• Title/Summary/Keyword: Rotation Center

Search Result 981, Processing Time 0.036 seconds

A Study on the Cutting Optimal Power Requirements of Fast Growing Trees by Circular Saw (원형톱에 의한 속성수 절단 적정 소요동력 산정에 관한 연구)

  • Choi, Yun Sung;Kim, Dae Hyun;Oh, Jae Heun
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.3
    • /
    • pp.402-407
    • /
    • 2014
  • In this study, Italy poplar(Populus euramericana) was selected for test specimen to measure cutting power when it harvested. The experiment has been controlled as three levels of feed rate (0.41, 1.25 and 2.5 m/s), sawing speed (800, 1,000 and 1,200 rpm), and the five levels of root collar diameter (50, 70, 90 and 110, 130 mm). The harvested volume after 3 years (root collar diameter 50 mm) was 10.5 tons, which falls short of the target amount of biomass is 20~30 ton/ha. In addition, the biomass amount of diameter 90 and 110 mm which reached the target amount were estimated to be 23.5 and 32.5 ton/ha respectively. As a result of experiment, it was found out that power of 128.2 and 175.8 W are consumed in case of cutting with the feed rate of 0.41m/s and minimum sawing speed (800 rpm) respectively. With the working area of 0.3 ha/h, it is considered to present working capacities of 16.5 and 22.8 ton/h respectively. The power consumed at the feed rate of 1.25 m/s is estimated to be 113.8 and 153.7W respectively and working capacity in a working area of 1 ha/h is estimated to be 23.5 and 32.5 ton/h. The power consumed at the feed rate of 2.5 m/s is estimated to be 119.8 and 166.9 W respectively and working capacity in a working area of 2 ha/h is estimated to be 47.0 and 65.5 ton/ha respectively. Therefore, the power source of harvest machine at the feed rate of 1.25, 2.50 m/s and sawing speed of 800 rpm shall be selected as it can process the target amount of estimated biomass.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Patient Satisfaction and Perception on Nutritional Counseling Services Quality (영양 상담서비스 품질에 대한 환자의 만족도와 인식조사)

  • Choi, Ki Bo;Lee, Song Mi;Lee, Seung Min;Lee, Eun;Park, Mi Sun;Park, Yoo Kyoung;Cha, Jin A;Lyu, Eun Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The objective of this study was to analyze patient satisfaction and perception of nutritional counseling services quality. A patient satisfaction and perception survey was conducted for 1,095 patients from 43 tertiary hospitals and 20 general hospitals. The number of returned questionnaires was 656 (response rate: 60.0%). Data from 633 questionnaires were analyzed after the questionnaires with unanswered items were excluded. Five domains were identified from the result of the factor analysis using the maximum likelihood and oblique rotation. The five domains were named empathy, responsiveness, tangibles, reliability, and skill and specialty. Patient perception mean score of nutritional counseling was 4.54/5.00. Patient satisfaction scores were significantly higher in empathy (P<0.001), responsiveness, and skill and specialty (P<0.01) with a college or graduate school education than in patients with a middle school education. There was no statistically significant difference between satisfaction scores in tertiary hospitals and those in general hospitals, but patients in capital hospitals reported significantly higher scores than their local counterparts in empathy, responsiveness, reliability, skill and specialty (P<0.001), and tangibles (P<0.05). In responsiveness, significantly higher (P<0.01) scores were observed in patients who received nutritional counseling only once compared to patients who received counseling two times. Patients perception of nutritional counseling services was significantly correlated with their satisfaction of five domains, reliability (r=0.721), responsiveness (r=0.697), empathy (r=0.690), skill and specialty (r=0.678), and tangibles (r=0.622).

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Resistance and Susceptibility of Diamondback Moth, Plutella xylostella Strains Collected from Different Region in Korea to Bacillus thuringiensis (국내 지역별 채집계통 및 감수성계통 배추좀나방에 대한 Bacillus thuringiensis 제품의 생물활성 비교)

  • Kim, Young-Rim;Cho, Min-Su;Oh, Se-Mun;Kim, Sung-Woo;Youn, Young-Nam;Yu, Yong-Man
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.2
    • /
    • pp.123-132
    • /
    • 2010
  • Six populations of the diamondback moth, Plutella xylostella, were collected from the different national areas for resistance and reared in laboratory for two sensitive population. These populations of P. xylostella were examined the developed resistance against commercial products of Bacillus thuringiensis. There were 3 products with B. thuringiensis subsp. kurstaki including Tyuneup$^{(R)}$, Thuricide$^{(R)}$ and Geumulmang$^{(R)}$ and 2 products with B. thuringiensis subsp. aizawai including Tobagi$^{(R)}$ and Scorpion$^{(R)}$. The sensitive population of diamondback moths were provided from National Academy of Agricultural Science (NP) and Highland Agriculture Research Center (GR population) and field populations were caught from 6 different national areas. Resistance against Tyuneup$^{(R)}$ was developed 4.8 and 2.5 times in SP and HS compared with GR population of diamondback moth, respectively. In case of Geumulmang$^{(R)}$, it was developed 9.9 and 6.8 times in SP and NM population compared with NP population, respectively. Otherwise, Tobagi$^{(R)}$ was showed higher resistance in HS than any other population compared with GR population, however, Scorpion$^{(R)}$ that is a same strain with Tobagi$^{(R)}$, was showed only double resistance to SP population. It was supposed that the development of resistance to B. thuringiensis might be caused by the continuous application of the specific commercial product at the specific area. So, we need to use the commercial products of B. thuringiensis in rotation with different B. thuringiensis strains. In the other hand, when HS population with highest resistance were reared in laboratory, their resistance ratio was rapidly dropped to 1.1 times at second generation. We have to examined the resistance mechanism of the diamondback moth to B. thuringiensis strains.

