• 제목/요약/키워드: Scan technique

검색결과 594건 처리시간 0.024초

Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구 (Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan)

  • 김정열;박훈희;남궁혁;조석원;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

ALOS-2 Stripmap-ScanSAR 위상간섭기법에서의 스펙트럼 분석 평가 (Evaluation on Spectral Analysis in ALOS-2 PALSAR-2 Stripmap-ScanSAR Interferometry)

  • 박서우;정성우;홍상훈
    • 대한원격탐사학회지
    • /
    • 제36권2_2호
    • /
    • pp.351-363
    • /
    • 2020
  • 연안 충적층 지역은 토양침식, 지반침하 등 지질 재해와 태풍, 홍수 해양 재해에 노출되어 인명 또는 재산 피해의 위험에 취약하다. 지반 침하는 지표 물질이 지하로 이동하면서 지반의 점진적인 또는 급격한 침강이 발생하는 현상으로 지속적인 감시가 요구된다. 영상레이더 위상간섭기법 (Radar Interferometry)은 마이크로파 영역에서 관측된 위상정보를 이용하여 지형 변위를 정밀하게 관측할 수 있는 기술이다. Small BAseline Subset(SBAS) 기법은 최소 20장 이상의 영상레이더 자료를 사용하여 대상 지역에 대한 시계열 지표 변위를 정밀하게 분석할 수 있어 지반침하 감시에 유용하다. X- 또는 C-밴드에 비해 장파장인 L-밴드 영상레이더 자료는 긴밀도 유지에 보다 유리하여 지구과학용으로 적합하다. 하지만 L-밴드 ALOS-2 PALSAR-2은 전지구 관측 프로그램을 운영하고 있어 시계열 분석을 하기에 영상 획득이 충분하지 않을 수 있다. 관심 지역인 부산의 경우, Stripmap 영상은 11장으로서 SBAS 시계열 분석 기법을 적용하기에는 부족한 촬영 수이다. 일반적으로 동일한 모드의 영상 간 위상간섭기법의 적용이 가능하지만, 비슷한 관측 기하에서 관측한 Stripmap과 ScanSAR 영상을 이용한 위상간섭기법의 적용이 성공적으로 수행된 바 있다. 해당 지역의 ScanSAR 영상은 18장으로 Stripmap-ScanSAR 위상간섭기법을 적용하면 SBAS 기법을 이용한 향상된 시계열 분석이 가능하게 된다. 본 연구에서는 Gamma 소프트웨어를 이용하여 ALOS-2 PALSAR-2로부터 획득된 L-band 영상 자료에 대한 위상간섭기법 적용 가능여부를 평가하였다. Stripmap-ScanSAR 위상간섭기법 적용을 위해 이종 모드 관측 영상 사이의 chirp bandwidth와 pulse repetition frequency (PRF)의 차이를 고려한 영상레이더 자료 처리를 수행하였으며, radar carrier frequency의 차이 보정과 common band filtering 적용 여부에 따라 발생하는 위상간섭도의 품질을 분석하였다. Radar carrier frequency 차이 보정에 따른 위상간섭도의 긴밀도 변화는 크게 나타나지 않았으나, common band filtering으로 인해, 위상간섭도에서 azimuth 방향으로 주기적인 잡음과 전체적인 긴밀도 저하가 발생하였다. 따라서 Stripmap-ScanSAR 위상간섭기법을 적용하는 경우 두 관측 모드의 range와 azimuth 방향의 밴드 폭의 특성에 따라 주의 깊은 자료 처리가 요구된다.

