• Title/Summary/Keyword: S2S Radiation

Search Result 2,834, Processing Time 0.03 seconds

Radiotherapeutic Result of Waldeyer's Ring Lymphoma (Waldeyer's Ring 임파종 : 방사선 치료의 결과)

  • Kim, Ju-Ree;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.261-267
    • /
    • 1990
  • Twenty patients with biopsy-proven Waldeyer's ring lymphoma were treated with radiotherpy between 1984 and 1990 at the Department of Radiation Therapy, Inje University Paik Hospital and seventeen evaluable patients were analysed retrospectively. Dose of radiation ranged from 35 to 50 Gy to Waldeyer's ring structure with an additional 5 and 10 Gy boost dose to the primary site. The lower cervical nodes received 35 to 60 Gy. The median follow-up period was 24 months (range;9 to 80 months). The 5-year overall survival rate was $50.2{\%}$ and 5-year disease free survival rate was $47.1{\%}$. The final local control rate was $82.4{\%}$. The relapse developed average 10 months after treatment. Most of relapses were systemic ($87.5{\%}$). The patients with stage I disease fared better than advance stage. The favorable histology of lymphoma showed better prognosis than unfavorable histology. There was no significant difference in survival rate between radiotherapy alone and combination of chemotherapy and radiotherapy in early stage lymphomas. But of the patients with advanced stage, those who received chemotherapy and radiotherapy had better prognosis than those treated with radiotherapy alone.

  • PDF

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

The single institutional outcome of postoperative radiotherapy and concurrent chemoradiotherapy in resected non-small cell lung cancer

  • Lee, Hyo Chun;Kim, Yeon Sil;Oh, Se Jin;Lee, Yun Hee;Lee, Dong Soo;Song, Jin Ho;Kang, Jin Hyung;Park, Jae Kil
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.147-155
    • /
    • 2014
  • Purpose: This study was conducted to observe the outcomes of postoperative radiotherapy (PORT) with or without concurrent chemotherapy in resected non-small cell lung cancer (NSCLC) in single institution. Materials and Methods: From 2002 to 2013, 78 patients diagnosed with NSCLC after curative resection were treated with radiotherapy alone (RT, n = 48) or concurrent chemoradiation (CCRT, n = 30). The indications of adjuvant radiation therapy were N2 node positive (n = 31), close or involved resection margin (n = 28), or gross residual disease due to incomplete resection (n = 19). The median radiation dose was 57.6 Gy (range, 29.9 to 66 Gy). Results: Median survival time was 33.7 months (range, 4.4 to 140.3 months). The 5-year overall survival (OS) rate was 49.5% (RT 46% vs. CCRT 55.2%; p = 0.731). The 3-year disease-free survival rate was 45.5% (RT 39.4% vs. CCRT 55.3%; p = 0.130). The 3-year local control rate was 68.1% (RT 64.4% vs. CCRT 77.7%; p = 0.165). The 3-year DMFS rate was 56.1% (RT 52.6% vs. CCRT 61.7%; p = 0.314). In multivariate analysis, age ${\geq}66$ years and pathologic stage III were significant poor prognostic factors for OS. Treatment failure occurred in 40 patients. Four patients had radiologically confirmed grade 3 radiation pneumonitis. Conclusion: In NSCLC, adjuvant RT or CCRT after curative surgery is a safe and feasible modality of treatment. OS gain was seen in patients less than 66 years. Postoperative CCRT showed a propensity of achieving better local control and improved disease-free survival compared to RT alone according to our data.

