• Title/Summary/Keyword: SAG2

Search Result 218, Processing Time 0.02 seconds

Western blot analysis of stray cat sera against Toxoplasma gondii and the diagnostic availability of monoclonal antibodies in sandwich-ELISA

  • Sohn, Woon-Mok;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.37 no.4
    • /
    • pp.249-256
    • /
    • 1999
  • A total of 198 sera from stray cats was assayed against Toxoplasma gondii antigen by western blot. Out of 198 sera assayed, 26 sera (13.1%) showed typical blot patterns against T gondii. When spotted by ELISA absorbance and indirect latex agglutination lest (ILAT) titer, all 26 cases were distributed over the cut-off value of ELISA whereas 24 cases (92.3%) were in the positive range of 1:32 or higher and 2 cases in negative range by ILAT. Among western blot negative 172 sera, 162 cases were negative in both ILAT and ELISA while 10 cases were reactive falsely such that three cases were ILAT positive with 1:32 titer and 9 cases were ELISA positive (2 cases overlapped). These 10 cases reacted peculiarly without typical binding pattern in Western blot. Sandwich-ELISA was performed with monoclonal antibodies (mAbs) of Tg563 (30 kDa, SAG 1), Tg505 (22 kDa, SAG2), Tg605 (43 kDa, SAG3), Tg556 (28 kDa, GRA2), Tg737 (32 kDa, GRA6). Tg695 (66 kDa, ROP2), Tg786 (42 kDa, ROP6), and Tg621 (32 kDa, anonymous but cytosolic) clone, respectively. All western blot-positive cases were in the positive range and negative cases in the negative range clearly. Among the 10 false reactive cases, 3 cases were in the positive range with one or more mAbs. All mAbs used in this study were confirmed to be specific to T. gondii infection as a standardized sandwich-ELISA to differentiate it from other pathogens.

  • PDF

A Study on the Geometry Change for the Increased Contact Wire Tension in the Pre-sagged Existing Catenary (사전 이도가 주어진 기설 전차선로에서 전차선 장력을 증가시켰을 때 전차선 기하학적 형상 변화 연구)

  • An, Seung-Hwa;Kim, Yoon-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.447-453
    • /
    • 2012
  • It is studied that the structure of the contact plane geometry of the contact wire would be changed when the contact wire tension is increased in the existing overhead contact lines for the purpose of improving the operation speed temporarily. In this paper, the dropper length formula which could be well applied to the pre-sagged catenary is reviewed first. Second, the changing amount of the pre-sag if the contact wire tension change from 20kN to 23kN or from 20kN to 25kN for the Gyeongbu HSL(high speed line) 49.5m catenary is evaluated by using of the self-written program in accordance with the dropper length formula. Moreover, the increasing tension and measuring the pre-sag change experiment in the Gyeongbu 2 HSL was conducted. The calculated data are compared with the measured data. As a result, it is found that the geometry change is very little and will not make the current collection performance deteriorated.

Real-Time RT-PCR on SAG1 and BAG1 Gene Expression during Stage Conversion in Immunosuppressed Mice Infected with Toxoplasma gondii Tehran Strain

