• Title/Summary/Keyword: Scan method

Search Result 1,540, Processing Time 0.026 seconds

Nonlinear refractive index measurement for amorphous $As_2S_3$ thin film by Z-scan method (Z-scan 방법에 의한 비정질 $As_2S_3$ 박막의 비선형 굴절률 측정)

  • 김성규;이영락;곽종훈;최옥식;이윤우;송재봉;서호형;이일항
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.342-347
    • /
    • 1998
  • We present a theoretical analysis of Gaussian beam propagation in nonlinear Kerr media by using aberration-free approximation and Huygens-Fresnel diffraction integral and obtain a simple analytic formular for Z-scan characteristics. Z-scan experiments are carried out on amorphous $As_2S_3$ thin film and compared with the theory developed, showing good agreement. The sign and the value of ${\gamma}$ have been measured at 633 nm to be $+8.65{\times}10^{-6}\textrm{cm}^2/W$. We also measured the far-field intensity profiles, which confirm again self-focusing effect.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF

A Study on the Thermal Hydraulic Analysis and B-Scan Inspection for LDIE Degradation of Carbon Steel Piping in a Nuclear Plant (원전 탄소강 배관의 액적충돌침식 손상에 대한 B-Scan 검사 및 수치해석적 분석)

  • Hwang, Kyeong Mo;Lee, Dae Young
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.218-224
    • /
    • 2012
  • Liquid droplet impingement erosion (LDIE) known to be generated in aircraft and turbine blades is recently appeared in nuclear piping. UT thickness measurements with both A-scan and B-scan UT inspection equipments were performed for a component estimated as susceptible to LDIE in feedwater heater vent system. The thickness data measured with B-Scan equipment were compared with those of A-Scan. Thermal hydraulic analysis based on ANSYS FLUENT code was performed to analyze the behavior of liquid droplets inside piping. The wall thinning rate and residual lifetime based on both existing Sanchez-Caldera equation and measuring data were also calculated to identify the applicability of the existing equation to the LDIE management of nuclear piping. Because Sanchez-Caldera equation do not consider the feature of magnetite formed inside piping, droplet size, colliding frequency, the development of new evaluation method urgently needs to manage the pipe wall thinning caused by LDIE.

Synthesis of Human Body Shape for Given Body Sizes using 3D Body Scan Data (3차원 스캔 데이터를 이용하여 임의의 신체 치수에 대응하는 인체 형상 모델 생성 방법)

  • Jang, Tae-Ho;Baek, Seung-Yeob;Lee, Kun-Woo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.6
    • /
    • pp.364-373
    • /
    • 2009
  • In this paper, we suggest the method for constructing parameterized human body model which has any required body sizes from 3D scan data. Because of well developed 3D scan technology, we can get more detailed human body model data which allow to generate precise human model. In this field, there are a lot of research is performed with 3D scan data. But previous researches have some limitations to make human body model. They need too much time to perform hole-filling process or calculate parameterization of model. Even more they missed out verification process. To solve these problems, we used several methods. We first choose proper 125 3D scan data from 5th Korean body size survey of Size Korea according to age, height and weight. We also did post process, feature point setting, RBF interpolation and align, to parameterize human model. Then principal component analysis is adapted to the result of post processed data to obtain dominant shape parameters. These steps allow to reduce process time without loss of accuracy. Finally, we compare these results and statistical data of Size Korea to verify our parameterized human model.

Usefulness of Tc-99m MIBI Scan in the Postoperative Follow Up Of Well-Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과 관찰에서 Tc-99m MIBI 스캔과 다른 추적 지표들의 유용성 비교)