Radiation Damage of Semiconductor Device by X-ray (엑스선에 의한 반도체 소자의 방사선 손상)

  • Kim, D.S.;Hong, H.S.;Park, H.M.;Kim, J.H.;Joo, K.S.
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.110-117
    • /
    • 2015
  • Recently, Due to the increased industry using radiation inspection equipment in the semiconductor, this demand of technology research is increasing. Although semiconductor inspection equipment is using low energy X-ray from 40 keV to 120 keV, Studies of radiation damage about the low energy X-ray are lacking circumstance in our country. Therefore, It is study that BJT (bipolar junction transistor) of one type of semiconductor elements are received radiation damage by low energy X-ray. BJT were used to the NXP semiconductor company's BC817-25 (NPN type), and Used the X-ray generator for the irradiation. Radiation damage of BJT was evaluated that confirm to analyse change of collector-emitter voltage of before and after X-ray irradiation when current gain fixed to 10. X-ray generator of tube voltage was setting 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp and irradiation time was setting 180s, 360s, 540s into 180s intervals. As the result, We confirmed radiation damage in BJT by low energy X-ray under 120 keV energy, and Especially the biggest radiation damage was appeared at the 80 kVp. It is expected that ELDRS (enhanced low dose rate sensitivity) phenomenon occurs on the basis of 80 kVp. This studies expect to contribute effective dose administration of semiconductor inspection equipment using low energy X-ray, Also Research and Development of X-ray filter.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (Lung Cancer의 Stereotactic Radiosurgery시 Respiratory Gating system의 유용성에 대한 연구)

  • Song Heung Kwon;Kim Min Su;Yang Oh Nam;Park Cheol Su;Kwon Kyung Tae;Kim Jeong Man
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.13-17
    • /
    • 2005
  • Introduction : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was peformed using the Respiratory gating system and its clinical effectiveness was evaluated. Methode and Materials : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Result : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient $\#$1, motion of GTV was reduced to 2.6 mm in treatment phases ($30\%\~60\%$), while that was 9.4 mm in full phases ($0\%\~90\%$) and for patient $\#$2, it was reduced to 2.3 mm in treatment phases ($30\%\~70\%$), while it was 11.7 mm in full phases ($0\%\~90\%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy

  • Park, So Hyun;Choi, Jinhyun;Kim, JinSung;Ahn, Sohyun;Kim, Min Joo;Lee, Ho;Choi, Seo Hee;Park, Kwangwoo
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The $TomoTherapy^{(R)}$ beam-delivery method creates helical beam-junctioning patterns in the dose distribution within the target. In addition, the dose discrepancy results in the particular region where the resonance by pattern of dose delivery occurs owing to the change in the position and shape of internal organs with a patient's respiration during long treatment times. In this study, we evaluated the dose pattern of the longitudinal profile with the change in respiration. The superior-inferior motion signal of the programmable respiratory motion phantom was obtained using AbChes as a four-dimensional computed tomography (4DCT) original moving signal. We delineated virtual targets in the phantom and planned to deliver the prescription dose of 300 cGy using field widths of 1.0 cm, 2.5 cm, and 5.0 cm. An original moving signal was fitted to reflecting the beam delivery time of the $TomoTherapy^{(R)}$. The EBT3 film was inserted into the phantom movement cassette, and static, without the movement and with the original movement, was measured with signal changes of 2.0 s, 4.0 s, and 5.0 s periods, and 2.0 mm and 4.0 mm amplitudes. It was found that a dose fluctuation within ${\pm}4.0%$ occurred in all longitudinal profiles. Compared with the original movement, the region of the gamma index above 1 partially appeared within the target and the border of the target when the period and amplitude were changed. Gamma passing rates were 95.00% or more. However, cases for a 5.0 s period and 4.0 mm amplitude at a field width of 2.5 cm and for 2.0 s and 5.0 s periods at a field width of 5.0 cm have gamma passing rates of 92.73%, 90.31%, 90.31%, and 93.60%. $TomoTherapy^{(R)}$ shows a small difference in dose distribution according to the changes of period and amplitude of respiration. Therefore, to treat a variable respiratory motion region, a margin reflecting the degree of change of respiration signal is required.

