• Title/Summary/Keyword: Rotation Center

Search Result 985, Processing Time 0.043 seconds

A Semi-fragile Watermarking Algorithm of 3D Mesh Model for Rapid Prototyping System Application (쾌속조형 시스템의 무결성 인증을 위한 3차원 메쉬 모델의 Semi-fragile 워터마킹)

  • Chi, Ji-Zhe;Kim, Jong-Weon;Choi, Jong-Uk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.17 no.6
    • /
    • pp.131-142
    • /
    • 2007
  • In this paper, semi-fragile watermarking algorithm was proposed for the application to RP(Rapid Prototyping) system. In the case of the perceptual change or distortion of the original one, the prototype product will be affected from the process because the RP system requires the high precision measure. Therefore, the geometrical transformations like translation, rotation and scaling, the mesh order change and the file format change are used in the RP system because they do not change the basic shapes of the 3D models, but, the decimation and the smoothing are not used because they change the models. The proposed algorithm which is called semi-fragile watermarking is robust against to these kinds of manipulations which preserve the original shapes because it considers the limitations of the RP system, but fragile against to the other manipulations which change the original shapes. This algorithm does not change the model shapes after embedding the watermark information, that is, there is no shape difference between the original model and the watermarked model. so, it will be useful to authenticate the data integrity and hide the information in the field of mechanical engineering which requires the high precision measure.

A Study on Quality Improvement and Verification of Recycled Coarse Aggregate for Concrete Using an Impact Crusher with Radial Rotation (방사형 회전이 추가된 임팩트 크러셔를 이용한 콘크리트용 순환굵은골재 품질향상 및 검증 연구)

  • Jeon, Duk-Woo;Kim, Yong-Seong;Jeon, Chan-Soo;Choi, Won-Young;Cho, Won-Ig
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.133-142
    • /
    • 2022
  • The purpose of this study is to develop an impact crusher with a radial rotating plate installed at the bottom, which is a shock absorber that can produce high-quality recycled coarse aggregate for concrete and to verify the effect of improving the quality performance of recycled coarse aggregate and its applicability through concrete tests. As a result, it showed improved quality in all items such as absolute dry density, absorption rate, abrasion resistance, Particle shape judgment rate, amount lost in the 0.08 mm sieve passing test, alkali aggregate reaction, clay mass, stability, and impurity content, and it was found to meet the criteria of recycled aggregate quality standards. In addition, the air volume and slump of concrete to which recycled coarse aggregate is applied meet all domestic standards. According to the test results of the compressive strength characteristics by age of concrete according to the mixing ratio of the recycled coarse aggregate, it was confirmed that the mixing ratio of the recycled coarse aggregate was applicable up to 60 %.

Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study

  • Lu Yin;Lijuan Du;Yuanzi Li;Yang Xiao;Shiquan Zhang;Huizi Ma;Wen He
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1841-1849
    • /
    • 2021
  • Objective: To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods: SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results: The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of -29.13° ± 3.79° and -25.65° ± 3.39°, respectively, vs. -21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = -0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion: The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.

Effects of Ridge Width on Growth and Yield of Proso Millet (Panicum miliaceum L.) in Paddy-Upland Rotation Field (답전윤환지에서 이랑너비에 따른 기장의 생육특성 및 수량)

  • Yoon, Dong-Kyung;Oh, Seung-Ka;Lee, Byung-Jin;Chun, Hyun-Sik;Jung, Ki-Youl;Kang, Hang-Won;Jeon, Seung-Ho;Cho, Young-Son
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.2
    • /
    • pp.217-223
    • /
    • 2015
  • This study was conducted to serve as a basis for establishing a stable production of proso millet on the rotational paddy-upland field by looking out the physicochemical and moisture characteristics of soil and the growth characteristics of proso millet by ridge width. Plant height showed Manhongchal was the smallest 71.3 cm in 240 cm wide of ridge in the first year, Ibeakchal was the highest 69.7 cm in 60 cm wide in the second year, Hwanggeumchal was the highest 72.8 cm in 60 cm wide in the first year. The retention time of the excess water in the soil during cultivation was extended wider the width of ridge. The variation width of the water content was higher by the wider the width of ridge. Yield components showed the longest ear length were 35.1 cm of Manhongchal, 34.8 cm of Ibeakchal in 60 cm wide of ridge in the first year. As the width of ridge extended, ear weight of all variety increased. 1,000 seed weight of the 60 cm wide of ridge was Manhongchal 6.8%, Ibeakchal 46.2% heavier than the 240 cm wide of ridge. Yield showed Manhongchal 221, Ibeakchal 223, Hwanggeumchal $225kg{\cdot}10a^{-1}$ in 60 cm wide of ridge in the first year. The similar pattern of amount showed Manhongchal 278, Ibeakchal 221, Hwanggeumchal $200kg{\cdot}10a^{-1}$ in 60 cm wide of ridge in the second year. This showed Manhongchal 103%, Ibeakchal 119%, Hwanggeumchal 85.2% was more than the 240 cm wide of ridge.

