 결함을 정량적으로 측정할 수 있었다. 복합재 연소관에서 검출된 결함은 절단하여 전산화 단층촬영 및 영상 현미경으로 분석하였고, 결함 분석 프로그램의 결과와 일치하였다. 본 논문은 복합재 연소관의 초음파시험 데이터를 C-Scan 영상으로 변환하여 결함을 분석할 수 있는 프로그램 개발 과정을 기술하였다.

Grasshopper 프로그래밍 기반 3D 인체형상의 하반신 기준점 자동탐색 알고리즘 설계 (Development of an Algorithm for Automatic Extraction of Lower Body Landmarks Using Grasshopper Programming Language)

  • 유은주;송화경
    • 한국의류학회지
    • /
    • 제47권1호
    • /
    • pp.171-190
    • /
    • 2023
  • This study aims to develop algorithms for automatic extraction landmarks from the lower body of women aged 20-54 using the Grasshopper programming language, based on 3D scan data in the 8th SizeKorea dataset. First, 11 landmarks were defined using the morphological features of 3D body surfaces and clothing applications, from which automatic landmark extraction algorithms were developed. To verify the accuracy of the algorithm, this study developed an additional algorithm that could automatically measure 16 items, and algorithm-derived measurements and SizeKorea measurements were compared using paired t-test analysis. The statistical differences between the scan-derived measurements and the SizeKorea measurements were compared, with an allowable tolerance of ISO 20685-1:2018. This study found that the algorithm successfully identified most items except for the crotch point and gluteal fold point. In the case of landmarks with significant differences, the algorithms were modified. This study was significant because scan editing, landmark search, and measurement extraction were successfully performed in one interface, and the developed algorithm has a high efficiency and strong adaptability.

저전력 테스트를 고려한 효율적인 테스트 데이터 압축 방법 (An Efficient Test Data Compression/Decompression for Low Power Testing)

  • 전성훈;임정빈;김근배;안진호;강성호
    • 대한전자공학회논문지SD
    • /
    • 제42권2호
    • /
    • pp.73-82
    • /
    • 2005
  • 스캔 테스트를 위한 테스트 데이터의 양과 파워 소모는 SoC 테스트에서의 최근의 직면한 가장 큰 문제들이다. 따라서 본 논문에서는 저전력 테스트를 고려한 새로운 테스트 데이터 압축 방법을 제안한다. 제안하는 압축 방법은 테스트 데이터 압축을 위해 압축율, 전력 소모 감소율과 하드웨어 오버헤드를 고려하여 최대 효율을 가지도록 하는데 기초하고 있다. 압축율과 전력 감소율을 높이기 위해서 본 논문에서는 IR (Input Reduction) 기법과 MSCIR (Modified Statistical Code using Input Reduction) 압축 코드을 사용하며, 뿐만아니라 이를 위한 사전 작업인 새로운 스캔 플립플롭 순서 재조합 기법 및 테스트 패턴 순서 재조합 방법을 제안한다. 기존의 연구와는 달리 CSR 구조를 사용하지 않고 원래의 테스트 데이터 $T_D$를 사용하여 압축하는 방법을 사용한다. 이렇게 함으로써 제안하는 압축 방법은 기존의 연구에 비해 훨씬 높은 압축율을 가지며 낮은 하드웨어 오버헤드의 디컴프레션 구조와 적은 전력 소모를 가진다. ISCAS '89 벤치 회로에 대찬 기존의 연구와의 비교로서 그 결과를 알 수 있다.

SOC 테스트 시간 축소를 위한 새로운 내장 코어 기반 SOC 테스트 전략 (A New Test Technique of SOC Test Based on Embedded Cores for Reducing SOC Test Time)

  • 강길영;김근배;임정빈;전성훈;강성호
    • 대한전자공학회논문지SD
    • /
    • 제41권9호
    • /
    • pp.97-106
    • /
    • 2004
  • 본 논문에서는 내장 코어 기반 SOC의 테스트를 위한 새로운 테스트 전략을 제안한다. SOC 테스트는 전체 테스트 시간을 얼마나 줄일 수 있는가에 따라서 그 성능을 평가할 수 있다. SOC를 구성하는 코어에 대한 테스트 시간은 코어에 구성된 테스트 래퍼 구조에 의해서 결정되며, 테스트 래퍼는 TAM을 사용하기 때문에 결국 TAM에 할당되어 있는 스캔 체인의 길이에 의해서 결정된다. 따라서 SOC 설계 단계에서 테스트를 고려한 설계가 이뤄져야 하며 효율적인 테스트를 위해서는 테스트 전략을 잘 세워야 한다. 기존의 테스트 기법은 모두 SOC 전체 TAM 라인들을 몇 개의 그룹으로 나누고 코어에 할당된 스캔 체인들을 TAM 라인에 적절히 분배해서 코어의 테스트 시간과 SOC 전체의 테스트 시간을 모두 최소화 할 수 있는 구조를 만드는 방법이었다 하지만 이는 NP 문제로 모든 조합에 대한 시도를 통해서 최적의 곁과를 찾는 것이 불가능하다. 본 논문에서는 이 문제에 대한 새로운 방법을 제안하고 그 효율성을 증명한다.

게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가 (The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan)

  • 이동훈;유희재;이종훈;정우영
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF