• Title/Summary/Keyword: Scale-up facility

Search Result 104, Processing Time 0.019 seconds

Full-scale EFC Study on Oil Recovery and Reuse from Discharge Gas of Tenter Facility in Textile Industry (Full-scale EFC (Electric Fume Collector)를 활용한 텐타공정 배출가스 정화 및 오일 회수)

  • Hwang, Yeal-Soon;Park, Hee-Jae;Chung, Gu-Hoi;Kim, Duk-Hyun;Na, Byung-Ki
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.259-265
    • /
    • 2011
  • The textile industry is suffered from air pollution problems which must be resolved. In particular, white smoke and odor after the tenter process require abatement. The major air pollution problem in the textile industry occurs during the finishing stages, where various chemicals are used for coating the fabrics. Lubricating oils, plasticizers, and water repellent chemicals are the fabric treatment chemicals. The coated fabrics are cured by heating in tenter facility. In this process, most of air pollutants emitted into the air. White smoke is basically made up of tiny solid or liquid particles of VOCs less than one micron in size. The oil mist can be carried over long distance from their point of origin. The most effective method of removing odor from tenter process is to get rid of tiny oil mist at the emitted gas. For this reason, the full-scale EFC (Electric Fume Collector) of 700 CMM was tested for removing odorous substances emitted from tenter facility. As a result of this study, odor and white smoke can be eliminated effectively and quite large amounts of oil can be recovered.

A Meta-analysis of the Timed Up and Go test for Predicting Falls (낙상 위험 선별검사 Timed Up and Go test의 예측 타당도 메타분석)

  • Park, Seong-Hi;Lee, On-Seok
    • Quality Improvement in Health Care
    • /
    • v.22 no.2
    • /
    • pp.27-40
    • /
    • 2016
  • Purpose: Globally, falls are a major public health problem. The study aimed to evaluate the predictive validity of the Timed Up and Go test (TUGT) as a screening tool for fall risk. Methods: An electronic search was performed Medline, EMBASE, CINAHL, Cochran Library, KoreaMed and the National Digital Science Library and other databases, using the following keywords: 'fall', 'fall risk assessment', 'fall screening', 'mobility scale', and 'risk assessment tool'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Thirteen studies were analyzed using meta-analysis with MetaDisc 1.4. Results: The selected 13 studies reporting predictive validity of TUGT of fall risks were meta-analyzed with a sample size of 1004 with high methodological quality. Overall predictive validity of TGUT was as follows. The pooled sensitivity 0.72 (95% confidence interval [CI]: 0.67-0.77), pooled specificity 0.58 (95% CI: 0.54-0.63) and sROC AUC was 0.75 respectively. Heterogeneity among studies was a moderate level in sensitivity. Conclusion: The TGUT's predictive validity for fall risk is at a moderate level. Although there is a limit to interpret the results for heterogeneity between the literature, TGUT is an appropriate tool to apply to all patients at a potential risk of accidental fall in a hospital or long-term care facility.

A Study on the Work Breakdown Structure of Agricultural Facilities for Developing a Construction and Maintenance Information System -Focused on Vinyl house, Glass greenhouse, Cattle shed- (농촌시설물 시공 및 유지관리 정보화 시스템 구축을 위한 작업분류체계 구축에 관한 연구 -비닐하우스, 유리온실, 축사를 중심으로-)

  • Choi, Oh-Young;Kim, Tae-Hui;Kim, Jae-Yeob;Kim, Gwang-Hee;Choi, Eung-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.147-155
    • /
    • 2009
  • Recently, the scale and technical complexity of agricultural production has been growing. Therefore, agricultural facilities are being gradually diversified, expanded, and made more complex. To furnish Korea's agricultural industry with international competitiveness, it is thus necessary to introduce new management techniques. The PCM (procurement-construction-maintenance) information management system for agricultural facilities is established by setting up its WBS (work breakdown structure). In this study, the WBS of a facility such as facility, space, element, works, and resources is analyzed. Following this analysts, a WBS of an agricultural facility that is appropriate for the PCM information system of an agricultural facility, is proposed by deriving it from actual WBS.

Residents' Community Characteristics of a Rural Area with Active Community - Case Study of Hongdong, Chungcheongnam-do - (농촌 지역공동체 활성화지역 주민의 공동체특성 - 충남 홍동지역 사례연구 -)

  • Jung, JiIn;Park, KyoungOk
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.105-118
    • /
    • 2015
  • The purpose of this study was to give a suggestion for vitalizing rural area's community, with respect to the components of community; 'locality' and 'communality'. The survey was conducted at Hondong, Hodongseong-gun, Chungcheongnam-do, which was a representative area for active rural area community. For the survey, we interviewed an activist on the village in November $9^{th}$, 2014, and let 81 residents fill the questionnaires during March $7^{th}$ to $14^{th}$, 2015. Major findings were as follows. 1) As for the 'locality' factor, the motives of residents' immigration were influenced by the availability of facilities for agriculture education, living, and convenience in the area. Most of residents recognized that the area comprises their own community facility area and expanded area with concentrated facilities of 'li', minimal adminstration unit. It means that their usage pattern of community facilities influences their conceptions of the village. 2) As for the 'communality' factor, original residents and immigrant back-to-farm residents showed different pattern in communicating with neighbors and community facility usages. Residents communicated with neighbors by meeting up or using the concentrated facilities in Gatgol, and visited the Balmak library frequently. Residents' sense of belonging was high with mean 4.16 point of 5.0 in Likert scale.