  • You, Kye-Hwa;Song, Jae-Soon;Shinn, Joon-Jae;Lee, Hyun-Kyung;Cha, Wang-Ki;Kim, Do-Min;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.356-364
    • /
    • 1997
  • To evaluate the clinical utility of Tc-99m MIBI scan in the detection of residual thyroid tissue or metastatic lesion in postoperative thyroid cancer patients, we compared Tc-99m MIBI scan with I-131 diagnostic and therapeutic scan in 30 postoperative well-differentiated thyroid cancer patients. Thyroglobulin levels of both on and off thyroid hormone medication and antithyroglobulin antibody were tested [Tg(on), Tg(off)]. Positive rates for I-131 diagnostic and Tc-99m MIBI scan were 81% and 68% respectively. Concordance between I-131 diagnostic and Tc-99m MIBI scan was observed in 15 cases; 12 positive and 3 negative respectively. Among the 6 cases with negative I-131 diagnostic scan and positive Tc-99m MIBI scan, 4 were Positive in the therapeutic I-131 scan We concluded that Tc-99m MIBI scan maybe a useful complementary modality to the currently established method of I-131 scan and serum thyroglobulin level in the detection of recurrent or metastatic thyroid cancer, especially in the case of negative I-131 diagnostic scan.

  • PDF

A Feasibility Study on the Application of Ultrasonic Method for Surface Crack Detection of SiC/SiC Composite Ceramics (SiC/SiC 복합재료 세라믹스 표면균열 탐지를 위한 초음파법 적용에 관한 기초연구)

  • Nam, Ki-Woo;Lee, Kun-Chan;Kohyama, Akira
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.479-484
    • /
    • 2009
  • Nondestructive evaluation(NDE) of ceramic matrix composites is essential for developing reliable ceramics for industrial applications. In the work, C-Scan image analysis has been used to characterize surface crack of SiC ceramics nondestructively. The possibility of detection of surface crack were carried out experimentally by two types of ultrasonic equipment of SDS-win and $\mu$-SDS, and three types of transducer of 25, 50 and 125 MHz. A surface micro-crack of ceramics was not detected by transducer of 25 MHz and 50 MHz. Though the focus method was detected dimly the crack by transducer of 125 MHz, the defocus method could detect the shape of diamond indenter. As a whole, the focus method and the defocus method came to the conclusion that micro crack have a good possibility for detection.

Diagnosis and Treatment of the Recurrent Thyroid Cancer (갑상선 재발암의 진단과 치료에 대한 고찰)

  • Kwon O-Gyoung;Park Sung-Gil;Oh Sung-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2000
  • Objectives: To demonstrate effective diagnostic method and proper management of recurrent thyroid cancer through to compare treatment and surveillance of $I^{131}$ scanning detected recurrence and clinically detected recurrence. Material and Methods: We retrospectively analyzed clinical information about 46 patients who has recurrent thyroid cancer of 298 patients who have been primarily operated due to thyroid cancer in PMC at the over 10 years between 1986 and 1995. We examine incidence of recurrence due to pathologic types, site of recurrence, disease free interval, detection method of recurrence, and also treatment and progression of recurrence. A patients in which the clinical examination was entirely negative and the $I^{131}$ scan demonstrated either a new area of $I^{131}$ uptake or an increased area of concentration, compared to the previous scan, was designated as a recurrence detected by $I^{131}$ scan only. Recurrences that were obviously by physical examination or chest x-ray, etc were considered clinically detected recurrence, regardless of the the results of the thyroid scan. Results: Mean of disease tree interval(DFI) is 36months. When mean DFI of $I^{131}$ scan detected recurrence is 28months, whereas mean DFI of clinically detected recurrence is 47months. In statiscal analysis, p-value is 0.043 as significantly. In progression of recurrent patient, NED is 28case, AWD is Sease, DOD is 13case. Among the 13case, scan detected recurrence is lease of 20 patients(5%), whereas clinically detected recurrence is l2case of 26 patient(46%). In statiscal analysis, p-value is 0.003 as significantly. Conclusion: Early detection of the recurrent thyroid cancer by $I^{131}$ scanning leads to good progress compare with detection by clinical examination. NED: No Evidence of Disease AWD : Alive With Disease DOD : Dead Of Disease DOC: Dead of Other Cause

  • PDF

Usefulness of Audio-visual Methods that is used to Customer to Help Smooth Public Prosecutor at CT Examination (CT Scan Positioning시 고객의 검사진행의 이해를 돕기 위한 시청각 자료의 유용성)

