• Title/Summary/Keyword: Scan Method

Search Result 1,536, Processing Time 0.027 seconds

Data Reusable Search Scan Methods for Low Power motion Estimation (저전력 움직임 추정을 위한 데이터 재사용 스캔 방법)

  • Kim, Tae Sun;SunWoo, Myung Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.85-91
    • /
    • 2013
  • This paper proposes the data reusable search scan methods for full search and fast search to implement low power Motion Estimation (ME). The proposed Optimized Sub-region Partitioning (OSP) method which divide search region into several sub-region can reduce the number of the required Reconfigurable Register Array (RRA) by half compared to the existing smart snake scan method for the same data reusability. In addition, the proposed Center Biased Search Scan method (CBSS) for various fast search algorithms can improve the data reusability. The performance comparisons show that the proposed search scan methods can reduce the average redundant data loading about 26.9% and 16.1% compared with the existing rater scan and snake scan methods, respectively. Due to the reduction of memory accesses, the proposed search scan methods are quite suitable for low power and high performance ME implementation.

Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods (서로 다른 두 가지 스캔법을 이용하여 제작된 지르코니아 보철물의 적합도에 대한 비교)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • Purpose: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. Materials and methods: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. Results: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). Conclusion: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.

A Novel Image Encryption Using Calligraphy Based Scan Method and Random Number

  • Sivakumar, T;Venkatesan, R
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.6
    • /
    • pp.2317-2337
    • /
    • 2015
  • Cryptography provides an effective solution to secure the communication over public networks. The communication over public networks that includes electronic commerce, business and military services, necessitates the requirement of simple and robust encryption techniques. In this paper, a novel image encryption method which employs calligraphy based hybrid scan and random number is presented. The original image is scrambled by pixel position permutation with calligraphy based diagonal and novel calligraphy based scan patterns. The cipher image is obtained by XORing the scrambled image with random numbers. The suggested method resists statistical, differential, entropy, and noise attacks which have been demonstrated with a set of standard images.

A New Scan Chain Fault Simulation for Scan Chain Diagnosis

  • Chun, Sung-Hoon;Kim, Tae-Jin;Park, Eun-Sei;Kang, Sung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.221-228
    • /
    • 2007
  • In this paper, we propose a new symbolic simulation for scan chain diagnosis to solve the diagnosis resolution problem. The proposed scan chain fault simulation, called the SF-simulation, is able to analyze the effects caused by faulty scan cells in good scan chains. A new scan chain fault simulation is performed with a modified logic ATPG pattern. In this simulation, we consider the effect of errors caused by scan shifting in the faulty scan chain. Therefore, for scan chain diagnosis, we use the faulty information in good scan chains which are not contaminated by the faults while unloading scan out responses. The SF-simulation can tighten the size of the candidate list and achieve a high diagnosis resolution by analyzing fault effects of good scan chains, which are ignored by most previous works. Experimental results demonstrate the effectiveness of the proposed method.

Low Power Scan Testing and Test Data Compression for System-On-a-Chip (System-On-a-Chip(SOC)에 대한 효율적인 테스트 데이터 압축 및 저전력 스캔 테스트)

  • 정준모;정정화
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.12
    • /
    • pp.1045-1054
    • /
    • 2002
  • We present a new low power scan testing and test data compression mothod lot System-On-a-Chip (SOC). The don't cares in unspecified scan vectors are mapped to binary values for low Power and encoded by adaptive encoding method for higher compression. Also, the scan-in direction of scan vectors is determined for low power. Experimental results for full - scanned versions of ISCAS 89 benchmark circuits show that the proposed method has both low power and higher compression.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS (ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석)

  • Kim, Hohyun;Han, Sang-Beom;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.384-391
    • /
    • 2001
  • In this study, a new quantitative analytical method has been developed for the rapid determination of acylcarnitines and amino acids in human blood using electrospray ionization / tandem mass spectrometry (ESI-MS/MS). Acylarmitines and amino acids were analyzed by tandem mass spectrometry after conversion to their butylesters through treatment with 3N butanolic hydrogen chloride. Acylcrnitines were analyzed using precursor 85 ion scan and alanine, valine, leucine/isoleucine, methionine, phenylalanine, tyrosine, aspartic acid and glutamic acid were analyzed using neutral loss 102 scan, ornitine and citrulline were analyzed neutral loss 119 scan, glycine was analyzed using neutral loss 56 scan, arginine was analyzed using neutral loss 161 scan and argininosuccinic acid was analyzed product ion 459 scan. This method reduced sample preparation time compared to that with conventional amino acid analyzer and liquid chromatography, with high sensitivity and good reproducibility.

  • PDF

FPGA Implementation of Scan Conversion Unit using SIMD Architecture and Hierarchical Tile-based Traversing Method (계층적 타일기반 탐색기법과 SIMD 구조가 적용된 스캔변환회로의 FPGA 구현)

  • Ha, Chang-Soo;Choi, Byeong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2023-2030
    • /
    • 2010
  • In this paper, we present research results of developing high performance scan conversion unit and implementing it on FPGA chip. To increase performance of scan conversion unit, we propose an architecture of scan converter that is a SIMD architecture and uses tile-based traversing method. The proposed scan conversion unit can operate about 124Mhz clock frequency on Xilinx Vertex4 LX100 device. To verify the scan conversion unit, we also develop shader unit, texture mapping unit and $240{\times}320$ color TFT-LCD controller to display outputs of the scan conversion unit on TFT-LCD. Because the scan conversion unit implemented on FPGA has 311Mpixels/sec pixel rate, it is applicable to desktop pc's 3d graphics system as well as mobile 3d graphics system needing high pixel rates.

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF