• Title/Summary/Keyword: Sampling Procedure

Search Result 416, Processing Time 0.022 seconds

Chorionic villus sampling

  • Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • v.11 no.2
    • /
    • pp.43-48
    • /
    • 2014
  • Chorionic villus sampling has gained importance as a tool for early cytogenetic diagnosis with a shift toward first trimester screening. First trimester screening using nuchal translucency and biomarkers is effective for screening. Chorionic villus sampling generally is performed at 10-12 weeks by either the transcervical or transabdominal approach. There are two methods of analysis; the direct method and the culture method. While the direct method may prevent maternal cell contamination, the culture method may be more representative of the true fetal karyotype. There is a concern for mosaicism which occurs in approximately 1% of cases, and mosaic results require genetic counseling and follow-up amniocentesis or fetal blood sampling. In terms of complications, procedure-related pregnancy loss rates may be the same as those for amniocentesis when undertaken in experienced centers. When the procedure is performed after 9 weeks gestation, the risk of limb reduction is not greater than the risk in the general population. At present, chorionic villus sampling is the gold standard method for early fetal karyotyping; however, we anticipate that improvements in noninvasive prenatal testing methods, such as cell free fetal DNA testing, will reduce the need for invasive procedures in the near future.

Comparison of Rigorous Design Procedure with Approximate Design Procedure for Variable Sampling Plans Indexed by Quality Loss

  • Ishii, Yoma;Arizono, Ikuo;Tomohiro, Ryosuke;Takemoto, Yasuhiko
    • Industrial Engineering and Management Systems
    • /
    • v.15 no.3
    • /
    • pp.231-238
    • /
    • 2016
  • Traditional acceptance sampling plans have focused on the proportion of nonconforming items as an attribute criterion for quality. In today's modern quality management under high quality production environments, the reduction of the deviation from a target value in a quality characteristic has become the most important purpose. In consequence, various inspection plans for the purpose of reducing the deviation from the target value in the quality characteristic have been investigated. In this case, a concept of the quality loss evaluated by the deviation from the target value has been accepted as the variable evaluation criterion of quality. Further, some quality measures based on the quality loss have been devised; e.g. the process loss and the process capability index. Then, as one of inspection plans based on the quality loss, the rigorous design procedure for the variable sampling plan having desired operating characteristics (VS-OC plan) indexed by the quality loss has been proposed by Yen and Chang in 2009. By the way, since the estimator of the quality loss obeys the non-central chi-square distribution, the rigorous design procedure for the VS-OC plan indexed by the quality loss is complicated. In particular, the rigorous design procedure for the VS-OC plan requires a large number of the repetitive and complicated numerical calculation about the non-central chi-square distribution. On the other hand, an approximate design procedure for the VS-OC plan has been proposed before the proposal of the above rigorous design procedure. The approximate design procedure for the VS-OC plan has been constructed by combining Patnaik approximation relating the non-central chi-square distribution to the central chi-square distribution and Wilson-Hilferty approximation relating the central chi-square distribution to the standard normal distribution. Then, the approximate design procedure has been devised as a convenient procedure without complicated and repetitive numerical calculations. In this study, through some comparisons between the rigorous and approximate design procedures, the applicability of the approximate design procedure has been confirmed.

An Accelerated Life Test Sampling Plan for Bulk Material (벌크재료 가속시험샘플링검사방식설계)

  • Kim Jong-Geol;Kim Dong-Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.04a
    • /
    • pp.411-419
    • /
    • 2006
  • This paper aims at designing an accelerated life test sampling plan for bulk material and showing its application for an arc-welded gas pipe. It is an integrated model of the accelerated life test procedure and bulk sampling procedure. The accelerated life tests were performed by the regulation, RSD 0005 of ATS at KITECH and bulk sampling was used for acceptance. Design parameters might be total sample size(segments and increments), stress level and so on. We focus on deciding the sample size by minimizing the asymptotic variance of test statistic as well as satisfying consumer's risk under Weibull life time distribution with primary information on shape parameter.

  • PDF

Double Sampling with Zero Acceptance Number for the First Sample

  • Bai, Do-Sun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.3 no.2
    • /
    • pp.99-106
    • /
    • 1977
  • A double sampling procedure with zero acceptance number for the first sample whose operating characteristic closely matches that of a given single sampling plan and whose combined sample size does not exceed that of the given single sampling plan is proposed. The proposed double sampling plans corresponding to the MIL-STD-105D plans are tabulated and it is found that their ASN's are considerably smaller than those of corresponding MIL-STD-105D single or double sampling plans.