  • Ahn, Hyeong-Taek;Jeon, Jung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • It is to improve customer satisfaction measurement and CT Scan process without delay of examination time when is using Scan positioning time(Planning time) that time is happened always between research reactor CT examination to increase fear and examination satisfaction by the customer's comprehension tribe which get the latest contrast enhancement CT examination. Needs and interests that customer wants to compose visual and auditory Contents to be played to Scan positioning time did questionnaire about curiosity later before CT examination to 600 people for October - November 2 months of 2006 to customer whole that get CT examination on source. Data getting through questionnaire investigated examination comprehension and satisfaction through questionnaire after experiment Scan Positioning to 500 coming to help customers to be source CT examination for 3 months February December - 2007 year in 2006 manufacturing Voice and Visual announce media for reference. To customer who interest degree appeared, and answers preparatory audit from preparatory audit about curiosity of CT examination customer to order of examination time required(43%), contrast media side effect(26%), examination region(20%), breath(10%), etc..(1.5%) audio-visual materials in questionnaire that attain after do reclamation among examination age, sex, reception type of irrelatively in 91% of target increase of hailing degree and examination satisfaction appear. Searched that customer hailing and satisfaction are increased greatly when use of audio-visual materials in satisfaction result that use CT Positioning delay time. In experiment process, It took lacking part by method that use hearing in case of do not use sight as is unavoidable in subject position or old age. Through this, audio-visual materials could analogize that it is more useful method that use sight and hearing at the same time.

  • PDF

Re-evaluation on conversion system of BactoScan and BactoCount for raw milk in South Korea (국내 원유 세균수 검사장비 박토스캔 및 박토카운트의 보정식 재평가)

  • Kim, ESeul;Kim, Jin-Hwan;Byun, Yeong-Seob;Park, Dasom;Kim, Ha-Young;Yoon, Soon-Seek;Moon, Jin-San
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.1
    • /
    • pp.39-45
    • /
    • 2022
  • The total bacteria count is significantly important factor for hygienic quality in raw milk. BactoScan FMTM and BactoCount IBCTM are the automated instruments for the determination of the total bacterial count in raw milk. They have been used after calibration by standard plate count (SPC) method in South Korea since 2000. It is necessary to re-evaluate for total bacterial counter according to the improvement of milk quality and the change of milk quality grade. Therefore, this study was evaluated the conversion mode of the two machines by SPC method. We collected 921 bulk-tank milk samples throughout the concentration range of 1,000~1,000,000 CFU/mL from June 2020 to October 2021. As a result, when compared by the SPC value, there was a slight difference in total bacterial count in BactoScan below 10,000 CFU/mL and above 200,000 CFU/mL and in BactoCount above 100,000 CFU/mL, respectively. Therefore, the conversion factor for BactoScan and the conversion equation for BactoCount were newly adjusted based on SPC value, and then the correlation coefficients (R2) was 0.85 or higher. In addition, the correlation (R2) between BactoScan and BactoCount was 0.91, which means the results were high positive correlation. These results are expected to contribute to improving the accuracy of the automated instruments for determining of total bacterial count in raw milk.

Binary Connected-component Labeling with Block-based Labels and a Pixel-based Scan Mask (블록기반 라벨과 화소기반 스캔마스크를 이용한 이진 연결요소 라벨링)

  • Kim, Kyoil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.287-294
    • /
    • 2013
  • Binary connected-component labeling is widely used in the fields of the image processing and the computer vision. Many kinds of labeling techniques have been developed, and two-scan is known as the fastest method among them. Traditionally pixel-based scan masks have been used for the first stage of the two-scan. Recently, block-based labeling techniques were introduced by C. Grana et. al. and L. He et. al. They are faster than pixel-based labeling methods. In this paper, we propose a new binary connected-component labeling technique with block-based labels and a pixel-based scan mask. The experimental results with various images show that the proposed method is faster than the He's which is known as the fastest method currently. The amount of performance enhancement is averagely from 3.9% to 22.4% according to the sort of the images.