  • Selseleh, Monavar;Modarressi, Mohammad Hossein;Mohebali, Mehdi;Shojaee, Saeedeh;Eshragian, Mohammad Reza;Selseleh, Mina;Azizi, Ebrahim;Keshavarz, Hossein
    • Parasites, Hosts and Diseases
    • /
    • v.50 no.3
    • /
    • pp.199-205
    • /
    • 2012
  • Toxoplasmic encephalitis is caused by reactivation of bradyzoites to rapidly dividing tachyzoites of the apicomplexan parasite Toxoplasma gondii in immunocompromised hosts. Diagnosis of this life-threatening disease is problematic, because it is difficult to discriminate between these 2 stages. Toxoplasma PCR assays using gDNA as a template have been unable to discriminate between an increase or decrease in SAG1 and BAG1 expression between the active tachyzoite stage and the latent bradyzoite stage. In the present study, real-time RT-PCR assay was used to detect the expression of bradyzoite (BAG1)- and tachyzoite-specific genes (SAG1) during bradyzoite/tachyzoite stage conversion in mice infected with T. gondii Tehran strain after dexamethasone sodium phosphate (DXM) administration. The conversion reaction was observed in the lungs and brain tissues of experimental mice, indicated by SAG1 expression at day 6 after DXM administration, and continued until day 14. Bradyzoites were also detected in both organs throughout the study; however, it decreased at day 14 significantly. It is suggested that during the reactivation period, bradyzoites not only escape from the cysts and reinvade neighboring cells as tachyzoites, but also converted to new bradyzoites. In summary, the real-time RT-PCR assay provided a reliable, fast, and quantitative way of detecting T. gondii reactivation in an animal model. Thus, this method may be useful for diagnosing stage conversion in clinical specimens of immunocompromised patients (HIV or transplant patients) for early identification of tachyzoite-bradyzoite stage conversion.

Phylogenetic relationships of Arthrospira strains inferred from 16S rRNA gene and cpcBA-IGS sequences

  • Choi, Gang-Guk;Ahn, Chi-Yong;Oh, Hee-Mock
    • ALGAE
    • /
    • v.27 no.2
    • /
    • pp.75-82
    • /
    • 2012
  • $Arthrospira$ $platensis$ and $Arthrospira$ $maxima$ are species of cyanobacteria used in health foods, animal feed, food additives, and fine chemicals. This study conducted a comparison of the 16S rRNA gene and $cpcBA$-intergenic spacer ($cpcBA$-IGS) sequences in $Arthrospira$ strains from culture collections around the world. A cluster analysis divided the 10 $Arthrospira$ strains into two main genotypic clusters, designated I and II, where Group I contained $A.$ $platensis$ SAG 86.79, UTEX 2340, $A.$ $maxima$ KCTC AG30054, and SAG 49.88, while Group II contained $A.$ $platensis$ PCC 9108, NIES 39, NIES 46, and SAG 257.80. However, although $A.$ $platensis$ PCC 9223 belonged to Group II-2 based on its $cpcBA$-IGS sequence, this strain also belonged to Group I based on its 16S rRNA gene sequence. Phylogenetic analyses based on the 16S rRNA gene and $cpcBA$-IGS sequences showed no division between $A.$ $platensis$ and $A.$ $maxima$, plus the 16S rRNA gene and $cpcBA$-IGS sequence clusters did not indicate any well-defined geographical distribution, instead overlapping in a rather interesting way. Therefore, the current study supports some previous conclusions based on 16S rRNA gene and $cpcBA$-IGS sequences, which found that $Arthrospira$ taxa are monophyletic. However, when compared with 16S rRNA sequences, $cpcBA$-IGS sequences may be better suited to resolve close relationships and intraspecies variability.

Isolation and Genotyping of Toxoplasma gondii in Brazilian Dogs

  • da Silva, Jamille Rodrigues;Maciel, Bianca Mendes;de Santana Souza Santos, Luana Karla Nogueira;Carvalho, Fabio Santos;de Santana Rocha, Daniele;Lopes, Carlos Wilson Gomes;Albuquerque, George Rego
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.3
    • /
    • pp.239-246
    • /
    • 2017
  • Strains of Toxoplasma gondii in Brazil are highly genetically diverse compared to strains from North America and Europe. Dogs are epidemiologically important because they act as sentinels for T. gondii infections in humans and are good indicators of environmental contamination. The aim of this study was to isolate and genetically characterize T. gondii strains from tissues of naturally infected Brazilian dogs. For this study, 21 blood samples were collected from dogs at the Zoonosis Control Centers of $Ilh{\acute{e}}us$ and Itabuna cities, Bahia, Brazil. The sera were examined for T. gondii antibodies using the indirect hemagglutination test. Brains and hearts of seropositive dogs were bioassayed in mice to isolate and characterize T. gondii parasites by PCR-RFLP using 10 genetic markers (SAG1, newSAG2, SAG3, BTUB, c22-8, c29-2, GRA6, PK1, APICO, and L358). However, T. gondii was isolated from only 4 (57.1%) dogs, designated TgDgBr6, 13, 17, and 21. All strains were virulent, causing clinical changes (rough hair coat, lethargy, and abdominal distention) and the death of all mice within 8-20 days after inoculation. Genetic analysis of these 4 T. gondii isolates revealed 4 distinct genotypes with different clonal lineage combinations (types I, II, and III) and 2 atypical alleles. Using PCR-RFLP with several markers, this study contributes to evaluations of the genetic diversity of strains circulating in Brazil.