A Study on the Cutting Optimal Power Requirements of Fast Growing Trees by Circular Saw (원형톱에 의한 속성수 절단 적정 소요동력 산정에 관한 연구)

  • Choi, Yun Sung;Kim, Dae Hyun;Oh, Jae Heun
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.3
    • /
    • pp.402-407
    • /
    • 2014
  • In this study, Italy poplar(Populus euramericana) was selected for test specimen to measure cutting power when it harvested. The experiment has been controlled as three levels of feed rate (0.41, 1.25 and 2.5 m/s), sawing speed (800, 1,000 and 1,200 rpm), and the five levels of root collar diameter (50, 70, 90 and 110, 130 mm). The harvested volume after 3 years (root collar diameter 50 mm) was 10.5 tons, which falls short of the target amount of biomass is 20~30 ton/ha. In addition, the biomass amount of diameter 90 and 110 mm which reached the target amount were estimated to be 23.5 and 32.5 ton/ha respectively. As a result of experiment, it was found out that power of 128.2 and 175.8 W are consumed in case of cutting with the feed rate of 0.41m/s and minimum sawing speed (800 rpm) respectively. With the working area of 0.3 ha/h, it is considered to present working capacities of 16.5 and 22.8 ton/h respectively. The power consumed at the feed rate of 1.25 m/s is estimated to be 113.8 and 153.7W respectively and working capacity in a working area of 1 ha/h is estimated to be 23.5 and 32.5 ton/h. The power consumed at the feed rate of 2.5 m/s is estimated to be 119.8 and 166.9 W respectively and working capacity in a working area of 2 ha/h is estimated to be 47.0 and 65.5 ton/ha respectively. Therefore, the power source of harvest machine at the feed rate of 1.25, 2.50 m/s and sawing speed of 800 rpm shall be selected as it can process the target amount of estimated biomass.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Patient Satisfaction and Perception on Nutritional Counseling Services Quality (영양 상담서비스 품질에 대한 환자의 만족도와 인식조사)

  • Choi, Ki Bo;Lee, Song Mi;Lee, Seung Min;Lee, Eun;Park, Mi Sun;Park, Yoo Kyoung;Cha, Jin A;Lyu, Eun Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The objective of this study was to analyze patient satisfaction and perception of nutritional counseling services quality. A patient satisfaction and perception survey was conducted for 1,095 patients from 43 tertiary hospitals and 20 general hospitals. The number of returned questionnaires was 656 (response rate: 60.0%). Data from 633 questionnaires were analyzed after the questionnaires with unanswered items were excluded. Five domains were identified from the result of the factor analysis using the maximum likelihood and oblique rotation. The five domains were named empathy, responsiveness, tangibles, reliability, and skill and specialty. Patient perception mean score of nutritional counseling was 4.54/5.00. Patient satisfaction scores were significantly higher in empathy (P<0.001), responsiveness, and skill and specialty (P<0.01) with a college or graduate school education than in patients with a middle school education. There was no statistically significant difference between satisfaction scores in tertiary hospitals and those in general hospitals, but patients in capital hospitals reported significantly higher scores than their local counterparts in empathy, responsiveness, reliability, skill and specialty (P<0.001), and tangibles (P<0.05). In responsiveness, significantly higher (P<0.01) scores were observed in patients who received nutritional counseling only once compared to patients who received counseling two times. Patients perception of nutritional counseling services was significantly correlated with their satisfaction of five domains, reliability (r=0.721), responsiveness (r=0.697), empathy (r=0.690), skill and specialty (r=0.678), and tangibles (r=0.622).

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Resistance and Susceptibility of Diamondback Moth, Plutella xylostella Strains Collected from Different Region in Korea to Bacillus thuringiensis (국내 지역별 채집계통 및 감수성계통 배추좀나방에 대한 Bacillus thuringiensis 제품의 생물활성 비교)

  • Kim, Young-Rim;Cho, Min-Su;Oh, Se-Mun;Kim, Sung-Woo;Youn, Young-Nam;Yu, Yong-Man
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.2
    • /
    • pp.123-132
    • /
    • 2010
  • Six populations of the diamondback moth, Plutella xylostella, were collected from the different national areas for resistance and reared in laboratory for two sensitive population. These populations of P. xylostella were examined the developed resistance against commercial products of Bacillus thuringiensis. There were 3 products with B. thuringiensis subsp. kurstaki including Tyuneup$^{(R)}$, Thuricide$^{(R)}$ and Geumulmang$^{(R)}$ and 2 products with B. thuringiensis subsp. aizawai including Tobagi$^{(R)}$ and Scorpion$^{(R)}$. The sensitive population of diamondback moths were provided from National Academy of Agricultural Science (NP) and Highland Agriculture Research Center (GR population) and field populations were caught from 6 different national areas. Resistance against Tyuneup$^{(R)}$ was developed 4.8 and 2.5 times in SP and HS compared with GR population of diamondback moth, respectively. In case of Geumulmang$^{(R)}$, it was developed 9.9 and 6.8 times in SP and NM population compared with NP population, respectively. Otherwise, Tobagi$^{(R)}$ was showed higher resistance in HS than any other population compared with GR population, however, Scorpion$^{(R)}$ that is a same strain with Tobagi$^{(R)}$, was showed only double resistance to SP population. It was supposed that the development of resistance to B. thuringiensis might be caused by the continuous application of the specific commercial product at the specific area. So, we need to use the commercial products of B. thuringiensis in rotation with different B. thuringiensis strains. In the other hand, when HS population with highest resistance were reared in laboratory, their resistance ratio was rapidly dropped to 1.1 times at second generation. We have to examined the resistance mechanism of the diamondback moth to B. thuringiensis strains.