  • PDF

A Batch Sequential Sampling Scheme for Estimating the Reliability of a Series/Parallel System

  • Enaya, T.;Rekab, L.;Tadj, L.
    • International Journal of Reliability and Applications
    • /
    • v.11 no.1
    • /
    • pp.17-22
    • /
    • 2010
  • It is desired to estimate the reliability of a system that has two subsystems connected in series where each subsystem has two components connected in parallel. A batch sequential sampling scheme is introduced. It is shown that the batch sequential sampling scheme is asymptotically optimal as the total number of units goes to infinity. Numerical comparisons indicate that the batch sequential sampling scheme performs better than the balanced sampling scheme and is nearly optimal.

  • PDF

Some Perspectives on Variance Estimation in Sampling with Probability Proportional to Size

  • Kim, Sun-Woong
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.05a
    • /
    • pp.233-238
    • /
    • 2005
  • S${\"{a}}$rndal (1996) and Knottnerus (2003) had a critical look at the well known variance estimator of Sen (1953) and Yates and Grundy (1953) in probability proportional to size sampling. In this paper, we point out that although their approaches can avoid the difficulties in variance estimation with respect to the joint probabilities, there exist the disadvantages in practice. Also, we describe a sampling procedure available in statistical software that are useful for the variance estimation.

  • PDF

A Sample Design for National Nutrition Servey (국민영양조사(國民營養調査)를 위한 표본설계(標本設計) 소고(小考))

  • Jun, Tae-Yoon;Chung, Kee-Hey
    • Journal of Nutrition and Health
    • /
    • v.17 no.3
    • /
    • pp.236-241
    • /
    • 1984
  • In order to make clear the relationship between sample design and sample survey in community, it was conducted research on sample design for National Nutrition Survey in 1983. In this paper it was tried to analize the data based on The Report of a Settled Population, 1981 conducted by National Bureau of Statistics Economic Planning Board. The sample was basically using stratified two-stage sampling with systematic sampling of Ban or Li as administrative unit. The population represents the whole nation excluding Jeju-do because of budget. The selection of sampling unit and sampling procedure was as follows. 1) Stratify the nation-wide area in 20 sections according to administrative districts. 2) Determine the sample size in each section according to equal proportional rate (1 / 8040) and to about 1,000 households in the sample. 3) Select the 25 sampling units by section according to households proportion. 4) Select the 10 households at random from each Ban or Li according to equal probability proportion as the final sampling unit. Using the procedure, it was sampled 1,000 households for National Nutrition Survey in 1983.

  • PDF

Robust Bayes and Empirical Bayes Analysis in Finite Population Sampling with Auxiliary Information

  • Kim, Dal-Ho
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.3
    • /
    • pp.331-348
    • /
    • 1998
  • In this paper, we have proposed some robust Bayes estimators using ML-II priors as well as certain empirical Bayes estimators in estimating the finite population mean in the presence of auxiliary information. These estimators are compared with the classical ratio estimator and a subjective Bayes estimator utilizing the auxiliary information in terms of "posterior robustness" and "procedure robustness" Also, we have addressed the issue of choice of sampling design from a robust Bayesian viewpoint.

  • PDF

A BAYESIAN ANALYSIS FOR PRODUCT OF POWERS OF POISSON RATES

  • KIM HEA-JUNG
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.2
    • /
    • pp.85-98
    • /
    • 2005
  • A Bayesian analysis for the product of different powers of k independent Poisson rates, written ${\theta}$, is developed. This is done by considering a prior for ${\theta}$ that satisfies the differential equation due to Tibshirani and induces a proper posterior distribution. The Gibbs sampling procedure utilizing the rejection method is suggested for the posterior inference of ${\theta}$. The procedure is straightforward to specify distributionally and to implement computationally, with output readily adapted for required inference summaries. A salient feature of the procedure is that it provides a unified method for inferencing ${\theta}$ with any type of powers, and hence it solves all the existing problems (in inferencing ${\theta}$) simultaneously in a completely satisfactory way, at least within the Bayesian framework. In two examples, practical applications of the procedure is described.

Comparison of two sampling intervals and three sampling intervals VSI charts for monitoring both means and variances

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.4
    • /
    • pp.997-1006
    • /
    • 2015
  • In industrial quality control, when engineers use VSI control procedure they should consider both required time to signal and switching behaviors together in the case of production process changed. Up to the present, many researchers have studied fixed sampling interval (FSI) chart and variable sampling interval (VSI) chart in the points of average number of samples to signal (ANSS) and average time to signal (ATS). However, ANSS and ATS do not provide any switching information between different sampling intervals of VSI schemes. In this study, performances of two sampling intervals VSI chart and three sampling intervals VSI chart are evaluated and compared. The numerical results show that ANSS and ATS values of two sampling intervals VSI chart and three sampling interval VSI chart are similar regardless the amount of shifts. However, the values of switching behaviors including ANSW are less efficient in three sampling intervals VSI charts than in two sampling intervals VSI chart.