• Title/Summary/Keyword: Saliva-contaminated surface

Search Result 18, Processing Time 0.036 seconds

SURFACE DISINFECTION OF INTRAORAL FILMS (구내 방사선 필름의 표면소독효과에 관한 연구)

  • Lee Jin-Koo;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.329-335
    • /
    • 1992
  • The purpose of the study was to determine whether Sodium hypochlorite and Glutaraldehyde would be effective for the surface disinfection of contaminated radiographic film pockets with saliva The following results were as obtained 1. Proper times for surface disinfection of 2.0% Glutaraldehyde and 3.5% Sodium hypochlorite were 60 seconds. 2. When films were immerged in 2% Glutaraldehyde solution for 1 minute, baterial colonies were present in 24 cases(80%). 3. When films were immerged in 3.5% Sodium hypochlorite solution for 1 minute, bacterial colony was absent in 25 cases(83.3%). 4. Differences of effectiveness on surface disinfection between 2% Glutaraldehyde and 3.5% Sodium hypochlorite were statistically significant.

  • PDF

THE INFLUENCE OF SALIVARY CONTAMINATION ON SHEAR BOND STRENGTH OF PIT AND FISSURE SEALANT BY USE OF SEVERAL BONDING AGENTS (타액오염이 치면열구전색제의 전단결합강도에 미치는 영향)

  • Park, So-Yeon;Choi, Sung-Chul;Choi, Young-Chul;Kim, Kwang-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • The objective of this study was to assess the effect of salivary contamination on shear bond strength of pit and fissure sealant using several bonding agents by means of applying saliva at different stages of treatment. 56 teeth were randomly divided into one of seven groups (8 per group): (Group A, B) acid etching; (Group C, D, E) Adper$^{TM}$ Single Bond after acid-etching; (Group F, G) Adper$^{TM}$ Prompt L-pop. Saliva was applied to teeth surface of B, D, E, and G groups for 10 seconds. Especially, group D was contaminated after acid-etching and group E was contaminated with saliva after adhesive application. After light curing, all of the specimens were thermocycled and the shear bond strength tests were performed. The results were as follows. 1. In generally performed pit and fissure sealant group, shear bonding strength significantly differently reduced when was contaminated by saliva (p<0.05). However the group that was applied with bonding agent during pit and fissure sealant procedure, there were no significant differences in the kind of bonding agents nor the stage of contamination. 2. In group that was not contaminated by saliva during pit and fissure sealant treatment, Adper$^{TM}$ Single Bond yielded the highest bonding strength but there were no significant differences. 3. The failure pattern on the debonded surfaces shows that most specimens from groups using bonding agents showed cohesive failures while most specimens from groups that didn't use bonding agents showed adhesive failures.

THE EFFECT OF WASHING PHOSPHORIC ACID ETCHANT ON SHEAR BOND STRENGTH OF AN ORTHODONTIC ADHESIVE (인산 부식액의 수세가 교정용 접착레진의 전단결합강도에 미치는 영향)

  • Kim, Hee-Kyun;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.497-507
    • /
    • 1996
  • The aim of present study in vitro was to evaluate and compare the effects of different washing times of enamels etched with low phosphoric acid solution which makes unsoluble salts and etched but contaminated with saliva on shear bond strength of an orthodontic adhesive to enamel, and to observe the washing effect on the etched enamel surface by scanning electron microscope. All brackets were bonded with Mono-$Lok2^{TM)}$) on the labial surface of extracted human bicuspids after etching with $20w/w\%\;and\;37w/w$ and phosphoric acid solution for 60seconds and then washing for 0,5,10 and 20seconds respectedly. After etching with $37w/w\%$ phosphoric acid solution and contaminating with saliva for 30seconds and then washing for 0,5,20 and 30seconds and re-etching for 10seconds. After 24hours passed in the $37^{\circ}C$ water bath, the shear bond strengths were measured on Universal Test Machine. The data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. 1. There was no significant differences between (p>0.05) shear bond strength of bonded brackets with 5, 10, 20seconds washing etched enamel using $37{\%}w/w{\%}$ phosphoric acid solution. 2. The shear bond strength of bonded brackets with $20w/w\%$ phosphoric acid and then washing for 5seconds showed bonded strength durable to occlusal force but its coefficiency score was high and etched surface was not cleaned completely and therefore it was assumed that its clinical application is not applicable. 3. There was no significant differences between (p>0.05) shear bond strengths of bonded brckets with washing for 5seconds etched enamel using $37w/w\%$ phosphoric acid solution and 10,20 seconds washing etched enamel using $20w/w\%$ phosphoric acid solution. 4. The shear bond strength of washing for 5seconds etched enamel which was contaminated with saliva showed sufficient bonded strength durable to occlusal force but its coefficiency score was high and therefore its clinical application was not applicable. 5. After etching, the sample contaminated with saliva showed the sufficient shear bond strength even washing 20seconds without re-etching.

  • PDF

Cleaning and Decontamination Method of Books for Their Sanitary Circulation (책의 위생적 유통관리를 위한 세정 소독 방법)

  • Kim, Nam Yong;An, Duck Soon;Choi, Young Il;Jung, Yong Bae;Kim, Jung Min;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • In order to find a sanitary logistic way to handle library books, papers and environmental sources contacting the books were tested in their microbial contamination load and methods to decontaminate the books were investigated. Generally bacterial load of inner book pages was very low, but increased when contaminated with liquid such as saliva. In contrast, their lateral ends showed much higher bacterial contamination presumably due to dry dust contamination on there. As operations to improve the sanitary book conditions, turbulent air blow was found to be workable for reducing dry dusty contamination and 280 nm ultra-violet (UV) light emitting diode (LED) was so for decontaminating wet surface contamination. Microbial inactivation by the UV LED could be realized with irradiation for more than 5 minutes at 2 cm distance. Air blow of 5.5 m/s for 0.5~1 minute could reduce the dusty contamination on a model book surface.

  • PDF

The effect of cleaning methods on bond strength of zirconia after saliva contamination (타액으로 오염된 지르코니아 수복물의 접착강도에 세척 방법들이 미치는 영향)

  • Shim, Young-Bo;Choi, An-Na;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong Hoon;Park, Jeong-Kil
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • This study evaluated the effects of various cleaning methods on the shear bond strength of zirconia ceramics after saliva contamination. Eighty zirconia disk specimens were divided into 8 groups. All groups were treated with one coat of MDP primer. All specimens (except the negative control) were contaminated with human saliva on the zirconia surface. The positive control went through the bonding procedure immediately after contamination without any cleaning procedure. With the exception of control groups, the remaining six groups were rinsed with water and either applied with MDP recoating (WATER+MDP) or without MDP recoating (WATER). While some were cleaned with a Ivoclean with MDP recoating (IVOCLEAN+MDP) or not applied with MDP recoating(IVOCLEAN), others were cleaned with a 1% NaOCl solution with MDP recoating (NaOCl+MDP) or without MDP recoating (NaOCl). The shear bond strength of all specimens were measured after being stored in distilled water at $37^{\circ}C$ for 24 hours. The data was analyzed statistically by an analysis of ANOVA, Tukey's post hoc test and Student's t-test was used to compare the shear bond strength according to the re-coating of MDP after the cleaning procedure. The positive control group showed the lowest shear bond strength value, and the WATER group and NaOCl group showed no significant difference when compared to the positive control group. The IVOCLEAN group showed significantly higher shear bond strength when compared to Water group and NaOCl group but not with the group of negative control. After rinsing with water or the NaOCl solution, the comparison of the single coating of MDP and re-coating of MDP showed different shear bond strengths but there was no significant difference to the negative control. After rinsing with Ivoclean, there was no significant difference to the negative control regardless of the recoating of MDP. In conclusion, the shear bond strength was affected by the cleansing procedure and Ivoclean was found to be effective regardless of the re-coating of MDP. When water or the NaOCl solution is used to remove surface contaminants, the re-coating of MDP provides a positive effect on cementation.

New trends of root canal disinfection and treatment strategies for infected root canal based upon evidence-based dentistry

  • Cho, Yong-Bum
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.608-608
    • /
    • 2003
  • The main objectives of root canal therapy are cleaning and shaping and then obturating the root canal system in 3 dimensions to prevent reinfection. Many instrumentation techniques and devices, supported by an irrigation system capable of removing pulp tissue remnants and dentin debris, have been proposed to shape root canals. But current regimens in chemomechanical debridement using instrumentation and irrigation with NaOCl are not predictably effective in root canal disinfection. These findings are not surprising because the root canal system is complex and contains numerous ramifications and anatomical irregularities. The microorganisms in root canals not only invade the anatomic irregularities of the root canal system but also are present in the dentinal tubules. Therefore further disinfection with an effective antimicrobial agent may be necessary and it well1mown that use of intracanal medication will lower bacterial count in infected root canals. Calcium hydroxide has a long history of use in endodontics, and more attention has been given to the use of calcium hydroxide as intracanal dressing for the treatment of infected pulp. However, when treatment is completed in one visit, no intracanal medications other than intracanal irrigants are used. Recently, a mixture of a tetracycline isomer, an acid, and a detergent(MTAD), has been introduced as a final rinse for disinfuction of the root canal system. It has been shown that MTAD is able to remove the smear layer with minimal erosive changes on the surface of dentin, and is effective against Enterococcus faecalis, a microorganism resistant to the action of other antimicrobial medications. In another study, the ability of MTAD was investigated to disinfect contaminated root canals with whole saliva and compared its efficacy to that of NaOCl Based on the results, it seems that MTAD is significantly more effective than 5.25% NaOCl in eradicating bacteria from infected root canals. In the cytotoxicity evaluation, MTAD is less cytotoxic than engenol, 3% $H20_2,\;Ca(OH)_2$ paste, 5.25% NaGCl, Peridex, and EDTA and more cytotoxic than 2.63%,1.31% and 0.66% NaOCl. Is it promising or transient?

  • PDF

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

THE EFFECTS OF SALIVARY CONTAMINATION OF ACID-ETCHED ENAMEL ON BRACKET BOND STRENGTH (산부식 후 타액오염이 교정용 접착제의 결합강도에 미치는 영향)

  • Kim, Hyun-Deog;Kim, Jong-Sung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.309-316
    • /
    • 1996
  • The purpose of this study was to determine the effect of salivary contamination of etched enamel on shear bond strength of a bracket adhered to etched enamel. Eighty extracted human permanent premolars were used in this study. These samples were divided into two groups. Buccal surface of samples were etched in vitro with 38% phosphoric acid for 15 seconds and 60 seconds. Each group was divided into four subgroups. Etched enamel surfaces were contaminated with saliva for 0, 1, 20, 60 seconds, washed and dried. Test surfaces were examined using scanning electron microscope(SEM). The shear bond strength of each sample was determined with a universal testing instrument(Instron Co. Model 4201). Results were as follows; 1. Salivary contamination for 1, 20, 60 seconds did not affect shear bond strength when compared with the uncontaminated enamel group. 2 There was no significant difference(P>.05) in shear bond strength between 15 sec. and 60 sec. etching in uncontaminated enamel groups. 3. When samples were examined using SEM, organic materials coated enamel surface masked the etched pattern partially.

  • PDF