• Title/Summary/Keyword: S/N Ratio(Signal to Noise Ratio)

Search Result 187, Processing Time 0.024 seconds

Design of a nonlinear ADC encoder to reduce the conversion errors in DBNS (DBNS 변환오차를 고려한 비선형 ADC 엔코더 설계)

  • Woo, Kyung-Haeng;Choi, Won-Ho;Kim, Jong-Soo;Choi, Jae-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.249-254
    • /
    • 2013
  • A fast multiplier and ADC are essential to process the analog signals in real time. The double-base number system(DBNS) is known as an efficient method for this purpose. The DBNS uses the numbers 2 and 3 as the base numbers simultaneously. The system has an advantage of fast multiplication, less chip area, and low power consumption compared to the binary multiplier. However, the inherent errors of the log number's intrinsic tolerance in DBNS are accumulated in a FIR digital filter, so the signal-to-noise ratio(SNR) has a tendency to be degraded. In this paper, the nonlinear encoder of ADC is designed to compensate the accumulated errors of DBNS by analysing the error distributions of various filter coefficients. The new ADC does not sacrifice its own advantages because the encoder circuits are modified only. The experiments were done with an FIR filters those were designed to have -70dB of SNR in stop band. The proposed nonlinear ADC encoder could drop the SNR to -45dB in stop band, in contrast to -35dB with the linear encoder.

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Analysis of Flavonoids in Concentrated Pomegranate Extracts by HPLC with Diode Array Detection

  • Lee, Jeong-Hwan;Kim, Seung-Deok;Lee, Ja-Young;Kim, Kyung-Nam;Kim, Hyun-Su
    • Food Science and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.171-174
    • /
    • 2005
  • Three flavonoid compounds - quercetin, luteolin, and kaempferol - were analyzed from two commercially available concentrated pomegranate extracts produced in Turkey and Italy, respectively. The samples were freeze-dried and hydrolyzed by 0.4 M hydrochloric acid in 50% ethanol at $80^{\circ}C$. HPLC (high-performance liquid chromatography) with DAD (diode array detection) at a wavelength of 260 nm was used for the detection of the three flavonoids. The detection limits of the three compounds were in hundreds of picograms and the signal-to-noise ratio ranged from 4 to 5: quercetin: >308 pg, s/n=4.0; luteolin: >262 pg, s/n=4.5; kaempferol: >688 pg, s/n=5.0. Quercetin, but not luteolin and kaempferol, was detected in the both pomegranate extracts. The concentrations of quercetin were $49.7\;{\mu}g/g$ and $27.7\;{\mu}g/g$ in the two pomegranate extracts made in Turkey and Italy, respectively.

Low Power SAR ADC with Series Capacitor DAC (직렬 커패시터 D/A 변환기를 갖는 저전력 축차 비교형 A/D 변환기)

  • Lee, Jeong-Hyeon;Jin, Yu-Rin;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.90-97
    • /
    • 2019
  • The charge redistribution digital-to-analog converter(CR-DAC) is often used for successive approximation register analog-to-digital converter(SAR ADC) that requiring low power consumption and small circuit area. However, CR-DAC is required 2 to the power of N unit capacitors to generate reference voltage for successive approximation of the N-bit SAR ADC, and many unit capacitors occupy large circuit area and consume more power. In order to improve this problem, this paper proposes SAR ADC using series capacitor DAC. The series capacitor DAC is required 2(1+N) unit capacitors to generate reference voltage for successive approximation and charges only two capacitors of the reference generation block. Because of these structural characteristics, the SAR ADC using series capacitor DAC can reduce the power consumption and circuit area. Proposed SAR ADC was designed in CMOS 180nm process, and at 1.8V supply voltage and 500kS/s sampling rate, proposed 6-bit SAR ADC have signal-to-noise and distortion ratio(SNDR) of 36.49dB, effective number of bits(ENOB) of 5.77-bit, power consumption of 294uW.

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

The effect of electrodes' allocation on single dipole source tracing in EEG (전극 배치가 EEG의 Single Dipole Source 추정에 끼치는 영향에 관한 연구)

  • Park, K.B.;Kim, D.W.;Bae, B.H.;Kim, S.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.131-133
    • /
    • 1994
  • 뇌전위 측정에 의해 흥분 뉴런군의 위치를 추정하는 source localization problem은 Evoked Potential 해석법에 있어서 매우 중요한 의미를 갖는다. 이번 논문에서는 EEG실험에서의 전극 배치가 S/N(signal to noise ratio)과 추정 오차 사이에 어떤 영향을 미치는 가를 Monte Carlo 시뮬레이션으로 조사하였다. 머리 모델은 3중 구각 모델을 사용하였고 이론 이용하여 forward problem을 계산하였다. 쌍극자 파라미터를 minimization 하는 문제는 simplex method를 이용하여 계산하였다. 컴퓨터 시뮬레이션 결과, 특이한 점은 전극의 밀도와 입체각에 의해 쌍자 파라미터 오차가 변화했다는 사실이다. 이것은 곧바로 전극 배치와 연관이 된다. 실제 EEG 실험에서 전극 배치를 어떻게 했는가에 따라 그에 따른 오차가 변화한다. 이러한 오차의 원인을 제거하기 위해서 새로운 전극 배치를 모델링하여 기존의 전극 배치와 비교해 보았다. 그 결과 전극 밀도와 입체각에 대한 오차를 크게 줄일 수 있었다.

  • PDF

High Resolution AR Spectral Estimation by Principal Component Analysis (Principal Componet Analysis에 의한 고 분해능 AR 모델링과 스텍트럼 추정)

  • 양흥석;이석원;공성곤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.11
    • /
    • pp.813-818
    • /
    • 1987
  • In this paper, high resolution spectral estimation by AR modelling and principal comonent analysis is proposed. The given data can be expanded by the eigenvectors of the estimated covariance matrix. The eigenspectrum is obtained for each eigenvector using the Autoressive(AR) spectral estimation technique. The final spectrum estimate is obtained by weighting each eigenspectrum with the corresponding eigenvalue and summing them. Although the proposed method increases in computational complexity, it shows good frequency resolution especially for short data records and narrow-band data whose signal-to-noise ratio is low.

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kyung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF