• 제목/요약/키워드: Safety Facilities

검색결과 3,175건 처리시간 0.026초

영유아 급식소 위생관리 수행도 현장평가 (Field Assessment of Food Safety Management at Preschool Foodservice Establishments)

  • 배현주;이혜연;류경
    • 한국식품조리과학회지
    • /
    • 제25권3호
    • /
    • pp.283-296
    • /
    • 2009
  • This study examined food safety management at preschool establishments in Daegu and Gyeongbuk province, to provide data that can be used for food safety improvements. Field assessments of 60 foodservice establishments were executed from July to October, 2007. Statistical analyses of the data were conducted using the SPSS package program (version 14.0 for windows). The results are summarized as follows: 93.3% of the preschool foodservices were self-operated, and 24.1% of the child care centers and 96.7% of the kindergartens had employed dietitians. According to the averaged food safety evaluation scores the kindergartens (80.73) had a significantly higher score than the child care centers (50.37), and the public centers (85.00) had a significantly higher score than the private centers (54.29). While the average score of facilities that employed dietitian (73.58) was significantly higher than that of facilities that did not employ a dietitian (52.65). In addition, the average score of facilities that served meals in a dining room (80.83) was significantly higher than that of facilities that served meals in a classroom (59.33). The highest scoring food safety items included verifying employee health inspection reports (1.87), utilizing non-municipal water and routinely cleaning and well-maintaining the water storage tank (1.85), and disposing small amounts of leftovers in a vat after serving (1.83). In contrast, the lowest scores were for physical separation of clean areas and unclean areas to prevent cross-contamination (0.52), and physical separation between staff and food material entry areas (0.62). In conclusion, the preschool foodservice evaluated in this study required improvements in food safety management, and many of the child care centers were in need of immediate attention. To improve food safety at these establishments, administrators should implement prerequisite food safety programs.

AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구 (Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis)

  • 이정한;김용곤;이재원;김종훈
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

발전시설물 폭발에 대한 확률적 구조물 안전성평가 방안 (Probabilistic Structure Safety Assessment Method on the Explosion of Power Facilities)

  • 김정훈;김영구;강승규
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.317-317
    • /
    • 2014
  • The structure performance of a sealed power facilities and the explosion simulation contains significant amounts of scatter, and variability has been characterized in material properties of the structure, a sealed space density, combustible gas volume, gas concentrativeness, ignition site, and gas volume. In order to deal with such uncertainties, structural reliability analysis calculates the failure probability and the reliability index relevant to selected limit states providing quantitative measures of these uncertainties. In this study, structure safety assessment method on the explosion of a sealed power facilities was proposed by using the response surface method (RSM).

  • PDF

스크리닝 도구를 이용한 건물관리업 종사자의 균형감각능력 평가 (Evaluation of Balance Capability in Facilities Maintenance Workers using Screening Tools)

  • 최형진;김정수
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.81-88
    • /
    • 2014
  • A number of screening tools have been developed to evaluate the human balance capability. Many of them were designed to identify the elderly with falling risk. Three different screening tools, which have been well used many clinical fields, were used in this study. The purpose of this study was to evaluate balance capability in facilities maintenance workers in korea. There were no statistical significance between male and female when evaluated with three different screening tools. However, significant differences were found among the age groups irrespective of gender when evaluated with three different screening tools. The results of three different screening tools in korea showed poor values compared with previous results. These results revealed that facilities maintenance workers faced more critical falling risk in korea.

안전 및 유지관리기반 국내 인프라 실태조사 수행 방안 (The Method on Safety and Maintenance Based Domestic Infrastructure Facilities for Survey of Actual Condition)

  • 이정석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2015
  • Recently, although researching and developing of safety and maintenance on domestic infrastructure facilities in KOREA are important, there has been very little research regarding on a comprehensive and integrated survey of actual condition. Therefore this study asserts the necessity of the survey process of actual condition by period planning(short-term, middle-term, long-term). The purpose of this study is to investigate current situation and to suggest the whole process method, and to establish survey process of actual condition on domestic infrastructure facilities.