원자로 상부 헤드 관통관 TOFD 신호 시뮬레이션 (Simulation of Time of Flight Diffraction Signals for Reactor Vessel Head Penetrations)

  • 이태훈;김용식;이정석
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.273-280
    • /
    • 2016
  • 비파괴검사 분야에 대한 시뮬레이션은 다양한 결함에 대한 신호의 예측과 검사 절차 개발에 사용되어진다. 특히 비파괴검사 전용 시뮬레이션 툴인 CIVA는 정확도가 높고 빠른 계산이 가능하며, 비파괴평가 기술과 동일한 형태의 화면 표시와 시각적으로 개선된 3차원 그래픽 유저 인터페이스를 제공한다. CIVA 소프트웨어 개발자가 내부적으로 타당성 검증을 시행하겠지만, 사용 이전에 소프트웨어의 정확도를 평가하는 독립적인 유효성 검증 연구가 필요하다. 이러한 목적으로 이번 연구에서는 CIVA를 이용하여 원자로 상부 헤드 관통관 검사에 사용되는 보정시험편에 대하여 TOFD 신호를 시뮬레이션하고, 실제 검사 신호와 비교하여 시뮬레이션 신호의 정확도와 적용 범위에 대하여 검증하였다. 종합적으로, A-scan 신호, B-scan 이미지, 깊이 측정 측면에서 CIVA 시뮬레이션 결과와 실험 결과 간에 전반적으로 일치를 보였다.

의료 초음파 영상을 위한 화소단위 집속기법 (Display-Pixel-Based Focusing Method for Ultrasound Imaging)

  • 황재섭;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.419-431
    • /
    • 2000
  • 본 논문에서는 디지털 스캔 컨버터(DSC, digital scan converter)에 의한 왜곡이 근본적으로 발생하지 않는 새로운 초음파 영상 방법으로서 표시장치의 화소에 직접 수신 집속하는 기법(DPBF, display-pixel-based focusing)과 이를 구현하기 위한 초음파 영상 장치의 구조를 제안한다. 제안한 기법은 극 좌표에 위치하는 샘플링 점들 대신에 직각좌표상의 화소들에 직접 수신 집속 함으로써 DSC의 역할을 제거하였다. DPBF 기법을 적용한 영상에는 DSC에 의한 허상 및 구획화 현상 등이 나타나지 않으며, 일반적인 방법에 의한 영상에 비해 보다 세밀한 영상을 제공한다는 사실을 검증할 수 있었다. 본 논문은 DSC에 의한 보간 효과가 두 개의 비교 영상 A, B 간에 미치는 정도를 정량적으로 평가하기 위해서 영상거침 비(ICRA/B, Image Coarseness Ratio)를 새로운 성능 측정 방법으로 정의하였다. 이 ICRA/B를 이용하여 비교 영상간 거친 정도를 정량적으로 측정하였다.

  • PDF

인터레이스드 스캔방식 디지털 카메라의 떨림에 의한 영상블러 제거 (Deblurring of the Blurred Image Caused by the Vibration of the Interlaced Scan Type Digital Camera)

  • 전재춘
    • 한국측량학회지
    • /
    • 제23권2호
    • /
    • pp.165-175
    • /
    • 2005
  • 인터레이스 방식의 카메라가로부터 사진을 촬영시, 카메라가 움직인다면, 짝수와 홀수라인의 두 영상의 불인치인 블러가 발생한다. 본 논문은 인터레이스 방식의 카메라의 떨림에 의한 짝수와 홀수라인 영상간의 불일치를 제거하는 알고리즘을 제안하였다. 블러된 원 영상을 짝수라인과 홀수라인 영상으로 분리한다. 분리된 각 영상을 보간법을 이용하여 원 영상 크기의 영상을 생성한다. 만약 보간된 영상간의 큰 차이가 발생하면, 사진 촬영시 카메라가 움직인 경우이다 이 경우에는, 특징점 추출 및 정합, sub-pixel정합, 오류 정합된 광류제거, 영상모자이크를 통하여 불리된 두 영상으로부터 블러가 제거된 영상을 취득하는 것이다. 본 논문은 제안한 알고리즘이 카메라의 다양한 움직임의 영향으로 블러된 영상에서 선명한 영상을 생성 할 수 있음을 보였다.

