• Title/Summary/Keyword: Safety Risk

Search Result 5,889, Processing Time 0.037 seconds

A Study on Improving the Storm and Wind Damage Management System of Coastal Cities (연안도시 풍수해 관리체계 개선방안에 관한 연구)

  • Oh, Sang-Baeg;Lee, Han-Seok
    • Journal of Navigation and Port Research
    • /
    • v.43 no.3
    • /
    • pp.209-218
    • /
    • 2019
  • Coastal cities suffer a great deal of storm and wind damage. The storm and wind characteristics vary between cities. Therefore, a storm and wind damage management system suited for specific characteristics is required for each coastal city. In this study, we analyze the current situation and establish the problem of storm and wind damage management system in regards to urban management, coastal management and disaster management. We also review the storm and wind damage management system for the USA and Japan. We consequently propose a plan to improve the storm and wind damage management system. As a result of the study, in terms of city management, we recommend the compulsory identification of disaster prevention districts, implementation of the integrated coastal city management plan, designation of natural disaster risk mitigation area as disaster prevention district, the division of disaster prevention district into wind damage prevention district, storm damage prevention district, erosion damage prevention district, the building of restrictions at the disaster prevention district by ordinance, etc. In regards to coastal management, we suggest the delegation of authority to delegate coastal erosion management area to the local government, the subdivision of coastal erosion management area into erosion serious area, erosion progress area, erosion concern area, the building restrictions at coastal erosion management area by ordinance, development of erosion prediction chart, etc. In relation to disaster management, we recommend the integration of "countermeasures against natural disasters act" and "disasters and safety management basic act", the local government-led disaster prevention system, the local disaster management network, and the customized local disaster prevention plan, etc.

Prospects of future extreme precipitation in South-North Korea shared river basin according to RCP climate change scenarios (RCP 기후변화 시나리오를 활용한 남북공유하천유역 미래 극한강수량 변화 전망)

  • Yeom, Woongsun;Park, Dong-Hyeok;Kown, Minsung;Ahn, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.9
    • /
    • pp.647-655
    • /
    • 2019
  • Although problems such as river management and flood control have occurred continuously in the Imjin and Bukhan river basin, which are shared by South and North Korea, efforts to manage the basin have not been carried out consistently due to limited cooperation. As the magnitude and frequency of hydrologic phenomena are changing due to global climate change, it is necessary to prepare countermeasures for the rainfall variation in the shared river basin area. Therefore, this study was aimed to project future changes in extreme precipitation in South-North Korea shared river basin by applying 13 Global Climate Models (GCM). Results showed that the probability rainfall compared to the reference period (1981-2005) of the shared river basin increased in the future periods of 2011-2040, 2041-2070 and 2071-2100 under the Representative Concentration Pathways (RCP)4.5 and RCP8.5 scenarios. In addition, the rainfall frequency over the 20-year return period was increased in all periods except for the future periods of 2041-2070 and 2071-2100 under the RCP4.5 scenario. The extreme precipitation in the shared river basin has increased both in magnitude and frequency, and it is expected that the region will have a significant impact from climate change.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Perception and Practice level of Korean Medical Doctors on Infection Control and Prevention in Korean Medicine Facilities (한방의료기관 감염관리에 대한 한의사의 인식도와 수행도)

  • Shin, HeonTae
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.27-47
    • /
    • 2019
  • Purpose : This study was designed to identify the perception and practice level of infection control among korean medical doctors and to identify factors that may influence the performance and practice level. Methods : Data were collected using the on­line survey method. Seven hundred and eighty four Korean medical doctors(KMD) participated the survey. The study was conducted from December 2018 to January 2019. Results : The results of this study are as follows. 1. Participants who experienced infection risk by needles or sharp instruments were 596(76%). and participants who had experienced blood or body fluid contact with the mucous membrane or skin of the patient during treatment were 226(28.8%) of them. 2. The degree of perception and practice of the infectious guideline was higher in the group over 50 years, in the doctor group, in the group with more than 6 years experience in clinic and in the group who work in the hospital. (p < 0.05) 3. In the performance of the infection control management related to the Korean medical treatment, the practice level of the article 'Discard the remaining needle that used for one patient' was the lowest at 4.02, 'Identify the patient and check the validity period of sterilization of medicines or instruments' was the second lowest in 4.16. 4. Among the contents of "Prevention of Nosocomial infection and Sanitary Safety Guidelines" issued by the Korean Medical Association in 2008, the guideline "Prevention of infection by pathogens such as HIV, MRSA, SARS" were lowest article in the perception and practice level of participants. 5. Regression analysis was performed to find out the factors affecting perception and performance of the participants. The regression model showed significant difference in the regression model of the working years. (p < 0.05) 6. In order to examine the effect of the variables on the perception and practice of the infectious guideline, the mediated effect of the knowledge and education level according to the years of working, age, education degree was found to be significant only in the education degree variable. (p < 0.05) In conclusion : in order to improve the perception and practice of infectious control of Korean medicine doctors, it is necessary to include the contents of infection management as essential education during the continuing education of Korean medicine association.

Accuracy Analysis for Slope Movement Characterization by comparing the Data from Real-time Measurement Device and 3D Model Value with Drone based Photogrammetry (도로비탈면 상시계측 실측치와 드론 사진측량에 의한 3D 모델값의 정확도 비교분석)

  • CHO, Han-Kwang;CHANG, Ki-Tae;HONG, Seong-Jin;HONG, Goo-Pyo;KIM, Sang-Hwan;KWON, Se-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.234-252
    • /
    • 2020
  • This paper is to verify the effectiveness of 'Hybrid Disaster Management Strategy' that integrates 'RTM(Real-time Monitoring) based On-line' and 'UAV based Off-line' system. For landslide prone area where sensors were installed, the conventional way of risk management so far has entirely relied on RTM data collected from the field through the instrumentation devices. But it's not enough due to the limitation of'Pin-point sensor'which tend to provide with only the localized information where sensors have stayed fixed. It lacks, therefore, the whole picture to be grasped. In this paper, utilizing 'Digital Photogrammetry Software Pix4D', the possibility of inference for the deformation of ungauged area has been reviewed. For this purpose, actual measurement data from RTM were compared with the estimated value from 3D point cloud outcome by UAV, and the consequent results has shown very accurate in terms of RMSE.

Immune Checkpoint Inhibitors for Non-Small-Cell Lung Cancer with Brain Metastasis : The Role of Gamma Knife Radiosurgery

  • Lee, Min Ho;Cho, Kyung-Rae;Choi, Jung Won;Kong, Doo-Sik;Seol, Ho Jun;Nam, Do-Hyun;Jung, Hyun Ae;Sun, Jong-Mu;Lee, Se-Hoon;Ahn, Jin Seok;Ahn, Myung-Ju;Park, Keunchil;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.271-281
    • /
    • 2021
  • Objective : Immune checkpoint inhibitors (ICIs) are approved for treating non-small-cell lung cancer (NSCLC); however, the safety and efficacy of combined ICI and Gamma Knife radiosurgery (GKS) treatment remain undefined. In this study, we retrospectively analyzed patients treated with ICIs with or without GKS at our institute to manage patients with brain metastases from NSCLC. Methods : We retrospectively reviewed medical records of patients with brain metastases from NSCLC treated with ICIs between January 2015 and December 2017. Of 134 patients, 77 were assessable for brain responses and categorized into three groups as follows : group A, ICI alone (n=26); group B, ICI with concurrent GKS within 14 days (n=24); and group C, ICI with non-concurrent GKS (n=27). Results : The median follow-up duration after brain metastasis diagnosis was 19.1 months (range, 1-77). At the last follow-up, 53 patients (68.8%) died, 20 were alive, and four were lost to follow-up. The estimated median overall survival (OS) of all patients from the date of brain metastasis diagnosis was 20.0 months (95% confidence interval, 12.5-27.7) (10.0, 22.5, and 42.1 months in groups A, B, and C, respectively). The OS was shorter in group A than in group C (p=0.001). The intracranial disease progression-free survival (p=0.569), local progression-free survival (p=0.457), and complication rates did not significantly differ among the groups. Twelve patients showed leptomeningeal seeding (LMS) during follow-up. The 1-year LMS-free rate in treated with ICI alone group (69.1%) was significantly lower than that in treated with GKS before ICI treatment or within 14 days group (93.2%) (p=0.004). Conclusion : GKS with ICI showed no favorable OS outcome in treating brain metastasis from NSCLC. However, GKS with ICI did not increase the risk of complications. Furthermore, compared with ICI alone, GKS with ICI may be associated with a reduced incidence of LMS. Further understanding of the mechanism, which remains unknown, may help improve the quality of life of patients with brain metastasis.

Regional Lymph Node Dissection as an Additional Treatment Option to Endoscopic Resection for Expanded Indications in Gastric Cancer: a Prospective Cohort Study