A Comparison of pre and post-surgical characteristics in skeletal Class III malocclusion patients using counterpart analysis (구조적 대응체 분석법에 의한 골격성 II급 부정교합 환자의 악교정 수술전후의 비교)

  • Sohn, Byung-Wha;Kyung, Seung-Hyun;Kim, Beom-soo
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.93-107
    • /
    • 2004
  • Enlow's counterpart analysis explains the complex with anatomic and developmental characteristics where craniofacial aspect of Individuals has been developed. Counterpart analysis does not compare individual measurement with the normal value from the average of majority but analyzes by comparison of values that each individual has. In this study we examined surgical changes in skeletal Class III malocclusion patients(male 40, female 40) and compared them with normal occlusion patients using counterpart analysis. The results indicated that : 1. Skeletal anterior-posterior discrepancy was relieved by shortening of the ramus width(B3). 2. The ramus alignment(R3, R4) was displaced posteriorly and the occlusal plane angle(R5) was rotated clockwise. 3. Skeletal Class III pattern was relieved in the post-operative group, but differences in the level of the cranium(R1, R2) was remaining compared to the normal occlusion patients. 4. In the comparison of surgery methods, the two-jaw surgery group presented changes In the maxillary length(A4), ramus alignment(R3, R4) and occlusal plane angle(R5) compared to the one-jaw surgery group, but the differences were not significant. In the past study about Korean skeletal Class m patients, the skeletal characteristics are upward backward rotation of the cranial base, posterior displacement of the maxilla, forward inclination of the ramus and lengthening of the mandibular body, but in this study, skeletal Class m pattern was relieved by shortening of the ramus width and maxillary advancement by orthognathic surgery, because orthognathic surgery is usually performed on limited areas in the maxilla and the mandible.

Minimally Invasive Repair of Pectus Excavatum Based on the Nuss Principle: An Evolution of Techniques and Early Results on 322 Patients (Nuss 술식에 기초한 누두흉의 최소 침습 수술: 수술 수기의 개발 및 322예의 조기 성적)

  • Park, Hyun-Joo;Song, Cheol-Min;Her, Keun;Jeon, Cheol-Woo;Chang, Won-Ho;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.164-174
    • /
    • 2003
  • Background: The Nuss procedure is a recently developed technique for minimally invasive repair of pectus excavatum using a metal bar. Although its technical simplicity and cosmetic advantages are remarkable, applications have been limited to children with standard pectus excavatum. We report a single center experience of the technique that has been evolving in order to correct asymmetric pectus configurations and adult patients. Material and Method: Between August 1999 and June 2002, 322 consecutive patients un-derwent repair by the Nuss technique and its modifications. Among them, 71 (22%) were adults. For the precise correction, morphology of the pectus was classified as symmetric and asymmetric types. Asymmetric type was subdivided into eccentric and unbalanced types. In repair, differently shaped bars were applied to individual types of pectus to achieve symmetric correction. Result: Symmetric type was 57.5% (185/322) and asymmetric type was 42.5% (137/322). Eccentric, unbalanced, and combined types were 71, 47 and 19, respectively, Major modifications were bar shaping and fixation. In asymmetric group, different shapes of asymmetric bars were applied (n=125, 38.8%). For adult patients, double bar or compound bar technique was used (n=51, 15.8%). To prevent bar rotation, multipoint wire fixations to ribs were used. Major postoperative complications were pneumothorax (n=24, 7.5%) and bar displacement (n=11, 3.4%). 42 patients had bar removal 2 years after the initial procedure. Conclusion: The Nuss procedure is safe and effective. Modifications of the techniques in accordance with precise morphological classification enabled the correction of all variety of pectus excavatum including asymmetric types and adult patients.

Skeletal relapse and dental change during intermaxillary fixation after mandibular setback (외과적 하악 후퇴술 후 악간고정기간 중의 골격성 재발과 치열의 변화)

  • Chang, Chong-On
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.457-466
    • /
    • 1999
  • It has been reported that skeletal relapse and dental change after mandibular setback do occur not only after intermaxillary fixation(IMF) removal but also during IMF The side effects of skeletal relapse during IMF have clinical importance because they can cause many Postoperative orthodontic Problems. Generally, the Prevention of solid union between segments, compensatory tooth movement, anterior openbite, etc. have been cited as the side effects of jaw displacement. The purpose of this study was to evaluate the skeletal relapse and dental change during IMF. The material consisted of 28 patients who were treated by BSSRO(bilateral sagittal split ramus osteotomy), wire osteosynthesis, IMF for correction of mandibular prognathism. Through cephalometric analysis, the amount and direction of surgical movement, skeletal relapse and dental change during IMF were measured. The correlation between surgical movement and skeletal relapse, between skeletal relapse and dental changes were evaluated. The following conclusions were obtained; 1. Distal segment was repositioned backward and upward, proximal segment showed clockwise rotation during surgery. 2. During ]m, anterior portion of distal segment was displaced backward and posterior portion was displaced upward. Proximal segment was displaced upward with forward movement of p-Go(gonion of proximal segment). Backward surgical movement of p-GO was significantly correlated with forward displacement of p-Go. 3. Overjet and overbite were not changed during IMF. The compensatory tooth movements during IMF were characterized by retroclination of upper incisors md retroclination, extrusion of lower incisors. These compensatory tooth movements had statistically significant correlation with upward displacement of d-Go (gonion of distal segment).

  • PDF

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF