• Title/Summary/Keyword: SC wall

Search Result 99, Processing Time 0.024 seconds

Analysis of Compression Characteristics of the Steel Plate-Concrete Wall Structures with Openings (개구부가 있는 강판콘크리트 벽체의 압축특성 분석)

  • Choi, Byong-Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.245-256
    • /
    • 2012
  • The objective of this study is to investigate the effect of the openings on the structural behavior of SC walls. The test parameters were with or without the reinforcing of openings and sleeve thickness. The common failure showed that the crack in the concrete progressed with the plate's local buckling between the shear connectors. The failure of the openings showed that the vertical wall of the sleeve buckled toward the opening inside. The plate buckling load showed a similar value with or without the sleeve of the opening, respectively. However, the maximum compressive strength of the specimen without the opening was higher than that of specimen with the opening.

Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House (창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로)

  • Kim, Kyung-Ah;Moon, Hyeun-Jun;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars (스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가)

  • Koo, Jimo;Lee, Kyungkoo;Kim, Wonki;Lee, JongBo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.129-138
    • /
    • 2016
  • Buckling of surface plates is an important limit state in Steel-Plate Concrete (SC) walls under axial compression. The surface plates may be anchored to concrete using connectors of studs or tie-bars. In this paper, the effects of studs and tie-bars on buckling of surface plates were evaluated by conducting tests. Experiments have three types of connectors; all studs, all tie-bars, and the combination of studs and tie-bars. Also, experiments have the various ratios of stud or tie-bar spacing to surface plate thickness. The experimental investigation shows that the buckling shape and strength of the surface plate of SC wall with the combination of studs and tie-bars have good agreements with that of the surface plate of SC walls with all studs or all tie-bars.

Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment (휨모멘트를 받는 강판 콘크리트(SC) 벽체에서 스터드의 성능개선을 위한 해석적 연구)

  • Cho, Sung-Gook;Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • In this study, it was conducted to improve the performance of stud of Steel Plate Concrete(SC) walls subjected to bending moment. Non-linearity of contact interface, connection, and material properties were considered in finite element modeling of SC wall. In order to validate the analytical model, furthermore, a foregoing laboratory experiment was simulated by FEM, so that comparison between the measured result and the analysis result have be done. The size of the analytical model was determined by reflecting various references and the analyses were performed according to various shapes and arrangements of stud. Additionally, the validity of the model considering the related provisions in the KEPIC SNG standard was also considered. As a result, the optimal shape and spacing of studs was proposed through this numerical analysis and standard verification.

Flexural Strength Evaluation of Steel Plate Concrete Shear wall subject to Monotonic Loading (단조하중을 받는 SC 전단벽의 휨강도 평가)

  • Kwon, Min-Ho;Kim, Jin-Sup;Seo, Hyun-Su;Lim, Jeong-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.9-14
    • /
    • 2013
  • In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.

Out-of-Plane Shear Strength Models of SC Wall (SC 벽체의 면외 전단강도 특성)

  • Hon, Sung-Gul;Lee, Kyuong-Jin;Park, Dong-Soo;Kim, Won-Ki;Lee, Dong-Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.225-228
    • /
    • 2008
  • This paper presents out-of-plane shear strength models for composite wall with steel plates based on limit theorem in the framework of the plasticity theory. The formulas proposed by JEAG 4618 need to be reconsidered with a couple of limitations; ignoring the effect of bond stress generated by studs in the process of calculating arch action, illogically discriminating between concrete shear cracking strength and arch strength by algebraic relation in short shear span ratio(0-2.0). In most cases, reinforcement ratio is not sufficient to yield, as a result, arch strength is determined by accounting equilibrium including both bond strength and concrete compressive strength. We conducted experimental research assuming that SC wall is a continuous beam under the simplified loading patterns, changing main valuables involving the number of studs, stirrups. The results show good agreements with the formula and we quoted the test results of JEAG.

  • PDF

An Experimental Study on Mechanical Properties of SC Beam Structure under Temperature Load (강판콘크리트(SC : Steel Plate Concrete) 보의 온도하중 재하 시 역학적 특성에 관한 실험연구)

  • Lee, Kyung Jin;Ham, Kyung Won;Park, Dong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.443-450
    • /
    • 2009
  • This paper describes the experimental study that was conducted on the temperature characteristic and bending capacity of a steel-plate-reinforced concrete-wall module (SC module). The steel plate ratio and temperature loading parameters were tested, and the influence of these parameters on the moment-curvature relationship and on the bending strength of the SC module was investigated. The fundamental-structure characteristic result of every SC module that assumed practical use was investigated. In this study, the bending and flexural characteristics of SC structures were evaluated to verify the yielding and ultimate strength of the SC beam under thermal-loading conditions.

An Analytical Study on the Structural Behavior of SC walls with Opening (개구부를 갖는 SC 벽체의 거동에 관한 해석적 연구)

  • Lee, Seung Joon;Choi, Byong Jeong;Kang, Shin Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.233-243
    • /
    • 2009
  • The objective of this study was to investigate the effect of openings on the structural behavior of SC walls. The FEM program ABAQUS was used in this analytical study. The main parameters were the locations and sizes of the openings: a total of 20 locations and a total of four opening sizes were adopted. The analysis results were compared with the results of the currently applied evaluation methods. The strength reduction factor method may be used to safely design SC walls with openings. The strength reduction factor of the effective strut method is more similar to that of the analysis results.

Experimental Investigation of the Lateral Load Capacity and Strength Characteristics of a Steel Plate Concrete (SC) Shear Wall (비보강 강판콘크리트 전단벽의 횡하중 성능 및 강도특성에 대한 실험적 평가)

  • Cho, Sung-Gook;So, Gi-Hwan;Kim, Doo-Kie;Kwon, Min-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.23-32
    • /
    • 2012
  • Research on steel plate concrete (SC) structures for the modularization of nuclear power plants have been performed recently in Korea. In this study, the seismic capacity and stiffness characteristics of unstiffened SC shear walls under the effects of earthquakes were investigated through static pushover tests. Failure modes, sectional strength, and stiffness characteristics of SC structures under lateral loads were inspected by analyzing the experimental results. The strengths obtained by the experiments were also compared with those derived by the design code of the SC structures. One of the main failures of unstiffened SC shear walls was found to be the type of bending shear failure due to the debonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC structures.