수동형 Stainless Steel, Nickel-Titanium 및 엔진 구동형 Nickel-Titanium File의 근관형성 능력에 관한 비교 연구 (A STUDY ON COMPARISON OF STAINLESS STEEL, NICKEL-TITANIUM HAND, NICKEL-TITANIUM ENGINE-DRIVEN FILE INSTRUMENTATION USING COMPUTED TOMOGRAPHY)

  • 이황;임미경;이건일;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.391-400
    • /
    • 1998
  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교 (Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner)

  • 김부섭;김정호
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

Compressed sensing을 이용한 TOF MRA 검사에서 Flow rate와 CS factor의 변화에 따른 영향 (Effects of Flow Rates and CS Factors on TOF MRA using Compressed Sensing)

  • 김성호;정현근;유세종
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.281-291
    • /
    • 2021
  • 본 연구는 자기공명영상을 이용한 TOF MRA 검사에서 flow rate 2.0 ml 이하의 유속을 표현함에 있어 Compressed sensing의 사용에 따른 영상의 변화를 정량적으로 측정하고자 하였다. Auto-injector와 Flow phantom을 이용하여 각각의 혈류속도 구간을 설정하고 CS를 사용하지 않은 TOF without CS 기법과 CS를 이용한 TOF with CS 기법에서 CS factor의 변화에 따른 SNR, CNR, SSIM, RMSE 등을 측정하여 비교하였다. CS factor의 증가에 따라 나타나는 영상의 영향을 검증하고자 일원배치 분산분석(One-way ANOVA)을 시행하였다. 실험 결과 CS를 사용한 TOF MRA는 CS를 사용하지 않은 TOF MRA와 비교하여 SNR 및 CNR의 유의한 차이 없이 scan time이 현저하게 감소하였다. 반면 CS factor의 증가에 따라 SSIM 및 RMSE는 TOF without CS 영상과의 차이가 증가함을 나타내었다. 따라서 TOF MRA 검사 시 CS 기법을 통해 scan time을 효율적으로 감소시키되 적절한 CS factor의 범위를 충분히 고려해야 한다. 또한 CS factor와 영상의 유사도, 정밀성에 대한 지속적인 연구가 필요할 것으로 사료된다.

Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth

  • Ju Ri Ye;Yong Kwon Chae;Ko Eun Lee;Hyo-Seol Lee;Sung Chul Choi;Ok Hyung Nam
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner. Materials and Methods: The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value. Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05). Conclusion: Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.

테스팅 및 저전력을 고려한 최적화된 상태할당 기술 개발 (Development of Optimized State Assignment Technique for Testing and Low Power)

  • 조상욱;이현빈;박성주
    • 대한전자공학회논문지SD
    • /
    • 제41권1호
    • /
    • pp.81-90
    • /
    • 2004
  • 유한상태기의 상태할당은 이로부터 구현되는 순차회로의 속도, 면적, 테스팅 및 소비전력에 큰 영향을 미친다. 본 논문에서는 상태변수 그룹들 사이에 상호 의존성(dependency)을 최소화하여 테스팅 및 전력소모를 개선하기 위한 m-블록 분할을 이용한 새로운 상태할당 기술을 소개한다. m-블록 분할 알고리즘에 의해 상태도로부터 상태들을 그룹으로 나누어 상태변수의 상호의존성을 줄이고, 상태천이 확률에 의해 결정된 무게인자에 따라 상태간 상태변수의 변화를 최소로하는 코드를 할당하여 상태천이시 스위칭 횟수를 줄인다. 상태변수 의존성을 줄임으로써 순차회로 사이클이 줄어들어서 부분스캔 및 테스트 생성이 용이하게 되고, 상태변수간의 스위칭 횟수를 줄임으로써 소비전력이 줄어들게 든다. 즉, 본 상태할당 기술은 서로 상반 관계에 있는 테스팅과 저전력 문제를 동시에 해결할 수 있는 새로운 기술이다. 벤치마크 회로에 대한 실험결과 기존의 방법보다 고장점검도 및 소비전력이 현저히 개선되었음을 확인하였다.