Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment |
Cho, Sung-Gook
((주)제이스코리아 기술연구소)
Lim, Jin-Sun (서울연구원 안전환경연구실) Jeong, Young-Do (포스코건설 R&D센터 기술연구소) Yi, Seong-Tae (인하공업전문대학 토목환경과) |
1 | Evans, R. H., and Marathe, M. S. (1967), Microcracking and stress-strain curves for concrete in tension, Materials and Structures, 1(1), 61-64. |
2 | Carreira, D. J., and Chu, K. H. (1985), Stress-strain relationship for plain concrete in compression, ACI Journal, 82(6), 797-804. |
3 | Cho, S. G., So, G. H., Kim, D. K., and Kwon, M. H. (2012), Experimental Investigation of the Lateral Load Capacity and Strength Characteristics of a Steel Plate Concrete (SC) Shear Wall, Journal of the Earthquake Engineering Society of Korea, 16(15), 23-32 (in Korean). 과학기술학회마을 DOI ScienceOn |
4 | Choi, M. S. (2007), A Study on the Structural Behavior of Steel Plate-Concrete Wall System, Master Thesis, Ajou University (in Korean). |
5 | Jankowiak, T., and Lodygowski, T. (2005), Identification of parameters of concrete damage plasticity constitutive model, Foundation of civil and environmental engineering, Poznan University of Technology, Poland, No. 6, 53-69. |
6 | Japan Electric Association (JEA) (1991), Technical Guidelines for A Seismic Design of Nuclear Power Plants, JEAG-4601, Japan Electric Association, Tokyo, Japan (in Japanese). |
7 | Kim, T. G. (2008), Behavior of Steel plate-concrete composit wall under shear and bending moment, Master Thesis, Ajou University (in Korean). |
8 | Koera Electric Association (KEA) (2010), Nuclear Safety Related Structures : Steel-Plate Concrete Structure, KEPIC-SNG, Koera Electric Association. |
9 | Korea Concrete Institute (2012), Concrete Design Code (in Korean). |
10 | Moon, I. H., Yoo, S. T., Kim, T. Y., and Lee, H. W. (2006), Fundamental Study of Steel Plate Reinforced Concrete (SC) Structure, KSCE Conference & Civil Expo, KSCE, Gwangju, 429-432 (in Korean). |
11 | Ozaki, M., Akita, S., Oosuga, H., Nakayama, T., and Adachi, N. (2004), Study on Steel Plate Reinforced Concrete Panels Subjected to Cyclic In-Plane Shear, Nuclear Engineering and Design, 228(1-3), 225-244. DOI ScienceOn |
12 | Varma, A. H., Malushte, S. R., Sener, K. C., and Booth, P. N. (2012), Analysis Recommendations for Steel-Composite (SC) Walls of Safety Related Nuclear Facilities, Structures Congress of ASCE, ASCE, Chicago, 1871-1880. |
13 | Prakash, A., Anandavalli, N., Madheswaran, C. K., Rajasankar, J., and Lakshmanan, N. (2011), Three Dimensional FE Model of Stud Connected Steel-Concrete Composite Girders Subjected to Monotonic Loading, International Journal of Mechanics and Applications, 1(1), 1-11. |
14 | Varma, A. H., Zhang, K., Chi, H., Booth, P. N., and Baker, T. (2011), In-Plane Shear Behavior of SC Walls: Theory Vs. Experiment, Trans. of the Internal Assoc. for Struct. Mech. in Reactor Tech. Conf., SMiRT-21, New Delhi, India, Paper No. 764. |