Comparison with ABCHES and Abdomen Compression Device in Respirational Radiation Therapy on Patients in Hepatocellular Carcinoma (간세포암 환자에서 ABCHES와 복부압박장비의 적용한 호흡동조방사선 치료의 유용성 비교)

  • Cho, Yoon-Jin;Byun, Sang-Joon;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.395-402
    • /
    • 2012
  • 4D-Radiation Therapy is the optimal treatment to track moving organs(tumor) and give the appropriate prescription dose to tumor and low radiation dose to normal tissue surrounding tumor volume. The ABCHES is a 4DRT devices maintaining shallow breathing to patients. It allows the tumor's movement was minimize. Meanwhile, Abdominal compression device is limited the breath compressing abdomen on patients. In this paper we will quantitative analysis the movement of tumor on only ABCHES versus ABCHES with Abdomal compression device and Analysis tumor dose and normal tissue's dose by Dose Volume Histogram on two parts. The result of Comparision ABCHES and ABCHES with Abdominal compression device, SI(Superior-Inferior) direction, AP(Anterior-Posterior) direction and LR(Left-Right) direction was limited 1.0 mm, 0.2 mm, 0.2 mm(average). and also reduction rate of voluume in HPTV was $16{\pm}2%$, and LPTV was $15.8{\pm}0.8%$ under only using ABCHES and ABCHES with compression. The analysis dose volume histogram was more radiation dose in ABCHES and abdominal compression device than only using ABCHES, and less normal tissue-ipsilateral lung, whole lung, kidney-dose in ABCHES and abdominal compression device than only using ABCHES. The overall analysis was ABCHES with abdominal compression better than only using ABCHES method. In hereafter it will be studies that limitation of ABCHES and abdomonal compression device. In other words, patient's discomfort on compression intensity, method of application on patient with inaccurate respiration cycle.

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

Radiation-induced Apoptosis is Differentially Modulated by PTK Inhibitors in K562 Cells (K562 백혈병 세포주에서 방사선에 의해 유도되는 Apoptosis에 미치는 PTK Inhibitors의 영향)

  • Lee Hyung Sik;Moon Chang Woo;Hur Won Joo;Jeong Su Jin;Jeong Min Ho;Lee Jeong Hyeon;Lim Young kin;Park Heon Joo
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2000
  • Purpose :The effect of PTK inhibitors (herbimycin A and genistein) on the induction of radiation-induced apoptosis in Ph-positive KS62 leukemia cell line was investigated. Materials and Methods :K562 cells in exponential growth phase were irradiated with a linear accelerator at room temperature. For 6 MV X-ray irradiation and drug treatment, cultures were initiated at 2×106 cells/mL. The cells were irradiated with 10 Gy. Stock solutions of herbimycin A and genistein were prepared in dimethyl sulphoxide (DMSO). After incubation at 37$^{\circ}C$ for 0$\~$48 h, the extent of apoptosis was determined using agarose gel electrophoresis and TUNEL assay. The progression of cells through the cell cycle after irradiation and drug treatment was also determined with flow cytometry. Western blot analysis was used to monitor bel-2, bel-X$_{L}$ and bax protein levels. Results :Treatment with 10 Gy X-irradiation did not result in the induction of apoptosis. The HMA alone (500 nM) also failed to induce apoptosis. By contrast, incubation of K562 cells with HMA after irradiation resulted in a substantial induction of nuclear condensation and fragmentation by agarose gel electro-phoresis and TUNEL assay. Genistein failed to enhance the ability of X-irradiation to induce DNA fragmentation. Enhancement of apoptosis by HMA was not attributable to downregulation of the bel-2 or bel-X$_{L}$ anti-apoptotic proteins. When the cells were irradiated and maintained with HMA, the percentage of cells in G2/M phase decreased to 30$\~$40$\%$ at 48 h. On the other hand, cells exposed to 10 Gy X-irradiation alone or maintained with genistein did not show marked cell cycle redistribution. Conclusion : We have shown that nanomolar concentrations of the PTK inhibitor HMA synergize with X-irradiation in inducing the apoptosis in Ph (+) K562 leukemia cell line. While, genistein, a PTK inhibitor which is not selective for p210$^{bcr/abl}$ failed to enhance the radiation induced apoptosis in KS62 cells. It is unlikely that the ability of HMA to enhance apoptosis in K562 cells is attributable to bel-2 family. It is plausible that the relationship between cell cycle delays and cell death is essential for drug development based on molecular targeting designed to modify radiation-induced apoptosis.

  • PDF