  • Seo, Ho Seok;Yoo, Han Mo;Jung, Yoon Ju;Lee, Sung Hak;Park, Jae Myung;Song, Kyo Young;Jung, Eun Sun;Choi, Myung-Gyu;Park, Cho Hyun
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.442-453
    • /
    • 2020
  • Purpose: Expanded indications for endoscopic submucosal dissection (ESD) in early gastric cancer (EGC) remain controversial due to the potential risk of undertreatment after adequate lymph node dissection (LND). Regional LND (RLND) is a novel technique used for limited lymphadenectomy to avoid gastrectomy. This study established the safety and effectiveness of RNLD as an additional treatment option after ESD for expanded indications. Materials and Methods: A total of 69 patients who met the expanded indications for ESD were prospectively enrolled from 2014 to 2017. The tumors were localized using intraoperative esophagogastroduodenoscopy (EGD) before RLND. All patients underwent RLND first, followed by conventional radical gastrectomy with LND. The locations of the preoperative and intraoperative EGD were compared. Pathologic findings of the primary lesion and the RLND status were analyzed. Results: The concordance rates of tumor location between the preoperative and intraoperative EGD were 79.7%, 76.8%, and 63.8% according to the longitudinal, circumferential, and regional locations, respectively. Of the 4 patients (5.7%) with metastatic LNs, 3 were pathologically classified as beyond the expanded indication for ESD and 1 had a single LN metastasis in the regional lymph node. Conclusions: RLND is a safe additional option for the treatment of EGC in patients meeting expanded indications after ESD.

Method for evaluating the safety performance and protection ability of the mobile steel protective wall during the high-explosive ammunition test (고폭탄 탄약시험 간 이동형 강재 방호벽의 안전성능 판단 및 유효 방호력 평가 방법)

  • Jeon, In-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.573-582
    • /
    • 2021
  • In this study, a series of processes for evaluating the effective protection against barriers that should be equipped in institutions that perform reliability tests on high-risk ammunition, such as high-explosive ammunition, were introduced. The impact that high-explosive bombs can have on personnel includes damage to the eardrum and lungs caused by explosion overpressure and penetrating wounds that can be received by fragments generated simultaneously with the explosion. Therefore, a high-explosive with COMP B explosives as its contents were set up, and an explosion protection theory investigation to calculate the degree of damage, numerical calculations and simulations were performed to verify the protection power. A numerical calculation revealed the maximum explosion overpressure on the protective wall when the high-explosive exploded and the penetration force of the fragment against a 50 mm-thick protective wall to be 77.74 kPa and 41.34 mm, respectively. In the simulation verification using AUTODYN, the maximum explosion overpressures affecting the firewall and personnel were 56.68 kPa and 18.175 kPa, respectively, and the penetration of fragments was 35.56 mm. This figure is lower than the human damage limit, and it was judged that the protective power of the barrier would be effective.

Design and Implementation of a Hardware Accelerator for Marine Object Detection based on a Binary Segmentation Algorithm for Ship Safety Navigation (선박안전 운항을 위한 이진 분할 알고리즘 기반 해상 객체 검출 하드웨어 가속기 설계 및 구현)

  • Lee, Hyo-Chan;Song, Hyun-hak;Lee, Sung-ju;Jeon, Ho-seok;Kim, Hyo-Sung;Im, Tae-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1331-1340
    • /
    • 2020
  • Object detection in maritime means that the captain detects floating objects that has a risk of colliding with the ship using the computer automatically and as accurately as human eyes. In conventional ships, the presence and distance of objects are determined through radar waves. However, it cannot identify the shape and type. In contrast, with the development of AI, cameras help accurately identify obstacles on the sea route with excellent performance in detecting or recognizing objects. The computer must calculate high-volume pixels to analyze digital images. However, the CPU is specialized for sequential processing; the processing speed is very slow, and smooth service support or security is not guaranteed. Accordingly, this study developed maritime object detection software and implemented it with FPGA to accelerate the processing of large-scale computations. Additionally, the system implementation was improved through embedded boards and FPGA interface, achieving 30 times faster performance than the existing algorithm and a three-times faster entire system.

Quality Control Tests and Acceptance Criteria of Diagnostic Radiopharmaceuticals (진단용 방사성의약품의 품질관리시험 및 기준)

  • Park, Jun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Radiopharmaceuticals are drugs that contain radioisotopes and are used in the diagnosis, treatment, or investigation of diseases. Radiopharmaceuticals must be manufactured in compliance with good manufacturing practice regulations and subjected to quality control before they are administered to patients to ensure the safety of the drug. Radiopharmaceuticals for administration to humans need to be sterile and pyrogen-free. Hence, sterility tests and membrane filter integrity tests are carried out to confirm the asepticity of the finished drug product, and a bacterial endotoxin test conducted to assess contamination, if any, by pyrogens. The physical appearance and the absence of foreign insoluble substances should be confirmed by a visual inspection. The chemical purity, residual solvents, and pH should be evaluated because residual by-products and impurities in the finished product can be harmful to patients. The half-life, radiochemical purity, radionuclidic purity, and strength need to be assessed by analyzing the radiation emitted from radiopharmaceuticals to verify that the radioisotope contents are properly labeled on pharmaceuticals. Radiopharmaceuticals always carry the risk of radiation exposure. Therefore, the time taken for quality control tests should be minimized and care should be taken to prevent radiation exposure during handling. This review discusses the quality control procedures and acceptance criteria for a diagnostic radiopharmaceutical.