• Title/Summary/Keyword: SPDs

Search Result 54, Processing Time 0.027 seconds

Design and Fabrication of a Surge Protective Device for Electrical Mains on Shipboard (전원회로용 서지방호장치의 설계 및 제작)

  • Moon, Seung-Bo;Park, Dae-Won;Song, Jae-Yong;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1035-1040
    • /
    • 2005
  • This paper deals with the design rule and performance results of the surge protective devices (SPDs) for low-voltage mains on shipboard. The proposed SPDs consists of a metal oxide varistors (MOV) and a L-C filter to improve noise-elimination performance. Three kinds of SPDs are fabricated and tested by using a combination surge generator which produce the standard impulse current of 8/20${\mu}s$ 2.1kA. As a results, the proposed SPDs with series L-C filter have more excellent transient blocking and noise reduction performance than the conventional ones.

  • PDF

Empirical Performance Test of SPDs used in Communication Networks (통신용 SPD 성능평가를 위한 실증시험)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1464-1465
    • /
    • 2007
  • The purpose of this paper is to identify the requirements for Surge Protective Devices (SPDs) used in protecting telecommunication and signalling system. All of these systems may be exposed to the effects of lightning and power line faults, either through direct contact or induction. These effects may subject the system to overvoltages or overcurrents or both, whose levels are sufficiently high to harm the system. SPDs are intended to provide protection against overvoltages and overcurrents caused by lightning and power line faults. This paper describes tests and requirements which establish methods for testing SPDs and determining their performance.

  • PDF

Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices (RCD와 SPD의 접속 위치에 따른 보호협조)

  • Lee, Bok-Hee;Park, Hee-Yeoul;Shin, Gun-Jin;Bae, Gwan-Young;Ryu, Chun-Hyoung;Lee, Kang-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

Coordination between Voltage-Limiting Surge Protective Devices in Surge Currents Caused by Direct Lightning Flashes

  • Shin, Hee-Kyung;Lee, Jae-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.116-125
    • /
    • 2015
  • This paper presents experimental results obtained from actual installation conditions of surge protective devices (SPDs), with the aim of understanding the coordination of cascaded Class I and Class II SPDs. This paper also proposes effective methods for selecting and installing coordinating cascaded SPDs. The residual voltage of each SPD and the energy sharing of an upstream Class I tested SPD and a downstream Class II tested SPD were measured using a $10/350{\mu}s$ current wave. In coordinating a cascaded voltage-limiting SPD system, it was found that energy coordination can be achieved as long as the downstream SPD is a metal oxide varistor with a higher maximum continuous operating voltage than the upstream SPD; however, it is not the optimal condition for the voltage protection level. If the varistor voltage of the downstream SPD is equal to or lower than that of the upstream SPD, the precise voltage protection level is obtained. However, this may cause serious problems with regard to energy sharing. The coordination for energy sharing and voltage protection level is fairly achieved when the cascaded SPD system consists of two voltage-limiting SPDs separated by 3 m and with the same varistor voltage.

Protection Effects Associated with the Conditions for the Installations of SPDs (SPD의 설치조건이 보호효과에 미치는 영향)

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Seung-Chil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.60-67
    • /
    • 2006
  • This paper presents the protection effect of surge protective devices(SPDs) according to the conditions of installations. To propose the effective protection measures of information and communication equipments against lightning surges, actual-sized experiments in relation to the protection effects on the positions of installations of SPDs, the length of branch circuit, the wiring methods, and the materials of conduit, were conducted. The effective method of protecting information and communication equipments from lightning surges is to install SPDs in the vicinity of input terminals of each electronic equipments to be protected. The wiring method of connecting an SPD minimizing the length of leads is desirable when point-to-point wiring is to be used.