A Study on the Maintenance Cost Estimation Model of the Apartment Housing (공동주택의 관리비 추정모델 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

ASSESSMENT OF A NEW DESIGN FOR A REACTOR CAVITY COOLING SYSTEM IN A VERY HIGH TEMPERATURE GAS-COOLED REACTOR

  • PARK GOON-CHERL;CHO YUN-JE;CHO HYOUNGKYU
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.45-60
    • /
    • 2006
  • Presently, the VHTGR (Very High Temperature Gas-cooled Reactor) is considered the most attractive candidate for a GEN-IV reactor to produce hydrogen, which will be a key resource for future energy production. A new concept for a reactor cavity cooling system (RCCS), a critical safety feature in the VHTGR, is proposed in the present study. The proposed RCCS consists of passive water pool and active air cooling systems. These are employed to overcome the poor cooling capability of the air-cooled RCCS and the complex cavity structures of the water-cooled RCCS. In order to estimate the licensibility of the proposed design, its performance and integrity were tested experimentally with a reduced-scale mock-up facility, as well as with a separate-effect test facility (SET) for the 1/4 water pool of the RCCS-SNU to examine the heat transfer and pressure drop and code capability. This paper presents the test results for SET and validation of MARS-GCR, a system code for the safety analysis of a HTGR. In addition, CFX5.7, a computational fluid dynamics code, was also used for the code-to-code benchmark of MARS-GCR. From the present experimental and numerical studies, the efficacy of MARS-GCR in application to determining the optimal design of complicated systems such as a RCCS and evaluation of their feasibility has been validated.

A Study on the Sanitary Piping System Plan When an Aged Public Housing is Remodeled (노후 공동주택의 위생설비 리모델링 계획방안에 관한 연구)

  • Han, Soo-Gon;Lee, Sang-Youp;Lee, Seung-Yeon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.569-574
    • /
    • 2008
  • Recently, the domestic remodeling market is increased in scale. This study is to develop the sanitary piping system which improves quality of life and facility performance when the aged public housing is remodeled. Above all, we found out three standard floor plans in bathrooms of the public housing. And then, the plan and section types of the sanitary piping system were developed for the on-floor piping, a construction cost of each section types was estimated to review the economical fact. Also, the field mock-up test was performed in the type of the pipe shaft with on-floor pit. In result, the developed sanitary piping system was available for the remodeling public housing without a great facility cost. Additionally, the sanitary pipe was replaced easily through the shaft and on-floor fit. And a noise was reduced to a lower unit when the water flowed down.

  • PDF

Taming of large diameter triaxial setup

  • Nair, Asha M.;Madhavi Latha, G.
    • Geomechanics and Engineering
    • /
    • v.4 no.4
    • /
    • pp.251-262
    • /
    • 2012
  • Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.

Drying and Storage Characteristics of Small Scale Accumulated / Stirred Storage and Drying Bin (소형 교반식 저장건조빈의 벼 건조 및 저장 특성)

  • Park, Jong-Won;Ning, Xiao Feng;Cha, Yeong-Ok;Kang, Tae-Hwan;Han, Chung-Su;Cho, Sung-Chan
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.195-203
    • /
    • 2011
  • Not only does the labor of manufacturers used most in the drying process after rice harvest, but it also is having huge influence in quality. Also, because drying storage of rice production around the whole country is scarce with original facility, it has become a very important matter that farms develop their own safe and high-quality facilities to store and dry rice. Therefore, this study developed a small scale accumulated storage and drying bin, assessed nalyzed drying properties, and conducted analysis of research on the property of quality when storing for a long time. As a result, the drying speed of the small scale accumulated storage and drying bin was adequate of 0.042%/hr and was shown that the experimental static pressure and theoretical static pressure corresponded. Also, it was shown that drying cost was up to about 6 times inexpensive that heated air drying. For the storage of the small scale accumulated storage and drying bin, average of moisture content was around 16.5 until early April and decreased to 15.7% in July. Inside storage was maintained to 12.13% until early April and slightly increased to 14% after May. It was shown that inside storage had higher hardness and rate of cracking than the small scale accumulated storage and drying bin by storage conditions and germination rate was shown a little higher when stored in the small scale accumulated storage and drying bin.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.