Full-scale EFC Study on Oil Recovery and Reuse from Discharge Gas of Tenter Facility in Textile Industry  

Hwang, Yeal-Soon (Department of Chemical Engineering, Chungbuk National University)
Park, Hee-Jae (Siheung Environmental Technology Development Center)
Chung, Gu-Hoi (Siheung Environmental Technology Development Center)
Kim, Duk-Hyun (Department of Chemical Engineering & Biotechnology, Korea Polytechnic University)
Na, Byung-Ki (Department of Chemical Engineering, Chungbuk National University)
Publication Information
Clean Technology / v.17, no.3, 2011 , pp. 259-265 More about this Journal
Abstract
The textile industry is suffered from air pollution problems which must be resolved. In particular, white smoke and odor after the tenter process require abatement. The major air pollution problem in the textile industry occurs during the finishing stages, where various chemicals are used for coating the fabrics. Lubricating oils, plasticizers, and water repellent chemicals are the fabric treatment chemicals. The coated fabrics are cured by heating in tenter facility. In this process, most of air pollutants emitted into the air. White smoke is basically made up of tiny solid or liquid particles of VOCs less than one micron in size. The oil mist can be carried over long distance from their point of origin. The most effective method of removing odor from tenter process is to get rid of tiny oil mist at the emitted gas. For this reason, the full-scale EFC (Electric Fume Collector) of 700 CMM was tested for removing odorous substances emitted from tenter facility. As a result of this study, odor and white smoke can be eliminated effectively and quite large amounts of oil can be recovered.
Keywords
Textile; Odor; Oil mist; Tenter Process; EFC;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim, M. G., "Identification of Individual Odor Characteristic and Odor-Active Compounds from a Dye Company," Korean J. Odor Res. Eng., 8(3), 144-150 (2009).
2 Yoo, E, C., and Kim, S, Y., "Study on the Improvement of Tenter Facility Occurred Frequent Odor Nuisance," Annual Report of Busan Metropolotan City Institute of Health & Environment, 15(1) 167-176, 2005.
3 Song, H. K., Choi, J. W., Lee, H., and Na, B. K., "Preparation of Synthesis Gas from Methane in a Capacitive rf Discharge," Clean Technology, 12(3), 138-144 (2006).
4 Kim, D. J., Nasonova, A., and Kim, K. S., "NO and $SO_2$ Removal by Dielectric Barrier Discharge-Photocatalysts Hybrid Process," Clean Technology, 13(2), 115-121 (2007).
5 Best Management Practices for Pollution Prevention in the Textile Industry, EPA, Office of Research and Development, 1995 ; ATMI, Comments on draft document, 1997.
6 Smith, B., "Source Reduction by New Equipment. Presented at Pollution Resource Reduction in Textile Wet Processing," Raleigh, NC (may 23-24), 1989.
7 Goodman, G. A., Porter, J. J., and Davis, Jr., C. H., "Volatile Organic Compound Source Testing and Emission Control," Clemson University Review of Industrial Management and Textile Science (January), 1980.
8 Zeller, M. V., "Instrumental Techniques for Analyzing Air Pollutants Generated in Textile Processing," Textile Horizons (January), 1975.