Protection Effects According to the Conditions of Installations of SPDs for Information-Oriented Equipments (정보화 기기용 SPD의 설치조건에 따른 보호효과)

  • Lee, Bok-Hee;Lee, Dong-Moon;Cheong, Dong-Chul;Lee, Su-Bong;Lee, Seung-Chil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Recently, there are increasing social needs for stable supply of electric power and securing high quality of information and communication services. In this work, to propose the effective protection countermeasures of information-oriented equipments against lightning surges, the protection effects of surge protective devices(SPDs) were experimentally investigated using actual-sized test circuits in various installation conditions. As a result, it was found that the protection effect of SPDs is quite different depending on the factors, such as the grounding system of power source, numbers of branch circuits, wiring method of grounding leads, and etc. In case of installing SPDs for information-oriented equipments, including all electric power lines and communication lines, the common grounding should be the most effective. Wiring method containing grounding leads with power lines in metal conduit is suitable to improve the surge cutoff performance of SPDs.

Sliced Profile-based Automatic Extraction of Machined Features from CSG Models (단면 재구성을 통한 CSG 모델의 기계가공부품 형상추출)

  • Lee, Young-Rai
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.20 no.1
    • /
    • pp.99-112
    • /
    • 1994
  • This paper describe the development of a systematic method of slicing solid parts based on a data structure called Sliced Profile Data Structure(SPDS). SPDS is an augmented polygon data structure that allows multiple layers of sliced profiles to be connected together. The method consists of five steps: (1) Selection of slicing directions, (2) Determination of slicing levels, (3) Creation of sliced profiles, (4) Connection of sliced profiles, and (5) Refinement. The presented method is aimed at enhancing the applicability of CSG for manufacturing by overcoming the problem of non-uniqueness and global nature. The SPDS-based method of feature extraction is suitable for recognizing broad scope of features with detailed information. The method is also suitable for identifying the global relationships among features and is capable of incorporating the context dependency of feature extraction.

  • PDF

A Study on the Development of Nuclear Safety Parameter Display System for Korean Nuclear Power Plants (한국원전의 SPDS 개발에 관한 연구)

  • Kim, Dong-Hoon;Moon, Byung-Soo;Kim, Jae-Hee
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.42-50
    • /
    • 1987
  • Through a project "Development of Nuclear Safety Parameter Monitoring System", a nuclear data link system was established between Kori nuclear unit 2 and Nuclear Safety Center. We present in this paper the selected parameter sets, a description of the developed pseudo-network software and the functional descriptions of the equipments involved. We also include the conceptual design of the Kori four unit ERF/SPDS system, along with the localization direction for the related software and hardware. hardware.

  • PDF

Development of a Surge Protective Device for Signal Lines on Shipboard (선박 신호회로용 서지방호장치의 개발)

  • Seo, Hwang-Dong;Song, Jae-Yong;Han, Ju-Seop;Kim, Yoon-Sik;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1161-1165
    • /
    • 2005
  • Due to the miniaturization of electrical components and assembles on signal circuits, transient overvoltages caused by switching operation or lightning surges have become more interesting concern to the field of electrical engineering. In this paper, the development of surge protective devices(SPDs) that can protect sensitive signal device on shipboard from overvoltages are described. Two kinds of SPDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}s$ 2.1kA according to the IEC 61000-4-5 standard. From the simulation and experimental results, it is confirmed that the proposed SPDs have an enough protection performance with a low insertion loss and a low clamping voltage.

  • PDF

Analysis of Current Status and Drug Expenditure of Drug Shortage Prevention Program (퇴장방지의약품관리제도의 운영 현황과 약품비 분석)

  • Chae, Su-Mi;Lee, Eui-Kyung
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.160-164
    • /
    • 2008
  • This study investigated the current status and drug expenditure of the drug shortage prevention program in Korea. National health insurance claims data from 2001 to 2005 were analyzed for the drugs with inadequate supply, which were designated as shortage prevention drugs (SPDs). Drug use of SPDs have increased every year, but the average increase rate of drug expenditure for SPDs, 13.5% was lower than that for all the reimbursed drugs, 18.6%. Drugs with price increase based on production cost were more actively used than drugs with prescription incentives for doctors.