Genetic characteristics of the Korean isolate KI -1 of Toxoplasma gondii

  • LIN Aifen;SHIN Eun-Hee;KIM Tae-Yun;PARK Jae-Hwan;GUK Sang-Mee;CHAI Jong-Yil
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.1 s.133
    • /
    • pp.27-32
    • /
    • 2005
  • Toxoplasma gondii tachyzoites were isolated from an ocular patient in the Republic of Korea and maintained in the laboratory (designated KI-1). In the present study, its genotype was determined by analyzing dense granule antigen 6 (GRA6) gene and surface antigen 2 (SAG2) gene as typing markers. Digestion of the amplification products of GRA6 and of the 5' and 3' ends of SAG2, respectively, with Mse I, Sau3A I, and Hha I, revealed that KI-1 is included in the genotype I, which includes the worldwide virulent RH strain. In addition, when the whole sequences of the coding regions of SAG1, rhoptry antigen 1 (ROP1), and GRA8 genes of KI-1 were compared with those of RH, minor nucleotide polymorphisms and amino acid substitutions were identified. These results show that KI-1 is a new geographical strain of T. gondii that can be included in the genotype I.

Parsing the Wh-Interrogative Construction in Korean

  • Yang, Jaehyung;Kim, Jong-Bok
    • Language and Information
    • /
    • v.17 no.2
    • /
    • pp.51-66
    • /
    • 2013
  • Korean is a wh-in-situ language where the wh-expression stays in situ with an obligatory Q-particle marking its interrogative scope. This paper briefly reviews some basic properties of the wh-question construction in Korean and shows how a typed feature structure grammar, HPSG (Pollard and Sag 1994, Sag et al. 2003), together with the notions of 'type hierarchy' and 'constructions', can provide a robust basis for parsing the wh-construction in the language. We show that this system induces robust syntactic structures as well as enriched semantic representations for real-time applications such as machine translation, which require deep processing of the phenomena concerned.

  • PDF

A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads (컴퓨터 부하의 직렬 동조 필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구)

  • Seo, Beom-Gwan;Kim, Kyoung-Chul;Lee, Geun-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.460-461
    • /
    • 2006
  • Computer Loads can be found in all of modern society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as disruption in computer performance. A series resonant filter is very effective in harmonic reduction for personal computer loads. Voltage sags are short duration reductions in rms voltage. The main causes of voltage sags are faults, motor starting, and transformer energizing. Personal computers are another example of devices sensitive to voltage sags. A serious voltage sag at the terminals way lead mis-operation of the equipment. This paper presents an in depth analysis to evaluate the effect of harmonics reduction based on the IEC 61000-3-2 and the effect of voltage sag using ITI curve by applying a series resonant filter for personal computer loads.

  • PDF

Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire (통전 중 산불에 노출된 가공송전선의 온도 및 장력 변화 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.366-371
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperatures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

Development of High-Performance Single-Phase Line-Interactive Dynamic Voltage Restorer (고성능 단상 선로응동형 DVR(Dynamic Voltage Restorer))

  • Bae, Byung-Yeol;Lee, Dong-Geun;Kwak, No-Hong;Park, Sang-Ho;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1947-1954
    • /
    • 2007
  • This paper describes the development of a high-performance single-phase line-interactive Dynamic voltage Restorer, which is composed of an H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.