Browse > Article

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility  

Ryu, Sang-Hoon ((주)페스텍인터내셔날)
Yoo, Yong-Ho (한국건설기술연구원)
Rie, Dong-Ho (인천대학교 안전공학과)
Publication Information
Fire Science and Engineering / v.24, no.3, 2010 , pp. 58-65 More about this Journal
Abstract
The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.
Keywords
Heat release; Smoke production; Oxygen consumption Calorimeter; Smoke detector; Skyscraper;
Citations & Related Records
연도 인용수 순위
  • Reference
1 S.-H. Ryu, Y.-H. Yoo, and D.-H. Rie, "The Study of a Correlation between Heat Release and Smoke Production by using Oxygen Consumption Calorimeter up to 10 MW Facility", APSS, pp.75-78, JSSE (2009).
2 Chuanmei Jiao, Jun Zhang and Feng Zhang, "Combustion Behavior of Intumescent Flame Retardant Polypropylene Composites", J. of Fire Sci., Vol.26, pp.455-469(2008).   DOI   ScienceOn
3 KS F ISO 13784-1, "건축용 샌드위치 패널 구조에 대한 연소 성능 시험방법-제1부: 소규모실 시험" (2009).
4 NFPA 265, "Standard Method of Fire Tests for Evaluation Room Fire Growth Contribution of Textile Wall Coverings", US(1994).
5 EN 14390, "Fire Test-Large Scale Room Reference Test for Surface Products", CEN, Brussels(2007).
6 EN 13823, "Reaction to Fire Tests for Building Products-Building Products Excluding Floorings Exposed to the Thermal Attack by a Single Burning Item", Brussels, Belgium(2002).
7 Kevin McGrattan, Bryan Klein, Simo Hostikka and Jason Floyd, Fire Dynamics Simulator (Version 5) User's Guide, NIST(2008).
8 K.T. Paul, "Cone Calorimeter: Initial Experiences of Calibration and Use", Fire Safety Journal, Vol.22, No.1, pp.67-87(1994).   DOI   ScienceOn
9 W.K. Chow, "Assessment on Heat Release Rate of Furniture Foam Arrangement by a Cone Calorimeter", J. of Fire Sci., Vol.20, pp.319-328(2002).   DOI   ScienceOn
10 John H. Klote and James A. Milke, "Principles of Smoke Management", Ashrae(2002).
11 한국건설기술연구원, "지하공간 환경개 및 방재기술 연구사업 1차년도 보고서", pp.57-68(2005).
12 소방방재청 국가화재정보 시스템, 2008년 화재통계 연보.
13 Philip J. DiNenno, P.E., Dougal Drysdale, PhD., Craig L. Beyler, PhD., W. Douglas Walton, P.e., Richard L.P. Custer, John R. Hall, Jr., PhD., John M. Watts, Jr., PhD., "SFPE 방화공학 핸드북 제3판", 한국화재보험협회(2005).
14 James G. Quintiere, "Principle of Fire Behavior", Delmar Publishers(1997).
15 V. Babrauskas and S.J. Grayson, "Heat Release in Fires", Elsevier(1992).
16 "The SFPE Handbook of Fire Protection Engineering", Ver. Third Edition.