• Title/Summary/Keyword: SAg

Search Result 701, Processing Time 0.03 seconds

A New Characterizing Method for Non-Rectangular Sag (Non-Rectangular Sag를 고려한 새로운 Sag의 평가 방법)

  • Won, D.J.;Chung, I.Y.;Kim, J.M.;Ahn, S.J.;Moon, S.I.;Seo, J.C.;Choe, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.304-306
    • /
    • 2002
  • This paper presents a new method to characterize sag event. Power quality monitoring algorithm to analyze PQ problems is described. This paper shows that conventional characterizing method which makes use of only sag magnitude and sag duration has some limitations. It characterizes non-rectangular sag as more severe one. In addition, it can't count on voltage tolerance characteristics of each apparatus. In order to solve these problems, this paper present a new characterizing method and it properly characterizes non-rectangular sag considering the voltage tolerance characteristics.

  • PDF

Method to Determine Areas of Vulnerability for Calculating Sag Cumulative Table and Sag Density Table (순간전압강하 누적 테이블 및 밀도 테이블 계산을 위한 취약지역 결정 방법)

  • Park, Chang-Hyun;Lee, Hansang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.746-751
    • /
    • 2014
  • This paper presents a method to calculate a sag cumulative table and density table based on the area of vulnerability to voltage sags. The expected sag performance at sensitive load points can be easily assessed through the calculation of the sag cumulative table and density table. However, the calculation of the tables regarding large power systems is very difficult task. Therefore, an efficient method for calculating the tables is needed. In this paper, the improved method to determine the areas of vulnerability is addressed and the method to calculate the tables based on the area of vulnerability is also described. The proposed scheme can be efficiently used to assess the voltage sag performance at sensitive load points in large power systems.

A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag (순간전압강하에 대한 비선형 저압전기기기의 동적특성)

  • Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

Analysis of the Contact Wire Wear Pattern According to the Pre-sag (사전이도에 따른 전차선 마모 패턴 분석)

  • Lee, In-Hee;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1501-1507
    • /
    • 2015
  • The contact wire pre-sag in railway overhead catenary has been considered as a innovative idea which improves the current collection quality and is expected to evenly distribute wear along a span. However, long term studies on the effects of pre-sag, especially on the quantitative wear pattern of the contact wire, have not yet been reported. Therefore, in this study, the pre-sag and wear pattern of the contact wire along a span from long term operation of railway in Korea was surveyed. The examination was conducted on 3 lines, the Gyeongbu high-speed line with pre-sag of span/2000, the Gyeongbu existing line without pre-sag, and Gyeongchun line with pre-sag installation on 1/1000 of its span. The wear measurements of 58 sample spans were examined. The wear pattern analysis show no interrelationships between pre-sag and evenly distributed wear, but more wear occurred at the center of a span compared to the ends of the span, especially more noticeable as span length increases.

Development of On-Line Type Voltage Sag Compensation Systems by Using a Supercapacitor (수퍼커패시터를 이용한 상시가동형 순시전압강하 보상시스템의 개발)

  • Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • This paper deal with development of on-line type voltage sag compensation system using supercapacitor EDLC to solve the voltage sag problems which are considered to be dominant disturbances affecting the power quality. With the wide use of semiconductor devices in electrical equipment, modem-type loads are becoming increasingly sensitive to the voltage sags and the disturbances prove to be costly to industries. Supercapacitor EDLC is employed to compensate dynamically for the voltage sag of system with sensitive loads. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. Therefore, in this paper, the energy design scheme of supercapacitor and the configuration technique of on-line type voltage sag compensation systems are newly introduced. According to the results of experimental of prototype 5[kVA] system, it is verified that the developed system has effectiveness of voltage sag compensation by using a supercapacitor EDLC.

Development of Three Phase 10kW Voltage Sag Compensator (SEMI F47을 만족하는 10kW급 3상 전압 새그 보상기 개발)

  • Chae, Seung-Woo;Cho, Hyun-Sik;Lee, Il-Yong;Kong, Se-Il;Han, Byung-Moon;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.198-204
    • /
    • 2012
  • 3-Phase voltage sag compensator protects a critical load from grid sags. The paper presents an algorithm and design of 3-phase voltage compensator. Compensator algorithm consists of a 3-phase voltage sag detection, thyrister commutation method and inverter output voltage control. The compensator satisfies SEMI F47 standard and 10kW 3-phase voltage sag compensator prototype is assembled. Validity of the proposed compensator is verified by simulation and experiment.

Voltage Sag Assessment Considering the Characteristics of Wind Power (풍력 발전 특성을 고려한 순간전압강하 평가)

  • Song, Young-Won;Park, Chang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1571-1577
    • /
    • 2012
  • This paper presents a method for assessing the voltage sag performance of power system involving wind power generation. Wind power generation is considered as one of the most desirable renewable energy sources. However, wind power generation have uncertain energy output and it is difficult to control the output. The existing methods of voltage sag assessment are not reflected the characteristics of wind power generation. Therefore, in order to more accurately assess the voltage sag performance, the probability of wind power operation is evaluated. In this paper, the probability is determined by combining the wind speed model with the output curve of wind turbine. The probability of wind power operation is reflected as a parameter in voltage sag assessment. The proposed method can provide more accurate results of voltage sag assessment for the case involving the wind power generation.

Stand-Alone Type Single-Phase Fuel Cells Micro-Source with ac Voltage Compensation Capability (교류전압 보상 기능을 갖는 독립형 단상 연료전지 마이크로 소스)

  • Jung, Young-Gook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • This paper proposes a stand alone type single-phase fuel cells micro-source with a voltage sag compensator for compensating the ac output voltage variations (sag or swell) of micro-source. The proposed micro-source is consist of a PEM(polymer electrolyte membrane) fuel cells simulator, a full bridge de converter, a 60Hz PWM(pulse width modulation) VSI(voltage source inverter), and a voltage sag compensator. Voltage sag compensator is similar to the configuration of hybrid series active power filter, and it is directly connected to micro-source through the injection transformer. Compensation algorithm of a voltage sag compensator adopts a single phase p-q theory. Effectiveness of the proposed the system is verified by the PSIM(power electronics simulation tool) simulation in the steady state and transient state which the proposed system is able to simultaneously compensate the harmonic current and source voltage sag or swell.

Three-Phase PWM-Switched Autotransformer Voltage-Sag Compensator Based on Phase Angle Analysis

  • Mansor, Muhamad;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • Many voltage sag compensators have been introduced, including the traditional dynamic voltage restorer (DVR), which requires an energy storage device but is inadequate for compensating deep and long-duration voltage sags. The AC-AC sag compensators introduced next do not require a storage device and they are capable of compensating voltage sags. This type of compensator needs an AC-AC converter to regulate the output voltage. Presented in this paper is a three-phase PWM-switched autotransformer voltage sag compensator based on an AC-AC converter that uses a proposed detection technique and PWM voltage control as a controller. Its effectiveness and capability in instantly detecting and compensating voltage sags were verified via MATLAB/Simulink simulations and further investigated through a laboratory prototype developed with a TMS320F2812 DSP as the main controller.

Single phase voltage sag compensator using single phase AC/AC chopper (단상 AC/AC 초퍼를 이용한 단상 Voltage Sag Compensator)

  • Kim, Dong-Kyu;Choi, Nam-Sup
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.142-143
    • /
    • 2014
  • 본 논문에서는 Buck type의 단상 AC/AC 초퍼를 이용한 단상 voltage sag compensator를 제안한다. 제안된 회로는 sag보상 동작 시 사용된 변압기의 누설리액턴스가 단상 PWM Buck AC/AC converter에 미치는 영향이 작아 동작효율이 높고, sag가 발생하지 않는 상태일 때 입력과 출력이 절연되는 장점이 있다. 본 논문에서는 제안된 회로의 동작 및 특성을 설명하고, 타당성을 입증하기 위해 PSIM으로 시뮬레이션 하였다.

  • PDF