• Title/Summary/Keyword: Sampling Device

Search Result 276, Processing Time 0.02 seconds

Design of Wideband RF Frequency Measurement System with EP2AGX FPGA (EP2AGX FPGA를 이용한 광대역 고주파신호의 주파수 측정장치 설계)

  • Lim, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.1-6
    • /
    • 2017
  • This paper presents the design of a frequency measurement device using ADC, EP2AGX FPGA and STM32 processor to accurately measure the frequency of a broadband high frequency signal. The ADC device used in this paper has a sampling frequency of 250 MSPS and a processing frequency bandwidth of 100 MHz. Due to its high sampling frequency, it is difficult to process in ordinary computers or processors, so we implemented the frequency measurement algorithm using the Altra EP2AGX FPGA. The measured frequency is sent to the direction detection controller in real time and fused with the phase signal to calculate the incident azimuth angle of the high frequency signal. The designed frequency measurement device is about 0.2 Mhz in frequency measurement error and 30% less than Anaren DFD-x, which is considered to contribute greatly to the design of radio monitoring and direction detection device.

Assessment of the Reliability of a Novel Self-sampling Device for Performing Cervical Sampling in Malaysia

  • Latiff, Latiffah A.;Rahman, Sabariah Abdul;Wee, Wong Yong;Dashti, Sareh;Asri, Andi Anggeriana Andi;Unit, Nor Hafeeza;Li, Shirliey Foo Siah;Esfehani, Ali Jafarzadeh;Ahmad, Salwana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.559-564
    • /
    • 2015
  • Background: The participation of women in cervical cancer screening in Malaysia is low. Self-sampling might be able to overcome this problem. The aim of this study was to assess the reliability of self-sampling for cervical smear in our country. Materials and Methods: This cross-sectional study was conducted on 258 community dwelling women from urban and rural settings who participated in health campaigns. In order to reduce the sampling bias, half of the study population performed the self-sampling prior to the physician sampling while the other half performed the self-sampling after the physician sampling, randomly. Acquired samples were assessed for cytological changes as well as HPV DNA detection. Results: The mean age of the subjects was $40.4{\pm}11.3years$. The prevalence of abnormal cervical changes was 2.7%. High risk and low risk HPV genotypes were found in 4.0% and 2.7% of the subjects, respectively. A substantial agreement was observed between self-sampling and the physician obtained sampling in cytological diagnosis (k=0.62, 95%CI=0.50, 0.74), micro-organism detection (k=0.77, 95%CI=0.66, 0.88) and detection of hormonal status (k=0.75, 95%CI=0.65, 0.85) as well as detection of high risk (k=0.77, 95%CI=0.4, 0.98) and low risk (K=0.77, 95%CI=0.50, 0.92) HPV. Menopausal state was found to be related with 8.39 times more adequate cell specimens for cytology but 0.13 times less adequate cell specimens for virological assessment. Conclusions: This study revealed that self-sampling has a good agreement with physician sampling in detecting HPV genotypes. Self-sampling can serve as a tool in HPV screening while it may be useful in detecting cytological abnormalities in Malaysia.

Expanded Exit-Pupil Holographic Head-Mounted Display With High-Speed Digital Micromirror Device

  • Kim, Mugeon;Lim, Sungjin;Choi, Geunseop;Kim, Youngmin;Kim, Hwi;Hahn, Joonku
    • ETRI Journal
    • /
    • v.40 no.3
    • /
    • pp.366-375
    • /
    • 2018
  • Recently, techniques involving head-mounted displays (HMDs) have attracted much attention from academia and industry owing to the increased demand for virtual reality and augmented reality applications. Because HMDs are positioned near to users' eyes, it is important to solve the accommodation-vergence conflict problem to prevent dizziness. Therefore, holography is considered ideal for implementing HMDs. However, within the Nyquist region, the accommodation effect is limited by the space-bandwidth-product of the signal, which is determined by the sampling number of spatial light modulators. In addition, information about the angular spectrum is duplicated over the Fourier domain, and it is necessary to filter out the redundancy. The size of the exit-pupil of the HMD is limited by the Nyquist sampling theory. We newly propose a holographic HMD with an expanded exit-pupil over the Nyquist region by using the time-multiplexing method, and the accommodation effect is enhanced. We realize time-multiplexing by synchronizing a high-speed digital micromirror device and a liquid-crystal shutter array. We also demonstrate the accommodation effect experimentally.

A Digital Readout IC with Digital Offset Canceller for Capacitive Sensors

  • Lim, Dong-Hyuk;Lee, Sang-Yoon;Choi, Woo-Seok;Park, Jun-Eun;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.278-285
    • /
    • 2012
  • A digital readout IC for capacitive sensors is presented. Digital capacitance readout circuits suffer from static capacitance of sensors, especially single-ended sensors, and require large passive elements to cancel such DC offset signal. For this reason, to maximize a dynamic range with a small die area, the proposed circuit features digital filters having a coarse and fine compensation steps. Moreover, by employing switched-capacitor circuit for the front-end, correlated double sampling (CDS) technique can be adopted to minimize low-frequency device noise. The proposed circuit targeted 8-kHz signal bandwidth and oversampling ratio (OSR) of 64, thus a $3^{rd}$-order ${\Delta}{\Sigma}$ modulator operating at 1 MH was used for pulse-density-modulated (PDM) output. The proposed IC was designed in a 0.18-${\mu}m$ CMOS mixed-mode process, and occupied $0.86{\times}1.33mm^2$. The measurement results shows suppressed DC power under about -30 dBFS with minimized device flicker noise.

Estimating Illumination Distribution to Generate Realistic Shadows in Augmented Reality

  • Eem, Changkyoung;Kim, Iksu;Jung, Yeongseok;Hong, Hyunki
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.6
    • /
    • pp.2289-2301
    • /
    • 2015
  • Mobile devices are becoming powerful enough to realize augmented reality (AR) application. This paper introduces two AR methods to estimate an environmental illumination distribution of a scene. In the first method, we extract the lighting direction and intensity from input images captured with a front-side camera of a mobile device, using its orientation sensor. The second method extracts shadow regions cast by three dimensional (3D) AR marker of known shape and size. Because previous methods examine per pixel shadow intensity, their performances are much affected by the number of sampling points, positions, and threshold values. By using a simple binary operation between the previously clustered shadow regions and the threshold real shadow regions, we can compute efficiently their relative area proportions according to threshold values. This area-based method can overcome point sampling problem and threshold value selection. Experiment results demonstrate that the proposed methods generate natural image with multiple smooth shadows in real-time.

Low-Soil Disturbance In-Situ Test Method Development and Its Application : Screw Plate Loading Test (지반의 교란을 최소화 한 원위치시험법 개발 및 적용 : 스크류재하시험)

  • Lee, Yong-Su;Hwang, Woong-Ki;Choi, Yong-Kyu;Kim, Tae-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.977-986
    • /
    • 2009
  • Sampling disturbance can introduce considerable errors in the laboratory estimation of geotechnical properties of soils, and the results obtained from sophisticated sampling and careful laboratory testing are not matching with field behavior. Therefore, it is advantage to adopt in-situ testing techniques for the estimation of geotechnical parameters. Therefore, Screw plate loading test, one of new field test technologies, has been investigated in this study. This test can be utilized to find out important properties of soils such as load-displacement, elastic modulus, and shear strength. The screw plate loading test modified from the plate loading test is an experiment underneath ground by inserting a spiral type of auger screw. The structure and characteristics of the screw plate loading test device was examined in detail. In addition, The new screw plate loading test device was manufactured to refer the previous studies. The reliability of developing screw plate loading test was examined through the analysis of the laboratory test.

  • PDF

A Power-line Frequency Monitoring Intelligent Electronic Device(IED) Platform (전력선 주파수 모니터링을 위한 Intelligent Electronic Device(IED) 플랫폼)

  • Jeon, Hyeon-Jin;Yi, Don-Jin;Jeon, Jun-Gil;Chang, Tae-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.1047-1049
    • /
    • 2009
  • This paper presents an intelligent electronic device(IED) platform which is based on a new frequency estimation algorithm. The IED platform features not only the accurate estimation of frequency but also the fast network-based transmisstion of fault data and waveforms. The simulation results show that the proposed frequency estimation algorithm improves convergence speed, and has lower frequency estimation error compared with those of conventional algorithms. The network-based IED is designed to ensure transmission latency being less than 1.0% of sampling interval.

Development of Sugar Sensitive Drosophila Cell based ISFET Sensor for Alzheimer's Disease Diagnosis (알츠하이머 진단을 위한 당성분에 민감한 초파리 세포기반 ISFET센서개발)

  • Lim, Jeong-Ok;Yu, Joon-Boo;Kwon, Jae-Young;Byun, Hyung-Gi;Huh, Jeung-Soo;Cho, Won-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.281-285
    • /
    • 2013
  • In this study a biosensor was developed by using Drosophila cells expressing a gustatory receptor Gr5a and an ion sensitive field effect transistors (ISFETs) sensor device, which demonstrated significant compatibility with the Drosophila cells expressing Gr5a and their response to sugar. These results suggested that the newly developed cell based biosensor has a potential as a simple and easy screening device for Alzheimer's disease in the future.

Acceptability of Self-Sampling HPV Testing Among Thai Women for Cervical Cancer Screening

  • Oranratanaphan, Shina;Termrungruanglert, Wichai;Khemapech, Nipon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7437-7441
    • /
    • 2014
  • Background: Acceptability of self-sampling HPV testing is confirmed worldwide. However, some cultural differences may affect this question. Therefore, this study was conducted to evaluate the acceptability of self-sampling HPV testing in Thai women. Materials and Methods: One hundred women aged 30-65 years with an intact cervix were included in this study. The participants were asked to do the Pap test by physicians and then brush type self-sampling instruments were assigned for self-collection and finally completed a questionnaire for acceptability evaluation. The questionnaire contains 2 parts. Part one covered general information of the participants and part two is the acceptability questions. Results: Mean age was 40.6 years. The incidence of high risk HPV detection in this study was 16%. The most common reason for doing Pap smear was for annual checkup. On the topic of ease of use, 85 % of the subjects agreed. Most of the participants (82%) reported that they felt less pain. However, reliability of the result was not satisfactory because 37% of the participants hesitated to rely on the results of the test. According to the price, if the price is less than 1,000 Baht (32.59 Baht = 1USD), 82% of the subjects would use it for their next screening. Conclusions: The acceptability of self-sampling device in this study is quite good but the reliability of the test was questioned by some of the participants. Moreover, the price of the test in Thailand may also influence the acceptability of the test.