  • PDF

주거시설의 화재통계를 이용한 화재안전설계를 위한 기초적 연구 (A Basic Study on the Safety Design using the Fire Statistics of Residential Facilities)

  • 윤웅기;서동구;김동은;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2013
  • A study on the fire scenario proposal of residential facilities by using fire statistics. as a result of analyzing residential facilities fires by using fire statistics of national emergency management agency during 2007~2012, fires from carelessness were the most causes. specially, fires during food cooking among carelessness showed the highest occurrence frequency, and followed sparks, neglecting fire sources, and cigarette stubs in order. through this the study suggested fire scenarios according, It is believed that can be used as basic data for applying a secure building in a fire using a basis for fire safety design of buildings in the future this.

  • PDF

학교시설 외부 안전환경 현황 조사연구 - 학교 주변 통학로를 중심으로 - (A Study for Safety Environment around School Facilities. - Focused on School Routes -)

  • 맹준호;김관영;김성중;박영빈;신소영;김효선
    • 교육녹색환경연구
    • /
    • 제19권2호
    • /
    • pp.1-10
    • /
    • 2020
  • 학교시설에 대한 안전관리 등에 대한 법적, 제도적 장치가 있음에도 불구하고 학교안전사고 발생 건수는 지속적으로 유지되고, 특히 최근에는 통학 관련한 사고유형 증가하고 있다. 하지만 학교시설은 통학환경에 대한 관리주체가 학교, 교육청 등이 아닌 지자체 등에 있어 안전한 통학환경 조성에 어려움이 존재하고 있고 교육청 및 교육부에서도 별다른 통학 안전 환경에 대한 기준 및 체계 등 제도적 장치가 미흡한 시점에서 학교시설 안전을 향상하기 위해 방향을 확인하고자 하였다. 이를 위해 국내·외 학교시설 외부 환경 안전을 위한 조사한 자료들을 바탕으로 도출한 4가지(보차분리, 보행로 관리, 보행 시야 확보, 주변 위험요소) 안전평가항목을 설정, 전국 179개 학교시설(유치원, 초등학교, 중학교, 고등학교 및 특수학교)의 국내 사례를 대상으로 통학로를 중심으로 현황 분석하였다. 평가 항목에서 절반 이상의 지역에서 평가 점수의 50% 이하로 평가되었다. 이에 해당 평가 항목을 반영하여 학교시설의 외부 환경에 대한 개선이 노력이 요구되며, 이를 위한 제도적 장치마련 및 행정적 개선 방향 등을 모색할 필요가 있다.

전기안전기술 로드맵 설계 연구 (A Study on the Roadmap Design for Electrical Safety Technology)

  • 신흥식;이재천;이병길
    • 대한안전경영과학회지
    • /
    • 제9권3호
    • /
    • pp.1-7
    • /
    • 2007
  • A roadmap for Electrical Safety Technology has been designed based on the study that has been contributed by the specialists, professors and researchers in electral safety field. The roadmap is divided into five major fields including, for instance, the electrical fire accidents roadmap. The other four roadmaps are for electrical shock accidents, electrical facilities accidents, electrical safety policies and electrical safety culture-education, respectively. Each roadmap has a purpose, a scope, and a technical characteristic. Following the roadmaps can result in significant reduction of electrical fire accidents, electrical shock accident victims and so forth. The result can also be utilized in guiding the planning and development of the future electrical safety technology.

대국민 안전체험교육장의 체험교육 실태 및 개선방향 (Realities of experience in the place of safety experience education and propose the reform measure)

  • 김태환
    • 한국재난정보학회 논문집
    • /
    • 제2권1호
    • /
    • pp.81-89
    • /
    • 2006
  • As the quality of the rising the desire for safety life and the need of safety education to prevent disasters or big safety accident have been shown. Therefore the superintendent of education for safety experience carry out a policy for set up. However, it is unclear the appropriateness of safety education program and safety standard of facilities of introductions in the safety experience center. therefore, in the result of this study will be the basic information for the realities of experience in the place of safety experience education and propose the reform measure.

  • PDF